User manual 3R SYSTEM CASE R110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual 3R SYSTEM CASE R110. We hope that this 3R SYSTEM CASE R110 user guide will be useful to you.

Lastmanuals help download the user guide 3R SYSTEM CASE R110.


Mode d'emploi 3R SYSTEM CASE R110
Download
Manual abstract: user guide 3R SYSTEM CASE R110

Detailed instructions for use are in the User's Guide.

[. . . ] · Take care not to be scratched with sharp edges while installing this product to your system. · Tenga cuidado de no usar herramientas afiladas o puntiagudas mientras instala este producto en su equipo. · This product is intended for the use with a personal computer only. Use of this product in other applications voids all warranties. [. . . ] Este tipo de intentos eliminarán su garantía. . · While installing this product, please be sure that the tubes are not folded or twisted, so as to not hinder normal flow of the liquid, as reduced flow rate will lower the performance and continual overload on the pump motor may result in a breakdown of the motor eventually. · Mientras instale el producto, por favor, asegúrese de que los tubos no estén doblados o enroscados, esto podría dificultar el flujo normal del líquido. La reducción del flujo producirá un menor rendimiento del producto así como una continua sobrecarga en el motor de la bomba, que podría dar lugar a la ruptura de su producto. . · Do not drop this product or apply impact upon it. This may damage the product or cause leakage. · No golpee ni deje caer el producto. Esto podría dañarlo o producirle alguna fuga. · If you have questions about the installation or operation of the product, please visit our website (www. 3rsystem. co. kr). · Si tiene alguna pregunta sobre la instalación o la forma de operar de su producto, por favor, visítenos en nuestra página web . · We, 3R SYSTEM, cannot provide after-sale service for a problem or damage which resulted from not following the instructions in this manual. WCL02 water cooler is designed to best perform when cooling one CPU only. Careful setup is required for the extended cooing applications for GPU and another chipset since cooling effect resulting from the variation may vary, sometimes greatly, according to the system specifications. , External 120mm Radiator CPU, GPU, . Coolant Flow Example ( ) www. 3rsystem. co. kr www. rbox. co. kr 1 (Basic Setting) RADIATOR FAN (AIR) No. CPU TANK & PUMP Cooling Effect CPU ( High effect ) VGA > CPU Chipset > CPU VGA > Chipset > CPU CPU > Chipset CPU > VGA CPU > VGA > Chipset VGA CHIPSET 1 2 2 4 RADIATOR FAN (AIR) 3 VGA CHIPSET CPU TANK & PUMP 3 4 5 OPTIONAL PARTS 6 5 7 RADIATOR FAN (AIR) 7 6 CPU VGA CHIPSET TANK & PUMP OPTIONAL PARTS Water Block Installation Direction ( ) CPU . . Coolant OUT Coolant IN Coolant OUT Coolant IN Coolant IN Coolant IN Coolant OUT Coolant OUT II-3. WCL02 INSTALLATION EXAMPLE ( II-2 Coolant Flow N04 : Example ) PC PC . STEP 1 : WCL02 INSTALLATION - FITTING ASSEMBLY Parts . . 1 1 2 3 4 STEP 2 : WCL02 INSTALLATION ­ TUBE CUTTING ( EXAMPLE FOR STANDARD ATX CASE ) . ATX . 1 3 1 5 4 2 Radiator Pump Unit Pump Unit CPU Water Block CPU Water Block Chipset Water Block Chipset Water Block VGA Water Block VGA Water Block Radiator 250mm 350mm 180mm 200mm 150mm 2 3 4 5 STEP 3 : WCL02 INSTALLATION RADIATOR - PUMP UNIT : TUBE FITTING STEP 4 : WCL02 INSTALLATION PUMP UNIT ­ CPU WATER BLOCK : TUBE FITTING ( ) Parts Parts STEP 5 : WCL02 INSTALLATION 1. CPU Water Block - Chipset Water Block : Tube Fitting 2. Chipset Water Block -VGA Water Block : Tube Fitting 3. VGA Water Block - Radiator : Tube Fitting . . STEP 6 : WCL02 INSTALLATION First Coolant Injection : 130cc (approx. ) PC Power OFF 130cc . [. . . ] No Overly Bent Tube, Smooth Flow ( ) 4. Secure Settling of CPU/VGA/Chipset Water Block ( ) CHECK LIST 3 Parts II-4. WCL02 SERIES TROUBLESHOOTING ( ) www. 3rsystem. co. kr (SYMPTOM) LOW COOLING PERFORMANCE www. rbox. co. kr (POSSIBLE CAUSES) 1. CPU Insecure Mounting of the Water Block on CPU 2. Water Block Mounted in Wrong Direction 3. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE 3R SYSTEM CASE R110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual 3R SYSTEM CASE R110 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag