User manual A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE. We hope that this A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE user guide will be useful to you.

Lastmanuals help download the user guide A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE.


Mode d'emploi A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE
Download
Manual abstract: user guide A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE

Detailed instructions for use are in the User's Guide.

[. . . ] Omnicron 9000 series Installation and programming Instructions Default settings on power up User code 1234 Part set code 0000 Engineer code 9999 Cleaner code 7777 Exit time 30sec Entry time 30sec Bell Time 20min Speaker time 20min User reset YES Relay activation in part set YES Mains LED OFF (when armed) PA (sounder & relay) NOT SILENT Auto re-arm YES Bell delay OFF (0sec) Speaker delay OFF (0sec) Zone 1 E/E in part set YES Intermediate zones NONE Part set zones NONE Self-monitoring zones NONE Double knock NO To Enter ENGINEER MODE Press Reset key and enter current user code (1234) Then press program. code (9999) Red ENGINEER LED will flash continuously, indicating the panel is in engineer mode. YOUR NOW IN ENGINEER MODE. Downloaded from: http://www. guardianalarms. net If a mistake is made in programming, press the RESET key twice and start again. [. . . ] will still operate the communicator relay) AUDIBLE P. A. (factory set at all sounders) In ENG MODE Enter 01 (sounders now ON) ENGINEER RESET ONLY In ENG MODE Enter 15 CUSTOMER RESET In ENG MODE Enter 05 PROG. ENGINEER CODE In ENG MODE Enter 41 Four led's lit Enter new code TO PROGRAMME A ZONE THAT CUSTOMER CANNOT OMIT In ENG MODE Enter 47 Then the zone no. The respective led will light as each zone is entered. Re-enter 47 TO ENABLE CUSTOMER TO OMIT ZONES PREVIOUSLY INHIBITED In ENG MODE Enter 47 Then the zone no. The respective led will go out as each zone is entered. Re-enter 47 TO PROGRAMME ACCESS ZONES In ENG MODE Enter 42 then the zone number(s) that are required. As a zone is entered that zone led will light. TO REMOVE ACCESS ZONES As above enter 42. then the zone number(s) that are required. As a zone is entered that zone led will go out. SOAK TEST ZONES In ENG MODE Enter 45 then the zone number(s) that are required. As a zone is entered that zone led will light. REMOVE SOAK TEST ZONES In ENG MODE Enter 45 then the zone number(s) that are required. [. . . ] DE-ACTIVATE PART SET ZONES In ENG MODE Enter 44 then the zone numbers that are required. As a zone is entered that zone led will go out Enter 44. The zones led will go out PART SET EXIT ZONE 1 (TIMED) In ENG MODE Enter 17 Zone 1 is now part set exit REMOVE PART SET EXIT ZONE 1 (TIMED) In ENG MODE Enter 17 Zone 1 is NOT now part set exit COMM RELAY ACTIVE IN PART SET In ENG MODE Enter 06 Relay is now active in part set COMM RELAY NOT ACTIVE IN PART SET In ENG MODE Enter 06 Relay is now NOT active in part set COMM RELAY ACTIVE IN PART SET In ENG MODE Enter 16 Relay is now active in part set MAINS LED ON OR OFF WHEN ARMED In ENG MODE Enter 03 (led on when armed) Or Enter 13 (led off when armed) Press reset, reset to exit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual A1 SECURITY OMNICRON 9000-INSTALLATION-QUICK REFERENCE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag