User manual ACER ALTOS S205F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACER ALTOS S205F. We hope that this ACER ALTOS S205F user guide will be useful to you.

Lastmanuals help download the user guide ACER ALTOS S205F.


Mode d'emploi ACER ALTOS S205F
Download

You may also download the following manuals related to this product:

   ACER ALTOS S205F INSTALLATION GUIDE (166 ko)

Manual abstract: user guide ACER ALTOS S205F

Detailed instructions for use are in the User's Guide.

[. . . ] Altos S205F / S200F User's Manual Issue 1. 0 1 May, 2004 · Acer and the Acer logo are registered trademarks of Acer Incorporated. Other company's product names or trademarks are used herein for identification purposes only and belong to their respective companies. · All other names, brands, products or services are trademarks or registered trademarks of their respective companies. Notices Changes may be made periodically to the information in this publication without obligation to notify any person of such revision or changes. Such changes will be incorporated in new editions of this manual or supplementary documents and publications. [. . . ] When ON this LED denotes that incoming FC signal is GOOD. Host Port 1 Signal Good Host port 0 Signal Good Table 1­4 LED FC Host Port 0 Signal Good FC Host Port 1 Signal Good Router Status Module Fault Green Green Altos S200F JBOD I/O Module LEDs Definition Incoming FC signal is GOOD. No connection or incorrect connection Invalid SFP connection Not used. Color Green Normal Status On Off Flashing Green On Off Flashing Storage Router Device Ready Green Storage Router Device not ready or defective Fault present (also On when booting) Successful JBOD I/O module initialization Amber On Off Off On Fault Status 9 Altos S205F / S200F User's Manual Figure 1­9 Altos S205F RAID I/O Module The Altos S205F RAID I/O Module operates at 1 or 2 Gb/s. · One external port for expansion to further enclosures is provided by an SFP connector · Two external ports to the host controllers are provided from the RAID I/O Module with Form Factor (SFP) GBIC modules, auto-bypass at the output ports is provided. · An RJ45 10/100 Base T Ethernet controller management port is provided on the LRC board, interfacing to the controller through 2 RS232 serial and GPIO lines. Caution The RJ45 Ethernet connector on the LRC module must not be connected to telecommunications networks. · The RAID I/O Module also incorporates a standby Li-ion battery pack, 72 hours cache hold up time (512MB), or 60 hours cache hold up time (1GB). The battery cell has thermal protection and is connected to the RAID I/O Module by flying lead. not used Figure 1­10 Altos S200F JBOD I/O Module 10 Introduction Figure 1­11 Altos S205F / S200F Storage System Enclosure with I/O Modules and AC PSUs Installed 1. 3. 4 Supported Configuration Tools · RAIDWatch · R232 Management User Interface (MUI) 1. 3. 5 Drive Carrier Module The Drive Carrier Module comprises a hard disk mounted in a carrier. Each drive bay will house a single Low Profile 1. 0 inch high, 3. 5 inch form factor disk drive in its carrier. The carrier has mounting locations for SATA drives. Each disk drive is enclosed in a die-cast aluminum carrier which provides excellent thermal conduction, radio frequency and electro-magnetic induction protection and affords the drive maximum physical protection. The front cap also supports an ergonomic handle which provides the following functions: · Camming of carrier into and out of drive bays. · Positive 'spring loading' of the drive/backplane connector. · An anti-tamper lock operated by a torx socket type key. 11 Altos S205F / S200F User's Manual Figure 1­12 Drive Carrier Module 1. 3. 5. 1 SATA Transition Card For Serial ATA use a Transition card is attached to the rear of each drive, this provides a SCA-2 interface to the drive carrier using the same pins as Fibre Channel. There is one Transition card providing 1. 5 Gb/s for standard Serial ATA drives. Transition cards provide two paths to each drive, thus improving system availability. 1. 3. 5. 2 Drive Status Indicators Each drive carrier incorporates two indicators, an upper (Green) and lower (Amber). In normal operation the green indicator will be ON and will flicker as the drive operates. 1. 3. 5. 3 Anti-tamper Locks Anti-tamper locks are fitted in the drive carrier handles (Figure 1­13) and are accessed through the small cutout in the latch section of the handle. These are provided to disable the normal `pinch' latch action of the carrier handle. 12 Introduction Figure 1­13 Anti-tamper Lock 1. 3. 6 Dummy Carrier Modules Dummy carrier modules are provided for fitting in all unused drive bays. They are designed as integral drive module front caps with handles and must be fitted to all unused drive bays to maintain a balanced airflow. 1. 3. 7 Blank Modules Warning Operation of the Enclosure with ANY modules missing will disrupt the airflow and the drives will not receive sufficient cooling. It is ESSENTIAL that all apertures are filled before operating the unit. Dummy Carriers and/or Blank modules are available for this purpose. 1. 4 Visible and Audible Alarms The functional modules have associated status LEDs. The Ops Panel shows a consolidated status for all modules. LEDs show constant green for good or positive indication. Constant Amber LEDs indicate there is a fault present within that module. The Ops Panel also incorporates an Audible Alarm to indicate when a fault state is present and also an Alarm Mute push-button. Warning The Ops Panel is an integral part of the enclosure chassis assembly and can only be replaced by trained personnel. 13 Altos S205F / S200F User's Manual 1. 5 Altos S205F / S200F Storage System Technical Specification 1. 5. 1 Dimensions Rack Enclosure Height Width across mounting flange Width across body of enclosure Depth from flange to rear of enclosure body Depth from flange to maximum extremity of enclosure (rear hold down) Depth from flange to furthest extremity at front of unit Depth overall Tower Enclosure Height Width (including mounting feet) Depth inches 5. 1 19 17. 6 21 21. 7 0. 5 22. 2 inches 22. 27 10. 22 23. 24 millimeters 130 483 447 531 550 13 563 millimeters 501 230 523 Table 1­5 Altos S205F / S200F Storage System Chassis Dimensions 14 Introduction 1. 5. 2 Weight Maximum Configuration Empty Enclosure (Rack) PSU/Cooling Module Controller I/O Module Tower Conversion Kit Rack mount: Tower: 37kg (81lb) 40kg (88lb) 9kg (19. 8lb) 4kg (8. 8lb) 0. 9kg (1. 98lb) 3kg (6. 6lb) 1. 5. 3 AC Power (450W PSU) Voltage Range Voltage Range Selection Frequency Inrush Current Power Factor Harmonics 100-120 / 200-240 VAC Rated Automatic 50/60 Hz 50A @ 260VAC >0. 98 Meets EN61000-3-2 1. 5. 4 PSU Safety and EMC Compliance Safety Compliance UL 60950 IEC 60950 EN 60950 EMC Compliance CFR47 Part 15B Class A EN55022 EN55024 1. 5. 5 Power Cord (minimum requirements) Cord Type Plug Socket SV 0r SVT, 18 AWG minimum, 3 conductor 250V, 10A IEC 320 C-14, 250V, 15A 15 Altos S205F / S200F User's Manual 1. 5. 6 Environment Table 1­6 Ambient Temperature and Humidity Temperature Range Operational NonOperational Storage Shipping 5°C to 40°C 0°C to +50°C 1°C to +60°C -40°C to +60°C Relative Humidity 20% to 80% non-condensing Max. [. . . ] Chassis A sheet metal enclosure incorporating a Backplane PCB and module runner system. The chassis contains a number of 'Bays', each of which can accommodate a plug in module. There are sixteen drive carrier bays at the front and five bays at the rear which house two power supply/ cooling modules, two I/O modules and also the Ops Panel. Configure To set up a hardware device and its accompanying software. I/O module (Serial ATA RAID or JBOD I/O module) A plug-in module providing FC-AL channel external cable interface with 16 SATA drives. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACER ALTOS S205F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACER ALTOS S205F will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag