User manual ACR ELECTRONICS RCL-50

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACR ELECTRONICS RCL-50. We hope that this ACR ELECTRONICS RCL-50 user guide will be useful to you.

Lastmanuals help download the user guide ACR ELECTRONICS RCL-50.


Mode d'emploi ACR ELECTRONICS RCL-50
Download
Manual abstract: user guide ACR ELECTRONICS RCL-50

Detailed instructions for use are in the User's Guide.

[. . . ] CAUTION: Before proceeding to install, test or use your new ACR Electronics product, please read this Product Support Manual in its entirety. If you have questions regarding the contents of the manual, please contact our Technical Service Department at ACR Electronics, Inc. , Telephone +1 (954) 981-3333 or email service@acrelectronics. com. Please be ready to provide the technician with the page number you wish to discuss. If you have a question that is not covered in the manual, please visit our website and access the Frequently Asked Questions (FAQs) section for further information or call our Technical Service Department. [. . . ] An LED blinking red / green indicates that the XRCiZTM feature is now "exercising" the Searchlight. NOTE: XRCiZTM feature is only available when paired with a URC-102 Master Controller. Y1-03-0141D 7 Figure 4- URP-102 Point PadTM Surface Mount Case Figure 5- URP-102 Point PadTM Flush Mount Case Y1-03-0141D 8 Figure 6- URP-102 Point PadTM Surface Mount Case with gasket and Flush Mount Case with gasket SECTION 6- URC-102 Master Controller Mounting The Master Controller can be mounted in any position near the searchlight that is protected from the weather. Check in advance that the coax cable from the Point PadTM and the wiring harness from the searchlight can be routed to this location. Mount the Master Controller with the wires and coax facing down. Use an appropriate fastener for your mounting location. Use a sealant in fastener holes to prevent moisture intrusion. General wiring scheme The RCL-50B has a unique wiring scheme. Special attention must be paid to the following chart. The Master Controller is supplied with an in-line fuse-holder on the orange power lead. Use only 15 amp fuses in this fuse-holder. See Figure 9 for the master controller wiring diagram. WARNING: Failure to follow this arrangement may damage components. Master Controller Wire Orange Blue Yellow Green Red White Black Brown Searchlight Cable Wire Power Source Lead +12 VDC or +24 VDC** Ground Yellow Green Red White Black Brown Function Power Ground Lamp Power Lamp Ground Up Down Right Left Table 1 Y1-03-0141D 9 WARNING: This wire MUST be fused with a 15 amp fuse in the Master Controller's in-line fuse-holder. Wiring to Searchlight The RCL-50B searchlight is supplied with a 12-foot integral wire harness. This wire harness is cut to this length specifically to allow for a voltage drop. Shortening the harness will decrease the life of the bulbs. Any extra length of wire harness should be loosely coiled in a convenient place. For best performance, the controller should be attached to the end of the 12' searchlight wire harness. If you must lengthen the wire harness, use heavy duty wire to minimize the voltage drop. This is especially important for the yellow lamp power and green lamp ground wires. Following the wiring scheme shown in Table 1 use the supplied butt connectors to connect the master controller to the searchlight. Wiring to Point PadTM The RG-59 coax cable is supplied without the "F" connectors attached for ease of routing. After the coax has been routed, strip the insulation and crimp the "F" connectors in place. Screw the "F" connectors to the master controller and the Point PadTM. Wiring to Power Supply The power source must be a fused 12 VDC, 5-amp supply or 24 VDC, 3-amp supply. Following the wiring scheme in Table 1, use the supplied butt connectors to connect the Master Controller to the power source. Refer to Table 2 for proper wire size for connection of the input power lines. [. . . ] will repair or, at its option, replace the unit at no cost to you for labor, materials and return transportation from ACR. For further assistance, please contact our Technical Service Department at ACR Electronics, Inc. , 5757 Ravenswood Road, Fort Lauderdale, FL 33312-6645. Email: service@acrelectronics. com, Fax: +1 (954) 983-5087, Telephone: +1 (954) 9813333. This warranty does not apply if the product has been damaged by accident or misuse, or as a result of service or modification performed by an unauthorized factory. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACR ELECTRONICS RCL-50

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACR ELECTRONICS RCL-50 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag