User manual ACT ACTPRO 1000 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACT ACTPRO 1000. We hope that this ACT ACTPRO 1000 user guide will be useful to you.

Lastmanuals help download the user guide ACT ACTPRO 1000.


Mode d'emploi ACT ACTPRO 1000
Download

You may also download the following manuals related to this product:

   ACT ACTPRO 1000 PART 1 (1442 ko)
   ACT ACTPRO 1000 PART 2 (1630 ko)
   ACT ACTPRO 1000 INSTALLATION (511 ko)

Manual abstract: user guide ACT ACTPRO 1000DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] [. . . ] The LCD display and backlit keypad facilitate ease of use for the installer and system administrator. The ACTpro 1000 operates in Standalone mode or may networked to a PC using the ACTWin pro application. Card access door controller Main Features Single door controller The ACTpro 1000 may be in turn networked with other ACTpro 1000s to create a network of up to 256 doors RS485 interface to network controllers 10, 000 users 16 user groups 16 time zones Entry and exit reader support 500 event log 1000 user codes (Pin Only) 220/240 Volts AC ACTpro 1000 Installation / Specification Guidelines PSU The ACTpro 1000 requires a 12 volt dc supply The controller may not be installed outdoors unless it is in a sealed and heated cabinet The ACTpro 1000 controller may be networked via RS485 to expand the system up to 256 doors maximum The maximum amount of ACTpro 1000s per RS485 output is 32 (ACT supply a 4x485 or 1x485 interface for PC networks) The ACTpro 1000 is compatible with ACTWin pro and ACTWin pro Lite software packages The ACTpro 1000 will operate standalone or can be connected to a PC For comparisons to our other controllers please check the comparison chart on the back page EXIT 3 Inputs (100mA) Tamper 12/24 Volts DC 8 Core Screened 5 Amp Lock Output 3 Outputs (100mA) ACTpro 1000/2000/3000 Controllers and ACTpro 100 expander require a 12 volts DC supply ACTpro 1000 System Schematic ACTpro 1000 Product Specification Card access door controller Operating Voltage: Current Consumption: Weight: Operating Temperature: Dimensions (HxWxD): Mounting: 12 Volts DC 40 - 150 mA 750 grams 0 to +50 C 138 x 87 x 37 mm Surface or Flush ACTpro 1000 Controller Cabling Chart From Reader ACTpro products comparison chart Cable 8 core screen Twisted screen pair or Cat 5 Twisted screen pair or Cat 5 Cable supplied To Controller Restriction 30m at 5volts 100m at 12volts Maximum 30m Feature Doors Users User Groups Time Zones Event Log Anti passback Timed anti passback ACTpro 1000 1 10, 000 16 16 500 ACTpro 2000 2 20, 000 1000 128 5000 Yes ACTpro 3000 2 30, 000 1000 256 5000 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp 1 amp 2 (100 mA) 2 (100 mA) Yes 2, 000 max Yes Yes Yes 10 Base-T (RJ45) ACTpro 1000 PC Direct RS232 ACTpro 1000 Network RS485 interface PC Maximum 1. 4km Entry and exit reader support Timed actions Interlock Intruder Alarm System Integration User tracking Clock & Data or Wiegand auto detect Card only operation Card or pin Yes Yes Yes Yes Yes Yes Yes Yes Network RS485 interface Maximum 30m Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp 2 (100 mA) 2 (100 mA) Yes 256 max Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp 1 amp 2 (100 mA) 2 (100 mA) Yes 2, 000 max Yes Yes Ordering Information Controller Single channel RS485 interface Four channel interface 56k modem ACTpro 1000 ACT Net IF-1 (requires 12v DC supply) ACT Net IF-4 (Built in PSU) ACT 56K modem Card and pin Auxiliary door operation Door monitoring Door control DDA extended timer facility Backlight Automatic daylight saving adjustment Fire alarm override Toggle mode Door relay output Auxiliary relay output Card Readers Specifications The ACTpro 1000 will work with the full range of ACT card readers as well as most industry standard readers with clock & data or wiegand outputs. Programmable inputs Programmable Outputs Tamper & low voltage output Network doors Modem connection Built in TCP/IP TCP/IP compatible Ethernet Network Interface 56k Modem 4 channel RS485 Interface Single channel RS485 Interface Access Control Technology Unit C1, South City Business Park, Tallaght, Dublin 24, Ireland. [. . . ] [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTPRO 1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACTPRO 1000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag