User manual ACT ACTPRO 3200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACT ACTPRO 3200. We hope that this ACT ACTPRO 3200 user guide will be useful to you.

Lastmanuals help download the user guide ACT ACTPRO 3200.


Mode d'emploi ACT ACTPRO 3200
Download

You may also download the following manuals related to this product:

   ACT ACTPRO 3200 DATASHEET (1783 ko)

Manual abstract: user guide ACT ACTPRO 3200

Detailed instructions for use are in the User's Guide.

[. . . ] · ACTpro 200 2 Door controller door station. · Connection to PC over TCP/IP or RS232/RS485. · 3 Amp Regulated Power Supply with battery backup provision. · Steel Cabinet (thickness 1. 2mm) with hinged lid. [. . . ] A protective EARTH must be provided for safety in accordance with EN61010 Part 1 : 1993 : Clause 6. 5. 1. An appropriate Mains Isolation switch (Mains on/off) should be fitted between the AC input of the unit and the equipment electrical supply plug to allow equipment servicing. Before any maintenance of the product, ensure mains is disconnected. · · · · · Ordering Information Model ACTpro 3200 Description 4 door controller & 12 V DC 3amp power supply Part Number ACTpro 3200 2 ACTpro 3200 Operating and Installation Manual Rev 1. 0 Power Budget Calculation The power supply output is 12 Volt DC supplying a max of 3amps. This is sufficient to power the ACTpro 3200 and up to 8 readers and the battery recharge. ACT recommends the use of a separated power supply for the locks. The power budget calculation below shows that when all the 4 doors of the ACTpro 3200 are used with ACTpro-X Entry and Exit readers that the total current consumption is 2000mA. This gives headroom of 1000mA. Item ACTpro 3200 Door 1 Entry ACTpro-X Reader Door 1 Exit ACTpro-X Reader Door 2 Entry ACTpro-X Reader Door 2 Exit ACTpro-X Reader Door 3 Entry ACTpro-X Reader Door 3 Exit ACTpro-X Reader Door 4 Entry ACTpro-X Reader Door 4 Exit ACTpro-X Reader Battery 1 Recharge current Battery 2 Recharge current Safety Margin Total Headroom Current(mA) 460 80 80 80 80 80 80 80 80 300 300 300 2000 1000 Battery Back Up · · · · · After a mains power failure the ACTpro 3200 will continue to operate while the batteries have a sufficient charge. There is room in the cabinet for two 7Ahr batteries giving a total of 14Ahrs. The length of time these batteries will last depends on the power consumption. Battery 2 can be used if a longer operation time without a mains supply is required. Battery 1: · · · By default Battery 1 is used to provide the backup power to the ACTpro 3200 and all the readers. The duration for which the battery can provide backup power can be calculated by dividing the battery rating by the total current draw. In the example from the power budget above the total current draw is 1100mA or 1. 1A. This figure is calculated by the ignoring the recharge currents which don't apply when the battery is supplying the current and ignoring the Safety margin which is obviously not a current draw. Given a battery capacity of 7Ahr and the calculated current draw of 1. 1A. Then the battery will last for 7/1. 1 = 6. 36 Hrs · 3 ACTpro 3200 Operating and Installation Manual Rev 1. 0 Battery 2: · · · · · The second battery maybe used to provide a longer battery backup period. In this case the ACTpro 3000 should be connected to the OUTPUT 2 supply. Battery 1 will power the ACTpro 200 and 4 readers. Battery 2 will power the ACTpro 3000 and 4 readers. [. . . ] Apply mains power (mains should be connected by a qualified installer) 12. Check that the controller does not report any door offline. Ensure there are no faults reported on the controller display. For ACTWin pro users, make sure the Mains Fault box is ticked for the ACTpro 3200 doors 3 & 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTPRO 3200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACTPRO 3200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag