User manual ACT ACTPRO 4000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACT ACTPRO 4000. We hope that this ACT ACTPRO 4000 user guide will be useful to you.

Lastmanuals help download the user guide ACT ACTPRO 4000.


Mode d'emploi ACT ACTPRO 4000
Download

You may also download the following manuals related to this product:

   ACT ACTPRO 4000 DATASHEET (509 ko)

Manual abstract: user guide ACT ACTPRO 4000

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and Installation Instructions for the ACTpro 4000 Access Control System 18-00071 ACTpro 4000 Operating Instructions 1. 00 __________________________________________________________________________ Contents About ACTpro 4000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Operating Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · The Keypad Beep option forces the keypad to make a short beep in response to any key being pressed. · The Show Status option enables the displaying of continuous door status on the display. · The Show Events option enables the displaying of events on the display as they occur. · The Tech Bleep option specifies that the ACTpro 4000's onboard buzzer will sound intermittently if a technical fault (mains, tamper or door offline) condition exists. Language The ACTpro 4000 display supports the following languages English, Polish, French, Spanish, Dutch and Italian. The language is selected from this menu. __________________________________________________________________________________ 20 ACTpro 4000 Operating Instructions 1. 00 __________________________________________________________________________ PIN Length The length of PIN codes used in PIN Only and PIN & Card modes may be set between 4 and 9 digits. If a PIN length greater than six is set, then the length of the operator and installer codes will increase to this length. (Leading zeros added to PIN). Fire Doors This function allows a group of doors (or all doors) to be configured for fire override. A 0Volt signal from a fire alarm (or other) system is applied to the AUX input on door 1. When the 0Volt signal is removed, the selected doors are held open until the 0 Volt signal is re-applied. Typically, a normally-closed relay on the fire panel, with the common connected to 0 Volts, is used for this purpose. Please note that this facility is present for convenience only, it does not remove the need to have an alternate mechanical means of escape. User Tracking · Doors may be defined as Perimeter doors by pressing the key so that the door number is displayed. Those not defined as a Perimeter door are displayed as -. Users that enter through a perimeter door are tracked but not restricted. Tracking of a user means it is logged if the user is in the tracking area or not. Entering through any perimeter doors logs the user into the area. Exiting any perimeter door logs the user out of the area. Note: If either Anti-passback or Timed Anti-passback doors are defined then perimeter doors are ignored. · Doors may be defined as Anti-passback doors by pressing the key so that the door number is displayed. Those not defined as Anti-passback doors are displayed as -. The Anti-passback doors define the tracking area. Users are allowed entry to the area only if they have previously exited. · Doors may be defined as Timed Anti-passback doors by pressing the key so that the door number is displayed. [. . . ] Enter the installer Menu and select the Door Settings submenu. Then select the Door number of the reader that User will arm and disarm from. In the Alarm section of Door Settings set the "ARM Intruder" option to Yes. If the Alarm Panel provides a signal to indicated the arm/disarm status then in the Operation section of the Door settings set the "Monitor Arming" Option to Yes If the alarm panel does not provide a status signal then ensure the "Monitor Arming" option is set to No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT ACTPRO 4000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT ACTPRO 4000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag