If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ACT CONFIGURING ACTPRO200. We hope that this ACT CONFIGURING ACTPRO200 user guide will be useful to you.

Lastmanuals help download the user guide ACT CONFIGURING ACTPRO200.


Mode d'emploi ACT CONFIGURING ACTPRO200
Download
Manual abstract: user guide ACT CONFIGURING ACTPRO200

Detailed instructions for use are in the User's Guide.

[. . . ] Remember to connect the supplied varistors across the door lock terminals. Set the dipswitch on the ACTpro200 to the desired address. The doors are numbered in sequence, so if the dipswitch address is set to 7, then door 1 will report as 7 and door 2 will report as 8. [. . . ] Check that cards/PIN codes grant access and open the doors. 1 Use ACTWinPro 2. 2 or later with the ACTpro200. Always connect Battery 1 to the ACTpro200. Battery 2 is not required if nothing is powered from Output 2. Monitoring of Battery 2 may be disabled by setting Dipswitch 3 to ON. www. accesscontrol. ie +353 1 466 2570 ACTpro200 2 Door Station & Power Supply ____________________________________________________________________________________ AC AC E 12V 0V 12V 0V 12V 7AHr 12V 7AHr Features This product consists of a 2-door controller housed inside a metal cabinet, complete with a monitored power supply. The unit is designed to connect to ACT2000 and ACT3000 controllers on the Door Station RS-485 network. The assembly as supplied provides the following features: · 18 swg Mild Steel Cabinet with hinged lid with space for 2 7Ahr batteries · 3 Amp Power Supply with battery backup provision (Batteries not supplied) · Monitored power supply with automatic battery test · 2 fused outputs for door locks · PSU status (AC fault, battery low ) reported to controller and to ACTWinPro · Deep-Discharge protection of batteries provided · 20mm `knockouts' provided for external wiring at top and sides · 7 40mm holes in the back of the cabinet for rear wiring entry · Wiring Instructions on label inside front lid. · Lid to accommodate two standard DS100 units www. accesscontrol. ie +353 1 466 2570 Power Supply Specification The power supply is capable of supplying a maximum of 3 Amps. This should be sufficient to power the 2-Door Station pcb, up to 4 readers, 2 locks and provide charging current for the batteries. Use the following table to ensure you do not overload the power supply: Item Current(mA) DS200 100 Door 1 Entry Reader 80 Door 1 Exit Reader 80 Door 2 Entry Reader 80 Door 2 Exit Reader 80 Door 1 Mag Lock Door 2 Mag Lock Battery 1 Recharge current 300 Battery 2 Recharge current 300 Safety Margin 300 Total The total current should not exceed 3Amps (3000mA). This leaves approximately 1600mA available for supplying the locks on a 2 door system with 2 entry and 2 exit readers. Battery Backup There is room in the cabinet for two 7Ahr batteries giving a total of 14Ahrs. The length of time these batteries will last depend on the power consumption of the system. Battery 1 provides backup for the PCB, the readers and Door 1 output. Battery 2 provides backup for Door 2 output only. A magnetic lock draws current continuously and therefore you can add the continuous current to the total. A fail-safe lock (door strike) only draws current when it operates. In this case you need to estimate the average hourly consumption using the following equation: Lock Current (mA) x (Number of operations per hour x door relay time)/3600 For example, a 500 mA lock operating 20 times an hour for 5 seconds would use 500 x (20 x 5)/ 3600 = 13. 9mA per hour Once the total power consumption has been determined, then it can be calculated how long the batteries will last. Example DS200 with two readers and 2 magnetic locks, each drawing 400mA would consume www. accesscontrol. ie +353 1 466 2570 100 + 80 + 80 + 400 + 400 = 1060mA. In the event of a power fail, Battery 1 will supply the pcb, readers and 1 lock. [. . . ] This unit is designed for use from an AC supply of between 195V min and 253V max. Mains power should be connected to the ACTpro200 by a licensed electrician in accordance with local and national codes For continued protection against fire hazard, replace fuses with the same type and rating. A PROTECTIVE EARTH must be provided for safety in accordance with EN61010 Part 1 : 1993 : Clause 6. 5. 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACT CONFIGURING ACTPRO200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ACT CONFIGURING ACTPRO200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag