User manual ADE 8SP 401 ACCENTA G3 INSTALLATION MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ADE 8SP 401 ACCENTA G3. We hope that this ADE 8SP 401 ACCENTA G3 user guide will be useful to you.

Lastmanuals help download the user guide ADE 8SP 401 ACCENTA G3.


Mode d'emploi ADE 8SP 401 ACCENTA G3
Download
Manual abstract: user guide ADE 8SP 401 ACCENTA G3INSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Intruder alarm system Engineering Information Power Power 1 2 3 4 5 6 7 8 0 1 6 Omit 2 7 Reset 3 8 Prog 4 PA Attack 5 Tamper Chime Day 9 Set ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 Tamper Attack 0 5 Chime 1 6 Omit 2 7 Reset 3 8 Prog 4 PA 9 Set Day Power Accenta 8SP 401 Accenta G3 panel with remote LED keypad 8EP 395 Optima G3 panel with built-in keypad 12345678 Power Attack Tamper Power Chime Omit Reset Prog Set 0 5 1 6 2 7 3 8 4 PA 9 Day ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 Tamper Attack 0 5 Chime 1 6 Omit 2 7 Reset 3 8 Prog 4 PA 9 Set Day Power Accenta Accenta/!mini 8SP 400 Accenta mini G3 panel with remote LED keypad 8EP 396 Optima compact G3 panel with built-in keypad The above intruder systems are designed to comply with the installation requirements of BS 4737 1986/87. This manual provides information on Installation design, panel fixing, wiring , power up and programming of the intruder panels. Engineering information Accenta/Optima G3 Intruder system Contents Features - - - - - - - - - - - - - - - - - - - 2 Installation Design - - - - - - - - - - - - - - 3 Fixing - - - - - - - - - - - - - - - - - - - - 3 Wiring the system - - - - - - - - - - - - - - 5 Tamper network - - - - - - - - - - - - - - - 5 Connect Remote Keypads / Lighting controllers 5 Security zones - - - - - - - - - - - - - - - - 5 Push to set zone - - - - - - - - - - - - - - - 6 Remote keyswitch zone - - - - - - - - - - - 6 Fire zone - - - - - - - - - - - - - - - - - - 6 PA circuit - - - - - - - - - - - - - - - - - - 6 Extension speaker - - - - - - - - - - - - - - 7 Bell Output (External sounder) - - - - - - - - 7 13V Supply output - - - - - - - - - - - - - - 8 Set - - - - - - - - - - - - - - - - - - - - - 8 Remote signalling Input and Outputs - - - - - 8 Filtering of Intruder alarms - - - - - - - - - - - 9 Features 8z MEM RKP PART SET 4 REMOTE 8 6 OUTPUT 5 09 SET ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ 8 zones, all programmable for Security, Fire, 24H Fire, PTS or keyswitch applications PA input Tamper input Outputs for Bell and Strobe 4 Access level Codes, User 1, User 2, Engineer and Duress, all programmable 3 fully selectable part set programs Chime on any zone 8 event memory Programmable timers including bell cut off Walk Test facilities Quick set feature Remote keypad with on board PA and illuminated keys standard for Accenta panels and Optional for Optima panels Option for connection of Lighting controllers Options to connect up to four remote keypads / Lighting controllers NVM for protection of engineer programme 6 digital outputs for a wire-in digital communicator, Red Care STU or dialler (Not applicable for Optima compact G3 panel) Service warning indicator, programmable between 100 and 800 set and unset events Battery capacity of up to : 2. 1Ah in Accenta/Optima G3 mini enclosure 7Ah in Accenta/Optima G3 enclosure Optima G3 and Optima G3 mini are supplied with built in keypad Factory set condition - First Power up - - - - Mains Connection - - Testing the system - - Engineer program mode - - - - - - - - - - - 10 11 11 12 12 12 12 12 12 13 14 14 14 15 16 17 17 18 18 19 20 21 22 23 24 25 27 27 28 To exit - - - - - - - - - - - - - - - - - - - - - 12 ÿ ÿ ÿ System indications - - - - - - - - - To enter Engineer program mode - - To Exit Engineer program mode - - To reset panel to Factory set conditions Access Codes - - - - - - - - - - - Programs - - - - - - - - - - - - - Zone Function per Program- - - - - Exit Modes program - - - - - - - - Programs 1, 2 and 3- - - - - - - - - Alarm and Walk tests - - - - - - - Communicator tests - - - - - - - - `Flag A' Options - - - - - - - - - - `Flag B' options - - - - - - - - - - Viewing the event log - - - - - - - Zone Type - - - - - - - - - - - - - Zone Attributes - - - - - - - - - - Bell and Service Timers - - - - - - Re-arm and Anticode reset code - - Lighting controller - - - - - - - - - Faults - - - - - - - - - - - - - - - Specification- - - - - - - - - - - - Servicing organisation Details - - - Parts - - - - - - - - - - - - - - - Quick Reference - - - - - - - - - - - Features 2 4PI175 issue 1_6/01 Accenta/Optima G3 intruder system Engineering information bell/sounders, strobes and detectors to ensure that this rating is not exceeded. Installation Design The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding and the follow the procedures and advice contained in this manual. Depending on which area you live, you may be required, by law to notify the Local Authority and Police of the new security alarm installation. The Plan the position of each part of local authority requirements may differ from the alarm system and the cable area to area, therefore, it is advisable to contact runs. [. . . ] Final Door A final door program will be Set 5 seconds after a timed zone has opened and closed. Silent Set This operates exactly the same as `Timed' but completely silent without the internal sounder signal. ÿ ÿ ÿ Program 1 : To arm all of the zones and become Set as the user leaves the property and closes the final door. Program 2 : To protect the perimeter of the property in the evening and become Set after say 20 seconds. Program 3 ; To protect the downstairs areas of the house at night and become Set instantly and silently. Programs Note: The above are purely examples. The installer must program the panel to configure all the circuits to the customer's exact requirements. Note: If a program is not selected when the user Sets the system, Program 1 will automatically Set. Therefore Program 1 is usually considered as the Full Set Program containing all of the zones. Zone Function per Program Timed : This function would be used to protect the main entry/exit door of the entry route. Time inhibited : This is a zone which, on setting the panel, allows access to the Entry / Exit zone. However, if the panel is set and an time inhibited zone is triggered before an Entry /Exit zone then an alarm will be generated immediately. Immediate: This is a zone which will, when entered, go into alarm when the panel is set. Unused : A zone that is programmed as an Unused zone by the Engineer, then is ignored by the panel. Primarily used for Part set options. 14 4PI175 issue 1_6/01 Accenta/Optima G3 intruder system Engineering information Programs 1, 2 and 3 Example: To configure Program 1 Exit mode to Final door set, Press: Prog 9 9 9 9 Prog 1 6 3 Reset Reset Reset Reset Enter Engineer program mode Prog Set up program Attack Zones 1, 2 and 3 0 1 2 Deselect all zones Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Appropriate Zone indicator is lit to show selected zones Zone n selected Zone n deselected Press number button to select Program to be configured 1 2 3 Program 1 Program 2 Program 3 Zone 1 Zone 2 Zone 3 3 Press number button to select / deselect zone 4 5 6 7 8 Factory defaults 1 2 3 4 5 6 Used Zones Timed Zones Time inhibit zones Entry time All Zones Day Zone 1 Day Zone 2 Day Input Entry/Exit time respectively Zone 1 0 0 0 1 10 seconds duration 2 20 seconds duration 3 30 seconds duration (factory default) Exit time Zone 2 Exit mode Day Day Factory default Press a number button to select the appropriate Exit mode Acknowledge 0 1 2 3 4 Disabled Timed Terminated set Final Door Set Silent set (use exit time) For Programs 2 and 3 Zone 1 for Program 1 Zone 2 Zone 3 Zone 4 Reset Exit to Program and complete used zone set up Exit to Setup program Exit Set up program Leave engineer mode Day Acknowledge Tamper Day Reset Day Reset Attack Reset 4PI175 issue 1_6/01 15 Programs 1, 2 and 3 Engineering information Accenta/Optima G3 Intruder system Alarm and Walk tests Example: To start bell test and thereafter to stop bell test. Prog 9 9 9 9 1 3 0 Reset Reset Enter Engineer program mode 1 Alarm test Attack Press zero to turn off options 2, 3, 4 and 5 before selecting a new one 2 Strobe test Strobe On Bell on Day Day 3 Bell test 4 Low volume sounder High volume sounder Walk test internal low volume sound internal high volume sound Strobe Day Day Alarm and Walk tests 5 6 Strobe On Day x1 for zone 1 x2 for zone 2 | x4 for zone 4 flat x1 for zone 5 flat x2 for zone 6 | flat x4 for zone 8 Rapid for PA Rapid for Tamper Appropriate zone lights are lit(latched) Zones Attack Tamper 0 OFF Day Reset Exit current level Attack Reset Leave engineer mode Day Acknowledge Tamper The alarm test function allows you to test the Strobe, Bell, Low and high volume sounders of the system. The walk test function allows each detector to be checked in order to verify that they are functioning correctly. 16 4PI175 issue 1_6/01 Accenta/Optima G3 intruder system Engineering information Communicator tests Note: These tests are not applicable to Optima compact G3 panel. Example: To test intruder output and thereafter stop the test. Prog `Flag A' Options Example: To set the panel for engineer reset, Press: Prog Reset 9 Reset 9 9 9 3 3 9 Reset 9 Reset 9 9 2 3 0 Enter Engineer program mode 3 Enter Engineer program mode Communicator Appropriate 2 Tests Zone indicator Attack is lit to show a selected output Factory defaults Flags A Attack Zones 1-8 Momentarily On Appropriate Zone indicator is lit to show flag setting Factory defaults Zone 1 1 Press number button to select / deselect flag setting Silent PA RKP PA enable Engineer reset Anti-code reset Enable Door bell on PTS Enable single key setting Enable strobe on setting Enable Bell in Fire Exit current level 1 Press number button to select / deselect test Fire Output PA Output Intruder Output Open /Close Output Abort Output Zone 1 2 3 4 5 6 7 8 Zone 2 2 3 4 5 Zone 2 Zone 3 Zone 3 Zone 4 Zone 4 Zone 5 Zone 5 6 Confirmed Output Communicator fault 0 Stop the tests Reset Zone 6 Zone 8 Zone 6 Zone 7 Exit current level Attack Zone 8 Reset Leave engineer mode Reset Attack Day Acknowledge Tamper Reset Leave engineer mode Day Acknowledge Tamper The Zone 8 LED is lit to show there is a communicator line fault. Flag A descriptions: Silent PA : When this flag is set and on operating PA will cause a Silent PA alarm. RKP PA Enable: When this flag is set the keypad PA buttons are enabled. Engineer Reset: When this flag is set an Engineer code must be entered to reset the system after a full alarm. When the flag is clear the system can be reset by the user. Anti-code Reset: When this flag is set it enables the anti code reset function. Enable Door bell on PTS: When this flag is set it allows a zone circuit programmed as PTS to operate as a door bell. Enable single key setting:When this flag is set it allows the panel to be set by pressing the SET button (ie code entry is not needed), however a 4 digit code is needed to Unset the panel. Enable strobe on setting: When this flag is set the external strobe will flash for 3 seconds once the panel has successfully set. Enable external Fire bell: When this flag is set the system bell will sound 3 seconds On / 3 seconds Off during a fire alarm. 4PI175 issue 1_6/01 17 Communicator tests Engineering information Accenta/Optima G3 Intruder system `Flag B' options Note: The following settings: Communicator output, Line Fail, Program 1, 2 and 3 to report are not applicable to Optima compact G3 panel. Example: To set the panel for user to reset PA, Press: Prog Reset Viewing the event log Example: To view up to 8 previous events and thereafter to stop the event scroll, Press: Prog 9 9 9 9 Chime Reset 9 Reset 9 9 9 4 3 Enter Engineer program mode Chime View the event log Enter Engineering program mode Appropriate 4 Flags B Zone indicator is lit to show Attack flag setting Zones 1-8 Momentarily On Factory defaults Zone 1 Tamper Automatic event scroll Starting from event 1 to 8 To manually scroll View event 1 1 (oldest event) 2 3 4 5 6 Zone, PA and Tamper indicators will be lit to show zone in alarm. Flashing indicates the first zone in alarm. Day indicates status of panel at the time of alarm 1 2 Press number button to select / deselect function Communicator output active high Line fail active high User Reset PA User Reset Fire Program 1 to report Program 2 to report Program 3 to report Entry deviate Exit current level Zone 2 View event 2 View event 3 View event 4 View event 5 View event 6 View event 7 `Flag B' options 3 4 5 6 7 8 Zone 3 Zone 4 Zone 5 Zone 6 7 Zone 7 Zone 8 Reset Attack 8 View event 8 (Newest event) Chime Resume automatic scroll Reset Leave engineer mode Reset Day Acknowledge Tamper Stop event scroll / view Leave engineer mode Day Acknowledge Tamper Tamper Flag B descriptions: Communicator output active high: When this flag is set it configures the polarity of communicator outputs to active high, that is output is held at 0V rising to 12V in alarm. [. . . ] For example if the alarm was set with a code, to Unset with the keyswitch, it would have to be momentarily turned to Set then returned to Unset. Faults during setting If the system is not clear when you try to Set it, the sounder will produce an open zone tone and the fault will be displayed. Either re-enter your code to turn off and investigate or omit the faulty zone(s) from the system. 4PI175 issue 1_6/01 3 How to set the system (on program 1) n n n n Operating instructions Accenta/Optima G3 Intruder system How to Quick set During the exit period (on entering User code) Day the system may be Set Set the system or quickly by pressing Set. This removes the exit time Set a Program period. Set 5 seconds insistent beeps Day How to set Chime Zones Example: To set zone 3 and 4 to chime, Press: Chime 3 Day 4 Reset If you omit zones and require Quick Set, you will need to press Set twice. Chime Timeout after 5 seconds if no selection is made Day Chime o/p ARC Set output 0 Deselect all zones (Factory default - no chime) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Appropriate Zone indicator is lit to show chime zone(s) Zone n Chime selected Zone n Chime deselected How to Omit zone(s) on setting system Press number button to select / deselect Zone Chime 1 2 3 4 5 6 7 8 During the exit period after entering User code and selecting a Day program press Set the system or Set a Program and while theOMIT, the exit tone will stop and zones system is setting: that are about to be Omit ZONE(S) TO BE ARMED armed will be displayed. Key in Exit beep the zone number(s) to be omitted which Press the zone(s) n to be omitted will flash to confirm selection. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADE 8SP 401 ACCENTA G3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ADE 8SP 401 ACCENTA G3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag