Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ADE LOGIC 6. We hope that this ADE LOGIC 6 user guide will be useful to you.
Lastmanuals help download the user guide ADE LOGIC 6.
Detailed instructions for use are in the User's Guide.
[. . . ] Intruder alarm system Engineering Information
1 2 3 4 5 6 TA PA
ZONE
Power
Learn Error Day
Accenta/!mini
LGSIX/01 Logic Six panel with two pre learnt Keyfobs
The above intruder system is designed to comply with the installation requirements of BS 4737 1986/87.
4188-753 issue 1_1/03
1 Downloaded from: http://www. guardianalarms. net
Engineering information
Contents
Features - - - - - - - - - - - - - - - - Installation Design - - - - - - - - - - - Fixing the control panel - - - - - - - - Wiring the system - - - - - - - - - - - Tamper network - - - - - - - - - - - - Security zones - - - - - - - - - - - - - PA circuit - - - - - - - - - - - - - - - Extension speaker - - - - - - - - - - - External siren Output (Bell box) - - - - 13V Supply output - - - - - - - - - - - Set - - - - - - - - - - - - - - - - - - Factory set condition - - - - - - - - - - Zone Function - - - - - - - - - - - - - First Power up - - - - - - - - - - - - - Mains Connection - - - - - - - - - - - Testing the system - - - - - - - - - - - System indications - - - - - - - - - - - Programs - - - - - - - - - - - - - - - Walk tests - - - - - - - - - - - - - - - Alarm tests - - - - - - - - - - - - - - How to learn new keyfobs - - - - - - - How to re-learn all keyfobs - - - - - - - How to learn keyfobs if non are recognised Re-arm - - - - - - - - - - - - - - - - Alarm Cycle Counter- - - - - - - - - - Faults - - - - - - - - - - - - - - - - - Specification- - - - - - - - - - - - - - Servicing organisation Details - - - - - Parts - - - - - - - - - - - - - - - - - 2 3 3 4 4 5 6 7 8 9 9 10 10 11 11 12 12 12 13 13 14 15 16 17 17 18 19 20 20
Features
ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ
6 Security zones PA input Tamper input Outputs for External siren (Bell) and Strobe Pre-configured Part set program selectable by DIP switch. Entry Time duration selectable by DIP switch Entry Deviate Alarm Cycle Counter Strobe confirmation on Set Memorises first and subsequent zone intrusions in one alarm period Walk Test facilities by push button control Alarm Test facilities by push button control Battery capacity of up to 2. 1Ah Up to 8 keyfobs can be used with the panel (2 Keyfobs supplied pre learnt) Learn mode to learn new keyfobs Erase mode to disable lost or stolen keyfobs
2
4188-753 issue 1_1/03
Logic Six intruder system
Installation Design
The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding following the procedures and advice contained in this manual. [. . . ] The Learn LED will give a flashing indication and the ZONE LEDs change from flashing to steady On indication to show recognised or learnt keyfob. The Panel is now ready to learn new keyfobs signalled by the next flashing ZONE LED. In the learn mode when an already learnt keyfob is offered to the Panel, an Error indication will be given. The learn mode will timeout after 10 seconds if no action is taken to learn new keyfob Offer a new keyfob slightly touch it on the centre depression of the Panel. A learnt indication is given of the new keyfob when the flashing ZONE LED changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered ZONE LED will start flashing. You now have up to 10 seconds to learn another new keyfob.
Learnt keyfob
keyfob recognised beep x 5 rapid beeps
Learn
1
2
3
Indication given assumes 2 keyfobs were previously learnt by the Panel
Panel
New keyfob
keyfob recognised beep
Learn 1 2 3 4
For keyfobs 7 and 8 the indications are TA and PA LEDs respectively. Repeat to learn the new keyfob.
x 2 beeps
Power Day
Once all the keyfobs are recognised `learnt' by the Panel wait for just over 10 seconds for the Panel to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
14
4188-753 issue 1_1/03
Logic Six intruder system
How to re-learn all keyfobs
Using a recognised learnt keyfob the Panel can re-learn up to 8 keyfobs. You may want to do this after a keyfob is lost or stolen and you want to prevent the use of it to operate the system. Keyfobs must be learnt by each Panel installed in a system By entering the learn mode in this manner you will erase all recognition of previously learnt keyfobs at the Panel, except for the one used to enter the learn mode.
Power Day
Ensure the Panel is in the day mode with the Day LED lit. You must have one learnt keyfob and up to 7 further keyfobs to be learnt. When an unrecognised keyfob is offered to the Panel it will cause the Error LED to be lit and continuous sound to be emitted from the local sounder.
Hold for 20 seconds
Panel
Learnt keyfob
keyfob recognised beep
Learn 1 2 3
x 5 rapid beeps
Hold the recognised `learnt' keyfob slighty touching the centre depression on the Panel and keep it there without movement for 20 seconds. Initially you will hear a keyfob recognition beep and 10 seconds later five rapid beeps from the local sounder. After another 10 seconds you will hear 5 rapid beep tone from the local sounder. The Learn LED will give a flashing indication and the ZONE 1 LED changes from flashing to steady On indication to recognise the learnt keyfob. The Panel is now ready to learn the next keyfob, signalled by the ZONE 2 LED flashing. In the learn mode when an already learnt keyfob is offered to the Panel, an Error indication will be given. The learn mode will timeout after 10 seconds if no actions is taken to learn the next keyfob
Learn 1 2
x 5 rapid beeps
Panel
Next keyfob
Offer the next keyfob slightly touch it on the centre depression of the Panel. A learnt indication is given of the next keyfob when the flashing ZONE LED changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered ZONE indicator will start flashing. You now have up to 10 seconds to start learning another keyfob.
keyfob recognised beep
Learn 1 2 3
x 2 beeps
Power Day
Repeat
to learn the next keyfob.
Once all the keyfobs are recognised `learnt' by the Panel wait for just over 10 seconds for the Panel to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
4188-753 issue 1_1/03
15
Engineering information
How to learn keyfobs if none are recognised
You will only need to learn keyfobs in this manner if no keyfobs are recognised by the Panel. A Panel can learn up to 8 keyfobs following power up of the intruder system. [. . . ] The system will produce the exit beep tone and you should leave the premises by the exit route recommended by your installer. The system will set when the exit beep tone stops. The external strobe will operate for 5 seconds, which provides a confirmation of SET operation. Once any operation is performed using the keyfob withdraw it away from the panel, wait for 3 seconds duration before next use of the keyfob to operate the system.
1 2 3 4 5 6 TA PA
ZONE
Keyfob recognition beep Exit beep Insistent Exit beeps (for final 10 seonds)
Power
4
Logic Six intruder system
How to Unset the system
When you enter your premises you will need to unset (or turn off) the system. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ADE LOGIC 6
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ADE LOGIC 6 will begin.