User manual ADVANSEA T-50

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ADVANSEA T-50. We hope that this ADVANSEA T-50 user guide will be useful to you.

Lastmanuals help download the user guide ADVANSEA T-50.


Mode d'emploi ADVANSEA T-50
Download
Manual abstract: user guide ADVANSEA T-50

Detailed instructions for use are in the User's Guide.

[. . . ] C. 56 / T. 56 / T. 50 USER MANUAL English version Other languages available on the CD-Rom or at: www. advansea. com C. 56 / T. 56 / T. 50 USER MANUAL ­ Ref. 1 Industry Canada Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. FCC Statement Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a normal installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ] 2 Press 3 Press . 3-5-7 No split No split window displays a sonar history at a given frequency (50 or 200 kHz) Low Frequency (50 kHz) The 50 kHz frequency is ideal for detecting the wider area which means low frequency is useful for general detection and judging bottom condition. High Frequency (200 kHz) The 200 kHz frequency is ideal provide a better resolution which means it is ideal for the observation of fish or fish schools. To set a frequency for this display: 1 Once you select No split window, Press . 2 Select the sonar icon then Frequency 3 Select a desired frequency You can also review old sonar records, press and to review the history. To return to current scanning, press . Installation and Operation Manual 29 3-5-8 Split Zoom and Full Screen Zoom Split zoom Split zoom mode expands selected area of the single frequency by VRM(Variable Range Mark). The left side displays zoomed section of current sonar record. The VRM of right side indicates the zoom section area. · Press or to change the zoom range. · Press or to change the depth range. Bottom lock If Bottom lock is on, the zoom depth (the depth of the zoom section) is adjusted automatically so that the bottom is always displayed in the zoom section. · To turn Bottom lock on or off press Full Screen Zoom Full screen zoom displays only the zoom section of split zoom. [Split Zoon] [Bottom Lock] [Full screen zoom] 3-5-9 Split bottom Split bottom display provides a normal picture on the right half and a selectable range over and below the bottom line is expanded onto the left half of the screen. This mode is useful for detecting bottom fishes. · Use the or keys to adjust the zoom range. · Press or to change the range · The VRM moves up and down to calculate the bottom depth automatically. 30 Installation and Operation Manual 3-5-10 Split 50/200 The 50 kHz display appears on the left and the 200 kHz appears on the right. This dual frequency display is very useful for comparing the same scanning with two different frequencies. 3-5-11 Split A-Scope This display shows echoes at each transmission with amplitudes and colors proportional to their intensities; on the right of the screen it is useful for estimating the kind of fish schools and bottom nature. Echo strength color code varies from weakest (blue) to strongest (red). Echoes from fish and the bottom Unwanted noise echoes. The strongest echo, usually from the bottom. Installation and Operation Manual 31 3-6 Highway The Highway window shows a 3D view of the vessel traveling through the water when navigating to a destination point. To go to the Highway window, press and select Highway icon. Boat's plotted course to destination. XTE scale (Cross Track Error). 3-7 Gauges The Gauges window displays all the information you need during navigation such as water, engine, fuel related information, etc. To select the Gauges window, press and select Data icon. Selecting a Gauges layout The Gauges window can show one of seven gauge layouts. [. . . ] During setup to send NMEA data to other instruments, set NMEA out and specify the NMEA data to send. 5-7 NMEA 2000 NMEA 2000 interface standard was introduced for communications network to interconnect marine electronic equipments such as navigation chart plotter, engine, tank level sensor and others on vessels. The standard is regulated by The National Marine Electroincs Association in USA. The AdvanSea chart plotter can be connected to external devices with NMEA2000 and display information such as followings. · Engines have fuel flow sensors, therefore fuel sensors are not required. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADVANSEA T-50

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ADVANSEA T-50 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag