User manual AEG-ELECTROLUX 7509D-M-A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX 7509D-M-A. We hope that this AEG-ELECTROLUX 7509D-M-A user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX 7509D-M-A.


Mode d'emploi AEG-ELECTROLUX 7509D-M-A
Download
Manual abstract: user guide AEG-ELECTROLUX 7509D-M-A

Detailed instructions for use are in the User's Guide.

[. . . ] If the cooker hood is connected to chimneys no longer in use, it is advisable to seek the consent to the competent chimney-sweeper. if the cooker hood is installed in the evacuation mode , the requirements of the concerned authorities have to be observed. An adequate air inlet having the same size as the air outlet is to be ensured. If the room where the cooker hood is to be used contains other non-electric appliances (such as gas or coke appliances), their use is subject to some restrictions. [. . . ] Fit the charcoal filters ensuring that they click into position correctly. The cooker hood can be installed in two different ways: RECIRCULATION FITTING: using two charcoal filters to catch the odours and to recirculate the air back into the kitchen. The ducting should be long enough to project through the hole in the top of the cabinet. If you wish to install the appliance in evacuation mode, the charcoal filters are not required. Fit the venting grille over the ducting and screw the grille to the top using the screws provided. Your appliance must be connected to fixed wiring via the use of a double pole switched fused spur outlet with or without pilot lamp. We strongly recommend the appliance is connected by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations. Attention should be taken when installing the ducting to choose the shortest possible run with the minimum number of bends. The use of bends may cause a loss of air capacity and should be avoided where possible. NOTE: The terminology "DOUBLE POLE" means that both the live and neutral supplies are switched and disconnected at the same time. The terminations laballed SUPPLY are for connection for the internal house wiring and the terminations labelled LOAD are for the appliance. IMPORTANT - The wires of the mains load supplied with this appliance are coloured in accordance with the following code: Blue - Neutral Brown - Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the terminals in your plug, poceed as follows: The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. Never leave the burners of the hob uncovered while the hood is in use: an excessive heat could damage the appliance. open-fire cooktops , such as oil- , gas- and coalfired cooktops , must be avoided. Never leave frying pans unattended during use as overheated fat and oils may catch fire. Before carrying out any kind of cleaning or maintenance, even the replacement of the fluorescent strip light, disconnect the appliance unplugging the cooker hood or acting on the mains supply. The symbols and numbers have the following meaning: Motor M = Motor switch 0 1 2 3 = = = = The motor is off Low speed Medium speed Top speed Lighting L = Lighting switch 0 = Lighting is off 1 = Lighting is on Controls The movement of the visor can be used to switch the appliance on and off. Before carrying out any kind of maintenance, disconnect the hood form the mains supply or unplug the appliance. Metal filters The metal filters retain grease particles and are used both in evacuation and recirculation mode. [. . . ] do not use abrasive cleaners , brushes or scouring agents. Control panel should be cleaned only with a damp cloth and mild detergent. There could be a possible fire hazard if the grease filters are not cleaned or replaced when necessary and according to these instructions. In case of any enquiries or faults, please call our After Sales Service (see list of After Sales Centres). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX 7509D-M-A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX 7509D-M-A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag