User manual AEG-ELECTROLUX EGT6242

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX EGT6242. We hope that this AEG-ELECTROLUX EGT6242 user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX EGT6242.


Mode d'emploi AEG-ELECTROLUX EGT6242
Download
Manual abstract: user guide AEG-ELECTROLUX EGT6242

Detailed instructions for use are in the User's Guide.

[. . . ] EGT6242 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN HOB USER MANUAL 2 www. electrolux. com CONTENTS 1. 14 WE'RE THINKING OF YOU Thank you for purchasing an Electrolux appliance. [. . . ] Manufacturer decline any responsibility in case misuse of the flame Always light the burner before you put cookware. To light the burner: Turn the control knob counterclockwise to the maximum position ( ) and push it down. Keep the control knob pushed for approximately 5 seconds; this will let thermocouple to warm up. If not, the gas supply will be interrupted. Adjust the flame after it is regular. 1. C) Ignition candle D) Thermocouple WARNING!Do not keep the control knob pushed for more than 15 seconds. If the burner does not light after 15 seconds, release the control knob, turn it into off position and try to light the burner again after minimum 1 minute. In the absence of electricity you can ignite the burner without electrical device; in this case approach the burner with a flame, push the relevant knob down and turn it counter-clockwise to maximum gas release position. If the burner accidentally goes out, turn the control knob to the off position and try to light the burner again after minimum 1 minute. The spark generator can start automatically when you switch on the mains, after installation or a power cut. It is normal. If after some tries the burner does not light, check if the crown and its cap are in correct positions. A B C 3. 2 Turning the burner off To put the flame out, turn the knob to the symbol . Always turn the flame down or switch it off before you remove the pans from the burner. D A) Burner cap B) Burner crown 4. Refer to "Safety information" chapter. Use cookware with diameters applicable to the size of burners. Burner Rapid Front Semirapid 4. 1 Energy savings · If possible, always put the lids on the pans. · When the liquid starts to boil, turn down the flame to barely simmer the liquid. Diameters of cookware 180 - 260 mm 120 - 220 mm ENGLISH 7 Burner Rear Semirapid Auxiliary Diameters of cookware 120 - 220 mm 80 - 180 mm Do not place unstable or deformed pots on the rings to prevent from spill and injury. Liquids spilt during cooking can cause the glass to break WARNING!Do not use cast iron pans, potstones, grill or toaster plates on gas burners. Do not put the same pan on two burners. Information on acrylamides Important!According to the newest scientific knowledge, if you brown food (specially the one which contains starch), acrylamides can pose a health risk. Thus, we recommend that you cook at the lowest temperatures and do not brown food too much. WARNING!Make sure pot handles do not protrude over the front edge of the cooktop and that pots are centrally positioned on the rings in order to achieve maximum stability and to obtain lower gas consumption. 5. Refer to "Safety information" chapter. [. . . ] The appliance must be connected to a 230 V 50 Hz AC electrical supply. Before activating the appliance, make sure the electrical supply voltage is the same as that indicated on the rating plate. A) The by-pass screw · If you change from natural gas G20 20 mbar to liquid gas, fully tighten the adjustment screw in. · If you change from liquid gas to natural gas G20 20 mbar, undo the by-pass screw approximately 1/4 of a turn. Make sure the flame does not go out when you quickly turn the knob from the maximum position to the minimum position. 12 www. electrolux. com The rating plate is located on the bottom of the appliance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX EGT6242

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX EGT6242 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag