User manual AEG-ELECTROLUX ETN1061V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX ETN1061V. We hope that this AEG-ELECTROLUX ETN1061V user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX ETN1061V.


Mode d'emploi AEG-ELECTROLUX ETN1061V
Download
Manual abstract: user guide AEG-ELECTROLUX ETN1061V

Detailed instructions for use are in the User's Guide.

[. . . ] There is risk of fire or electric shock. Do not touch (operation) the product with wet hands. There is risk of fire or electric shock. Do not place a heater or other appliance near the power cable. [. . . ] Pipe temperature sensor. Room temperature control Maintain the room temperature in accordance with the setting temperature. Anti-freezing control in cooling Prevent the water being frozen on evaporator by sensing the evaporator pipe temperature in cooling mode Work voltage (160v-253v) High efficiency (30%) Tele Remote control (Optional) Time Delay Safety control Restarting is for approx. 3 minutes. . Indoor fan speed control Turbo wind, high, med, low, breeze. Self-diag. function Anti-cold function Two-direction air vane The unit will decide the louver direction according to operation mode. Prevent the cold wind at the beginning of unit start Sleep mode auto control The fan is turn to low speed (cooling/heating). The unit will be turn off at the seventh hour. Independent dehumidification The function is usually used in rainy days in springtime or damp areas. Auto defrosting Auto-restart function When the power supply is interrupted and then restore, the air conditioners automatically restore the previous function setting. Air flow Direction control The louver can be set at the desired position or swing up and down automatically Auto mode The mode can be change by the room temperature. Flexible wiring connection DSP High-speed Chip Temp. Compensation Driving heating at -15 3 Service manual Outdoor unit Power relay control The unit has 3 minutes delay between continuously ON/OFF operations. Low noise air flow system Bird tail propeller fan makes the outdoor unit run more quietly. Hydrophilic aluminum fin The hydrophilic fin can improve the heating efficiency at operation mode. 4 way valve control It is only operated in the heating operation mode except defrosting operation. Anti-rust cabinet Made from electrolytic zinc steel sheet and anti-rust coated components. Valve protection cover It protects the valves and prevents water from dripping. Discharge pipe temperature protect 4 Service manual 3 Dimension 3. 1 Indoor unit (Inverter Eco) model 7K/9K 12K W 750 815 H 250 280 A 188 195 3. 2 Outdoor unit (Inverter Eco) Dimension Model 7K/9K/12K W 780 H 540 D 250 L1 530 L2 315 L3 590 5 Service manual 4 Specification Model MSG-07HRIN2 220-240V~ 50Hz Capacity Input BTU/H W A 7000(2700~9000) 780(305~990) 4. 8(1. 35~6. 2) 9. 0, 2. 62 9000(2700~11000) 940(280~1140) 4. 4(1. 35~6. 7) 2. 81 1. 0 W Model Type Brand 2300 BG130X1C-20FZ Rotary Inverter MSG-09HRIN2 220-240V~ 50Hz 9000(2730~10600) 990(305~1180) 4. 5(1. 2~6. 6) 9. 0, 2. 62 12000(2730~14000) 1240(283~1450) 5. 5(1. 45~9. 3) 2. 82 1. 0 2300 BG130X1C-20FZ Rotary Inverter MSG-12HRIN2 220-240V~ 50Hz 12000(3070~13300) 1340(334~1494) 5. 8(1. 60~7. 60) 9. 0, 2. 61 15000(3070~17060) 1560(320~1773) 6. 8(1. 6~10. 6) 2. 82 1. 2 2600 BG130X1C-20FZ Rotary Inverter Power source Cooling Running current EER Capacity Input Heating Running current COP Moisture removal Max. input consumption L/h A W/W BTU/W. H, W/W BTU/H W TOSHIBA ml 370 POE uF g \ 850 W RPG13H Welling uF 1. 2uF/450VAC 3 1050/950/750 500/410/320 35/32/26 YDK25-6-3 2. 5uF/450VAC Welling 51 (W*H*D) (W*H*D) kg 750*250*188 830*336*280 8/10 780*540*250 910*575*335 37/40 6. 35 9. 53 10 5 17~30 -15~45 m2 14-18 TOSHIBA 370 POE \ 850 RPG13H Welling 1. 2uF/450VAC 3 1100/1000/800 520/430/330 36/32/26 YDK25-6-3 2. 5uF/450VAC Welling 51 750*250*188 830*336*280 8/10 780*540*250 910*575*335 37/40 6. 35 9. 53 10 5 17~30 -15~45 18-24 TOSHIBA 370 POE \ 1200 RPG13C Welling 1. 5uF/450VAC 3 1060/900/800 560/460/380 36/32/26 YDK25-6-3 2. 5uF/450VAC Welling 53 815*280*195 915*360*275 9/12 780*540*250 910*575*335 40/43 6. 35 12. 7 10 5 17~30 -15~45 20-30 Compressor Refrigerant oil Refrigerant oil type Capacitor Refrigerant R407C Input Brand Indoor fan motor Capacitor Speed level Hi/Mid/Lo speed ( rpm) Air flow(indoor) Noise level (indoor) Hi/Mid/Lo Hi/Mid/Lo Input Outdoor fan motor Capacitor Brand Noise lever (outdoor) dB(A) dimension Indoor unit Packing m3/h dB(A) W uF Net/Gross weight dimension Outdoor unit Packing (W*H*D) (W*H*D) kg mm mm Net/Gross weight Liquid side Gas side Refrigerant piping Max. difference in level Operation temp Ambient temp Application area 6 Service manual 5 Refrigerant cycle diagram 7 Service manual 6 6. 1 Operation limits Cooling operation Outdoor unit air temp. DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage. 6. 2 Heating operation Indoor air temp. DB Note: The chart is the result from the continuous operation under constant air temperature conditions. Confirm that both the 2-way and 3-way valves are set to the open position. Connect the charge set to the 3-way valve's service port. Leave the valve on the charge set closed. Connect the charge hose with the push pin to the service port. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge indicates 0. 05 to 0. 1 Mpa. If there is no air in the refrigeration cycle [the pressure when the air conditioner is not running is higher than 0. 1Mpa, discharge the refrigerant until the gauge indicates 0. 05 to 0. 1 Mpa. If this is the case, it will not be necessary to apply a evacuation. Discharge the refrigeration gradually; if it is discharged too suddenly, the refrigeration oil sill be discharged. 15 Service manual 8. 8 Evacuation Procedure: 1. Connect the vacuum pump to the charge set's centre hose. Confirm that the gauge needle has moved toward -0. 1 Mpa (-76 cmHg) [vacuum of 4 mmHg or less]. Close the valve (Low side) on the charge set, turn off the vacuum pump, and confirm that the gauge needle does not move (approximately 5 minutes after turning off the vacuum pump). [. . . ] Timer on: first turn off the A/C, the A/C will be automatically on at the set time. Timer off: first turn on the A/C, the A/C will be automatically off at the set time Timer on/off function( on time is earlier than off time): first turn off the A/C, it will be automatically on at set time, and later be off at the set time, then unit turns on at set time. 9. 11. 5 Timer off/on function( off time is earlier than on time): first turn on the A/C, it will be automatically off at set time, and later be on at the set time, then unit turns off at set time. 9. 12 Auto restart function In case of a sudden power failure, this function automatically sets the unit to previous settings before the power failure when power returns. 22 Service manual 10 10. 1 Defrosting Troubleshooting Indoor Unit Error Display Timer Auto Operation LED status Module protection Compressor top protection against temperature Open or short circuit of outdoor temperature sensor Over load or too low voltage protection Open or short circuit of indoor temperature sensor Fan speed out of control Zero-crossing examination error EEPROM data error Indoor/outdoor communication protection Low temperature protection of outdoor ambient X O X X O O X O O X X O O O O X X X X O X X O O O O bright 10. 2 extinguished flash Outdoor Unit Error Display There is a LED(red) on outdoor main control board. The LED flashes at a frequency of 0. 5Hz if the unit is standby. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX ETN1061V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX ETN1061V will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag