User manual AETHRA AC203X DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AETHRA AC203X. We hope that this AETHRA AC203X user guide will be useful to you.

Lastmanuals help download the user guide AETHRA AC203X.


Mode d'emploi AETHRA AC203X
Download
Manual abstract: user guide AETHRA AC203XDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] [. . . ] AC203x cross connects and concentrates up to 128 Virtual Circuit Connections (VCC) over a single or a dual high speed link to the backbone ATM network, reaching up to 4608kbps (4-wire mode). Deploying an inexpensive and highly scalable network infrastructure using AC203x replaces obsolete DCE, HDSL transceivers, TDM cross-connects, and other leased line network equipment. AC203x Technical Specifications LED Indicators · PWR · RDY (Fail) · E1: LOS, LFA, ACT, AIS (alarms) · ShDSL (Link, Sync) · VX (Act) Physical Interfaces · Balanced E1 G. 703/G. 704 interface with RJ-45 or external adapter-BALUN for AC2033 and AC2033T models · Balanced and unbalanced E1 G. 703/G. 704 interface with RJ-45 or external adapter-BALUN for AC2036/7 models · VX - V. 35 (standard V. 35 connector) for AC2036 and AC2037 models - V. 35, V. 36/RS. 449, X. 21/V. 11 (ITU-T V. 35, ITU-T V. 36, ITU-T V. 11, TIA/EIA-530, TIA/EIA RS-449, proprietary 25pole female connector1) for AC2033 and AC2033T models · Local configuration auxiliary interface one RS-232 interface(DB9 cable) ShDSL Network Interfaces · ShDSL interface: up to 2312 kbps for 2-wire model, up to 4608 kbps for 4-wire models · ETSI TS 101 524 · ITU G. 991. 2 · Line rate - up from 200 kbps to 2312 kbps for AC2036 - up from 200 kbps to 4608 kbps for AC2033/T Operating Modes · Circuit Emulation Service forAC2033/T models · Frame Relay to ATM · Cell bridging · Time-Division Multiplexing for AC2033/t models · Simultaneous Circuit Emulation and Frame Relay to ATM interworking services on E1 and serial interface Frame Relay · Support for up to 128 PVCs · FRF. 1 UNI · Up to 10 classes for traffic policy Interworking Functions · Configurable per VCs · Network Interworking FRF. 5 · Service Interworking FRF. 8. 1 · Transparent mode · Protocol Translation (RFC2427, RFC2684) Circuit Emulation Service · Structured and unstructured data mode · Playout buffer size · Partial cell filling · CES ATM forum atm-vtoa-0078. 000 Mixed Mode Features · Up to 128 ATM VCs · Up to 128 NIW or SIW channels · CBR and UBR configurable for VC · 8 CES channel Timing · Local · Adaptive · Network Local Management Interface (LMI) · Selectable Q. 933 Annex A or ANSI T1. 617 Annex D) · Standard or bi-directional procedures · Management local or remotely configured and operated using a designed ATM VCC Configuration and Management · Password Protected Access: - 2 login levels - Local authentication · Local Management - Console port - Extensive CLI - Windows® based wizard for configuration and firmware download · Remote Management (configuring a dedicated VC maintenance and using a remote host) - CLI (internal Telnet Server) - HTTP (embedded WEB Server) - SNMP Agent (v1, v2c) - Syslog - Ping MIB · Firmware upgrades: Local and Remote (TFTP client embedded) Environment · Operating Temperature: -5° ÷ 45°C (23° ÷ 113°F) · Non-Operating Temperature: -40° ÷ 70°C (-40° ÷ 158°F) · Operating Humidity: 10 ÷ 93% (non-condensing) Compliance & Approvals · Storage: ETSI EN 300 019-2-1 T 1. 3 · Transportation: ETS 300 019-2-2, T 2. 3 · Operating Conditions: ETS 300 019-2-3, T 3. 2 · EMC: EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3 · Protection: ITU-T K. 21 · Safety: EN 60950-1 Power · External power supply · AC input voltage: 100 to 240 Vac · AC input frequency: 50 to 60 Hz · AC input current: 0. 2 to 0. 38 A Dimensions · Length 180 mm · Width 145 mm · Height 40 mm Notes 1 Dedicated cable available ShDSL port E1 lfc Serial lfc Operating Modes Cell Bridging FR to ATM Interworking AC2036 single balanced and unbalanced standard V. 35 connector AC2037 dual balanced and unbalanced standard V. 35 connector Cell Bridging FR to ATM Interworking AC2033 dual balanced proprietary 25pole female connector V. 35, V36/RS. 449, X. 21/V. 11 Cell Bridging FR to ATM Interworking CES TDM A TLC Srl Legal Office via Giovanni Battista Martini, 2 00100 Roma (Italy) Operating Office via Matteo Ricci, 10 60126 Ancona (Italy) Telephone +39. 071. 250651 Email:info@aethra. com www. aethra. com All information provided by A TLC in this datasheet is believed to be accurate. A TLC Srl reserves the right to discontinue and change specifications and prices at any time without prior notice. Copyright © 2010 A TLC Srl - all rights reserved. [. . . ] [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AETHRA AC203X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AETHRA AC203X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag