User manual AETHRA D2500 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AETHRA D2500. We hope that this AETHRA D2500 user guide will be useful to you.

Lastmanuals help download the user guide AETHRA D2500.


Mode d'emploi AETHRA D2500
Download
Manual abstract: user guide AETHRA D2500DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] D2500 Telecom Analyzer ISDN & Telecom standards On board support for multiple protocols WAN & DATACOM Leased line & Datacom Pre-Qualification Testing Flexible Operation Control all Functions locally or via Remote Control The D2500 Telecom Analyzer is the culmination of thirty years of experience that Aethra has in the development and production of test instruments. [. . . ] Graphic Interfaces The new, improved Graphical User Interface uses smart windows drop-down menus. This makes navigating around the configuration procedures extremely easy and minimizes time required to achieve proficiency with the tester. Smart StatusTM This feature is always available - even while a test is in progress, thus allowing continuous monitoring of clock frequency, alarms, errors, PCM time-slot status, channel configurations and test parameters, as well as the unit's own device status. D2500 Technical Specifications Telecom Interfaces · Basic Rate Access - S/T : ITU-T Rec. I. 430, ETS 300 012 - U : 2B1Q and 4B3T, TS 102 080 · Primary Rate Access Manual sending · Types : Bit, LFA, LOS, AIS, NMFAS, Sa, RAI (A bit), E bit, CRC, CV, control leads Generate Traffic · Number of cycles : Up to 65535 · Number of parallel calls : Up to 30 (PRI) · Delay between calls : User selectable X. 25/X. 31 · Modes : SVC, PVC · Logical Types : DTE, DCE · Tests : Traffic generator, Echo port IP · Modes : IP routed, IP over PPP (Client and Server) · IP address supported : Static, Dynamic · Authentication protocol : PAP, CHAP (MD5) · Protocols : IPv4, UDP, DNS, DHCP, ICMP, TFTP, HTTP, FTP Frame Relay (FR2K) · Frame Relay Forum : FRF. 1. 1, FRF. 3. 1, FRF. 12. 1, FRF. 14 · Type of traffic : IP, IP over PPP · LMI : ITU-T Q. 933, ANSI T1. 617, original LMI CISCO · Logical Types : UNI, CPE, NNI · QoS statistics : FECN, BECN, DE, NLPID, DLCI, FRF. 12 U-BUS loop qualification · U-Bus voltage measurement · Loop resistance measurement () · Programmable simulation "NT-load" over U-Bus · Activation/Deactivation time measurement (msec. ) History and predefined tests features Saving and recalling of 10 different setup and results for each kind of test Connectors · Primary Access interface : RJ45 120, BNC 75 · V. 11/X. 21 : DB-15 · S/T Basic Access interface : RJ45 (ISO 8877) · U Basic Access interface : RJ45 (ISO 8877) · RS232 : DB-9 (V. 28 CCITT ISO4902) · Handset : 4 wires RJ9. Balanced, 600 · Power in : External AC/DC adapter · Power out : Mini-DIN 4 wires connector Environmental characteristics · Dimension - Weight, with battery : 1 kg - Dimensions with holster (mm) : 130(w)x260(l)x65(d) · Power - Battery Type : Rechargeable, Ni-MH - Battery life : 3 hours @ 25°C, LCD back-lit off - External AC/DC adapter : 115/230Vac ±10%@50/60Hz Temperature · Storage/Transport : - 40°C to +70°C · Operating, nominal : - 5°C to +45°C · Operating, limits : -10°C to +55°C · Humidity, non-condensing - 93% RH @ 40°C - 70% RH @ 55°C · User's Safety Aspects : EN 61010-1, EN 60950, EN 41003 · EMC Aspects : EN 55022, EN55024, EN 61000-3-2 / -3-3 · CE Marking : Class B (residential devices) - Interface CCITT G. 703 (2Mbps) / G. 704 - E1 : ITU-T Rec. I. 431, ETS 300 011 - 2Mbit : PCM30/CRC, PCM31/CRC, Unframed · WAN/Datacom (option) - Sync : X. 21/V. 11, V. 24, V. 35, V. 36 (RS449), G. 703 codir - Bit Rates : 50bps - 2048Kbps (Nx64) - Async V. 24 (RS232) - Bit Rates : 50bps - 230400bps - V. 11/X. 21 interface : Integrated on board (VX21-2500 option) - Clock frequency Measurement (±1Hz) and shift management (±100ppm) Protocols Supported · Simulation mode : EDSS-1, Q. SIG, 1TR6, TN1R6®, VN4, X. 25, X. 31, DASS-2, DPNSS, CorNet®-N, -NX, -NQ, -T, PPP, IP, UDP, DHCP, ICPM, TFTP, HTTP, FTP, Frame Relay, · Monitor mode : EDSS-1, Q. SIG, 1TR6, TN1R6®, VN4, X. 25, X. 31, DASS-2, DPNSS, CorNet®-N, -NX, -NQ, -T, · Other protocols available : V. 5. 1, V. 5. 2, NI1, DMS100, 5ESS Operating Modes Available · Basic Rate Access : BRI TE-S, BRI MON-S, BRI NT-S, BRI NT-U, BRI MON-U (D2022 option), BRI LT-U (LTU2K option), BRI S/T-Bus wiring test, (WT2000 option) · Primary Rate Access : PRI TE-E1, PRI MON-E1, PRI MON-E1 PMP, PRI NT-E1, · POTS/Analog TE (AB2000N option), MON (AB2000N option) · V/X : DTE, DCE (VX2000 and VX21-2500 option when required) · Pattern generation : Single, n x 64Kbit timeslot Smart StatusTM · G. 826/M. 2100 (only PRI) : ES, SES, BBER, UAS · ISDN line : Layers 1, 2, 3 and B ch status · V/X interface : Control leads, test running, loop, clock frequency, clock phasing · 2Mbit : FAS, NFAS, MFAS, NMFAS, alarms, errors, sync, CAS channel status, · Frame Relay (FR2K) : DLCI, LMI, and quality test Background Monitor · Modes : High impedance and during simulation · Protocol analysis on-board · Programmable filters : Independent filters' capturing and displaying · Statistics information · Analysis of the results : stored on PC PC108 for WindowsTM Automatic Access Test · Fully automated Access test · Supplementary services automatic test · Programmable test sequence Bit Error Rate Test · G. 821 statistics : ES, SES, US, DM, PASS/FAIL, S-LOSS · Pseudo-Random bit sequences User : definable 211-1, 215-1, 223-1, All 0's, All 1's, 10101010, 16 bit octet, HDLC frame · Error Injection : Manual, Automatic, Single Miscellaneous · LCD display : 240x200 Graphic display wide bright an back-lit · Internal microphone & loudspeaker · Upgradable firmware · MultiMediaCardTM memory extension MMC2000 Option Options · INET2500 : HTTP, FTP Internet download · VX21-2500 : X. 21 / V. 11 interface · WT2000 : S0/T0 wiring test · AB2000N : Analog (POTS) line adapter · LT-U2K : BRI LT-U simulation · D2022-Q : BRI U (2B1Q) interface monitor · D2022-T : BRI U (4B3T) interface monitor · MMC2000 : MMC Memory extention · VX2000 : DTE/DCE Datacom tester · FR2K : Frame Relay test suite · PC108XP EXPERT license : More performing version for protocol analysis and remote management · KCX21-DXE2500 : X21/VII DTE/DCE CABLE KIT · KCX2K-DTE - Cable Kit for VX2000 - DTE simulation mode · KCX2K-DCE - Cable Kit for VX2000 - DCE simulation mode A TLC Srl Legal Office via Giovanni Battista Martini, 2 00100 Roma (Italy) Operating Office via Matteo Ricci, 10 60126 Ancona (Italy) Telephone +39. 071. 250651 Email:info@aethra. com www. aethra. com All information provided by A TLC in this datasheet is believed to be accurate. [. . . ] Copyright © 2010 A TLC Srl - all rights reserved. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AETHRA D2500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AETHRA D2500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag