User manual AIRLIVE WL-5470AP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AIRLIVE WL-5470AP. We hope that this AIRLIVE WL-5470AP user guide will be useful to you.

Lastmanuals help download the user guide AIRLIVE WL-5470AP.


Mode d'emploi AIRLIVE WL-5470AP
Download

You may also download the following manuals related to this product:

   AIRLIVE WL-5470AP DATASHEET (384 ko)
   AIRLIVE WL-5470AP QUICK SETUP GUIDE (3093 ko)

Manual abstract: user guide AIRLIVE WL-5470AP

Detailed instructions for use are in the User's Guide.

[. . . ] WL-5470AP 802. 11g Hi Power Multifunction AP/Router User's Manual AirLive WL_5470AP User's Manual 1 Declaration of Conformity We, Manufacturer/Importer OvisLink Corp. 5F. , NO. 6, Lane 130, Min-Chuan Rd. , Hsin-Tien City, Taipei County, Taiwan Declare that the product 802. 11b/g Multi-function Wireless Access Point AirLive WL-5470AP is in conformity with In accordance with 89/336 EEC-EMC Directive and 1999/5 EC-R & TTE Directive Clause EN Description Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband transmission equipment operating in the 2. 4GHz ISM band And using spread spectrum modulation techniques; Part 1technical Characteristics and test conditions Part2Harmonized EN covering Essential requirements under article 3. 2 of the R&TTE Directive Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic compatibility(EMC) standard for radio equipment and Services; Part 17Specific conditions for wideband data and HIPERLAN equipment Generic standard to demonstrate the compliance of low power Electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic field (10MHz ­ 300GHz) -General public Safety for information technology equipment including electrical business equipment 300 328 V1. 7. 1 (2006-10) EN 301 489-1 V1. 5. 1 (2004-11) EN 301 489-17 V1. 2. 1 (2002-08) EN 50371:2002 EN 60950-1:2001/ A11:2004 marking CE Manufacturer/Importer Signature Name Position/ Title : Albert Yeh Vice President (Stamp) Date 2007/6/28 AirLive WL-5470AP CE Declaration Statement Declaration OvisLink Corp. tímto prohlasuje, ze tento AirLive WL-5470AP je ve shod se základními pozadavky a dalsími píslusnými ustanoveními smrnice 1999/5/ES. erklærer herved, Dansk [Danish] at følgende udstyr AirLive WL-5470AP overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. [. . . ] If the "Hidden Node" problem is an issue, please specify the packet size. The RTS mechanism will be activated if the data size exceeds the value you set. . Warning: Enabling RTS Threshold will cause redundant network overhead that could negatively affect the throughput performance instead of providing a remedy. This value should remain at its default setting of 2347. Should you encounter inconsistent data flow, only minor modifications of this value are recommended. Beacon Interval Beacon Interval is the amount of time between beacon transmissions. Before a station enters power save mode, the station needs the beacon interval to know when to wake up to receive the beacon (and learn whether there are buffered frames at the access point). Data Rate By default, the unit adaptively selects the highest possible rate for transmission. Select the basic rates to be used among the following options: Auto, 1, 2, 5. 5, 11or 54 Mbps. For most networks the default setting is Auto which is the best choice. When Auto is enabled the transmission rate will select the optimal rate. If obstacles or interference are present, the system will AirLive WL_5470AP User's Manual 21 automatically fall back to a lower rate. Preamble Type A preamble is a signal used in wireless environment to synchronize the transmitting timing including Synchronization and Start frame delimiter. In a "noisy" network environment, the Preamble Type should be set to Long Preamble. The Short Preamble is intended for applications where minimum overhead and maximum performance is desired. If in a "noisy" network environment, the performance will be decreased. Broadcast SSID Select enabled to allow all the wireless stations to detect the SSID of this Access Point. IAPP IAPP (Inter Access Point Protocol) is designed for the enforcement of unique association throughout a ESS (Extended Service Set) and a secure exchange of station's security context between current access point (AP) and new AP during handoff period. 802. 11g Protection The 802. 11g standard includes a protection mechanism to ensure mixed 802. 11b and 802. 11g operation. If there is no such kind of mechanism exists, the two kinds of standards may mutually interfere and decrease network's performance. TX Power Level For countries that impose limit on WLAN output power, it might be necessary to reduce TX (transmit) power. There are 7 TX Power Levels to choose from -- select a level to make sure that the output power measured at the antenna end will not exceed the legal limit in your country. Enable Watch dog Watch Interval Watch Host ACK Timeout Check and enable this watch dog function Setup the interval time for watch dog function between 1 to 60 mins Enter the watch dog host ip address . When a packet is sent out from one wireless station to the other, it will waits for an Acknowledgement frame from the remote station. [. . . ] To enable 802. 1d Spanning Tree will prevent the network from infinite loops. Infinite loop will happen in the network when WDS is enabled and there are multiple active paths between stations. AirLive WL_5470AP User's Manual 41 Clone MAC Address You can specify the MAC address of your Access Point to replace the factory setting. 4. 12 Reboot Click the Reboot button to restart device. AirLive WL_5470AP User's Manual 42 Chapter V: Other Upgrade Firmware 1. Download the latest firmware from your distributor and save the file on the hard drive. Start the browser, open the configuration page, click on Other, and click Upgrade Firmware to enter the Upgrade Firmware window. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AIRLIVE WL-5470AP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AIRLIVE WL-5470AP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag