User manual AIRWELL AWSI-HDD012-N11

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AIRWELL AWSI-HDD012-N11. We hope that this AIRWELL AWSI-HDD012-N11 user guide will be useful to you.

Lastmanuals help download the user guide AIRWELL AWSI-HDD012-N11.


Mode d'emploi AIRWELL AWSI-HDD012-N11
Download
Manual abstract: user guide AIRWELL AWSI-HDD012-N11

Detailed instructions for use are in the User's Guide.

[. . . ] Bottom side of bracket should be 45 mm below top of unit position, when installed on the wall. Check that the anti vibration packing (2) on the mounting bracket and on the backside of the unit (3) is undamaged. Lift the unit into position and make sure that there is no direct contact between unit and building construction. 1) The unit should preferably be installed in a separate room (e. [. . . ] Inlet diffuser should be mounted in the ceiling. Make sure that the air stream from inlet diffusers has a free passage. Air stream from inlet diffuser mounted on the wall (where the ceiling is horisontal), must have throw length, so that the air is supplied to the room alongside the ceiling. Air supply through extract louvers will ensure an air stream with throw length, and extract louvers can therefore be used as inlet diffusers when mounted in the wall close to the ceiling. Use frames to ease the removing of diffusers for cleaning. Setting of air volume For basic setting of inlet diffusers, open core of the diffuser 5-7 turns from closed position. For basic setting of extract louvers, open core of the diffuser 10 turns from closed position. For adjustment of air volumes to each separate room, setting on diffusers/louvers are to be made in accordance with calculations made during designing of the ventilation system or during commissioning of the system (special measuring equipment required). 3 Air circulation between rooms (Fig 7) To obtain a satisfactory air circulation, a small gap should exist around the doors between rooms with inlet diffusers (living rooms and bedrooms) and rooms with extract points (bathroom, WC, kitchen, laundry rooms etc. Install doors with slot in 2 the frame, doors without door sill or slots/vents in doors/wall (min. There will normally be no under pressure in the building, and therefore no risk for back draught from fireplace or chimney. Supply air duct directly to the fireplace would be the optimal solution, but 2 pcs. 16x16 cm closing vents in outer wall is a good alternative. 16x16 cm vents could be installed for air supply to tumble dryer and kitchen ventilator (one for each). These should preferable be installed in the same room. An open window will also give the required air supply to fireplace, kitchen ventilator and tumble dryer. 10) The unit (2) The VR 400 DCV/B & VR 700 DCV units are supplied with apx. 1 m cable and plug for 10A, 230V, single phase earthed connection. The cookerhood (1) VR 400 DCV/B is designed for connection to cookerhood, designed for this use. 1 m cable and plug for 10A, 230V, single phase earthed connection and cable for potential free signal to unit. When opening the timer operated damper in the cookerhood, the fans will automatically go to maximum capacity. Install a 2 lead wire for potential free signal from cookerhood to the unit. [. . . ] ADDITIONAL EQUIPMENT For more information about diffusers/louvers, roof unit, wall grill etc. The airvolume input has to be done in l/s. If start-up of the system is delayed, the duct system must be protected (by means of bungs) so that air circulation is prevented. This is to avoid condensation and damage in the ventilation unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AIRWELL AWSI-HDD012-N11

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AIRWELL AWSI-HDD012-N11 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag