User manual AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE. We hope that this AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE user guide will be useful to you.

Lastmanuals help download the user guide AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE.


Mode d'emploi AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE
Download
Manual abstract: user guide AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE

Detailed instructions for use are in the User's Guide.

[. . . ] In addition to the processor, up to 2 contact closure boards (HWI-CCO8 or HWI-CCI-8) and/or wire landing boards (HWIWLB) may be mounted in the 24 in. Contact closure outputs provide low-voltage control of motors and shades. Contact closure inputs allow interfacing to photocells, security systems, and other home systems. [. . . ] Recess Mount - Use screws sufficient for 30 lbs. (14 kg) through the sides of the enclosure (see Mounting Diagram, page 1). Mount enclosure flush to or not more than 1/8 in. Enclosure cover dimensions are 24-1/2 in. Danger - Locate and lock supply breaker in the OFF position before connecting power input. Wiring Diagram Low-voltage wiring entry Additional Low-voltage wiring entry No high-voltage in shaded area (Class 2 only) 2. Remove high voltage cover and run power wiring into the enclosure. Locations to run power wiring into the enclosure are as shown in Wiring Diagram. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. Strip insulation 1/2 in. (10 mm) for 10 AWG (6 mm2), 12 AWG (4 mm2) or 14 AWG (2. 5 mm2). (16 mm) for 16 AWG (1. 5 mm2) or 18 AWG (1. 0 mm2). Use to join one or two 12 or 14 AWG supply wires with one 10, 12, 14, 16 or 18 AWG control wire. Power wiring entry (remove high-voltage cover to access) High-voltage section Connect Hot/Live feed to the black wire, Neutral feed to the white wire, and Earth Ground to the green wire. If the processor and the accessory boards are not to be installed at this time, install the enclosure cover. (Instructions for installing the processor and accessory boards are supplied with the processor). Ensure product identification label is at the bottom of the cover. (2. 3 Nm). LIMITED WARRANTY Technical and Sales Assistance If you need assistance, call the toll-free Lutron Technical Support Center. Please provide exact model number when calling. (800) 523-9466 (U. S. A. , Canada and the Caribbean) Other countries call: Tel: (610) 282-3800 Fax: (610) 282-3090 Visit our Web site at www. lutron. com Lutron Electronics Co. , Inc. [. . . ] This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX 4-SERIES LOW-VOLTAGE ROUGH-IN ENCLOSURE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag