User manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR. We hope that this AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR user guide will be useful to you.

Lastmanuals help download the user guide AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR.


Mode d'emploi AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR
Download
Manual abstract: user guide AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR

Detailed instructions for use are in the User's Guide.

[. . . ] This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. [. . . ] 2 RTS1 Features The AXC-TEMP features include: !! Standard Axcess CardFrame slot size Settings for Fahrenheit or Celsius operation Control and power for up to four independent RTS1 units Measurement accuracy of +/- 2°F (+/- 1. 1°C) Calibration for zero temperature deviation The RTS1 features include: !! Precise temperature measurement from 5× to 128°F (-29. 2× to +106. 9°C) Connection to the AXC-TEMP card with a shielded 3-conductor cable AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor 1 Product Information The table below lists the specifications for the AXC-TEMP and RTS1. Specifications AXC-TEMP Input voltage Current Draw Temperature range Accuracy Resolution +12 to 18 VDC 40 mA (using four RTS1s = 75 mA) 0. 0 ° F to +250 ° F (0. 0 ° C to +106. 9 ° C) +/-2 ° F (+/-1. 1 ° C) 10-bit (1024 steps over range) RTS1 Weight Dimensions Enclosure Resolution Temperature range 3. 2 oz. (91 grams) 4. 5" x 2. 75" x 9" (114 mm x 70 mm x 23 mm) Metal, off-white finish 10-bit (1024 steps over range) -20. 5°F to +250°F (-29. 2°C to 106. 9°C) 2 AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor Pre-Installation Pre-Installation Before installing the AXT-TEMP and RTS1, you must properly set jumpers and potentiometers (POTs). Setting Fahrenheit or Celsius Set the Fahrenheit or Celsius feature by manually selecting each jumper (JP1- JP4) or by manually selecting the RAW A/D OUTPUT jumper on the card. 3 shows the location of the jumpers and POTs. The RAW A/D OUTPUT jumper overrides jumpers JP1 - JP4. Channels 1 - 4 Jumpers JP5 - JP8 Jumpers JP1 - JP4 and JP13 (RAW) FIG. 3 Location of jumpers and POTs Jumpers JP9 - JP12 Setting the Jumpers Use the two-position jumpers (FIG. 4) to select Fahrenheit or Celsius operation. The setting takes effect when you power on the system or reinsert the card into the CardFrame. The default setting is Fahrenheit (°F). °F °C JP1 FIG. Set each jumper (JP1 - JP4) on the card for either Fahrenheit or Celsius. Full counter-clockwise is a -4° variance and full clockwise is a +4° variance. To access the jumper and POTs, remove the AXC-TEMP card from the CardFrame. After making all adjustments, be sure to reseat the card properly. You can also adjust the card using an optional Axcess Extender Card (AXC-EXTN), for easier access. 3. Insert the card into the desired Axcess CardFrame slot. It is not necessary to disconnect power to the CardFrame when installing the card. AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor 3 Pre-Installation 4. Hold the card by the tab end and slide the card into the frame. Make sure the card is correctly positioned in the guide slot. Gently push the card in until it is firmly seated in the card connector slot. It is not necessary to disconnect the power to the CardFrame when installing the card. Calibrating POTs Use the four calibration potentiometers (POTs), marked CH 1 - CH 4, to adjust the respective RTS1 units 1 - 4. The default setting for each POT pointer is 0°. [. . . ] Allow the reference thermometer to stabilize approximately one minute, then check. If necessary, repeat steps 1 - 5 for RTS1 units 2 - 4, and move the reference thermometer near each sensor you are calibrating. 6 AXC-TEMP Temperature Control Card and RTS1 Room Temperature Sensor Pre-Installation Testing the RTS1 Touch the sensor at the bottom each RTS1 unit for a few seconds. The temperature on the display panel should change. Check the wiring to each RTS1 unit that did not display a temperature change. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE SENSOR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag