User manual AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS)
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS). We hope that this AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS) user guide will be useful to you.
Lastmanuals help download the user guide AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS).
Manual abstract: user guide AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS)
Detailed instructions for use are in the User's Guide.
[. . . ] instruction manual
Radia Lighting Control System
Controllers, Modules, and Cards
Lighting Controls
AMX Limited Warranty and Disclaimer
AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] The following table shows the SW1 DIP switch positions and their values. The device number assignment range is 1 through 255. SW1 DIP switch setting values for AXlink
Position 1 2 3 4 5 6 7 8 Value 1 2 4 8 16 32 64 128
1. Power off the enclosure unit at the breaker panel. Locate the SW1 DIP switch (AXLINK ADDRESS) on the controller circuit card and set the device number using the values shown in the proceeding table. Connect the four-pin AXlink male connector into the four-pin female AXlink connector on the controller circuit card. 20 shows how to wire the AXlink connector to a Central Controller system.
(optional)
+12V AXP/TX AXM/RX GND AXlink connector
+12V AXP AXM GND Central Controller
FIG. Apply power to the controller module at the breaker panel. Connecting dry closures AMX Lighting controller modules contain eight connections for dry contact closures, and one common reference point. 21 shows the standard wiring configuration for the 9-pin dry closure connector.
16
Radia Lighting Control System
Installation
1
2
3
4
5
6
7
8
C O M
9-pin Dry Closure Connector
FIG. 21 9-pin dry closure connector (standard configuration)
Each contact closure connection (1 through 8) is pre-programmed with a default preset. The following table shows the default presets for each contact closure. Dry closure default presets
Contact closure Default function 1 2 3 4 5 6 7 8 Channel 1 at 100% in 1 second* Channel 2 at 100% in 1 second* Channel 3 at 100% in 1 second* Channel 4 at 100% in 1 second* Channel 5 at 100% in 1 second* Channel 6 at 100% in 1 second* Pack on (channels 1-6)* Pack off (channels 1-6)*
*All other channels are undefined.
Default Mode (Reset)
Default mode is resetting the AMX Lighting module values to zero and the module then begins to function on the values you previously programmed into the module. If you experience problems after installing a lighting system, you may need to reset the controller module to default mode. Then, you should be able to determine if there is a problem with the connections, programming, and/or dimming. To reset a AMX Lighting controller to default mode: 1. Power off the AMX Lighting enclosure at the circuit breaker panel. Disconnect all AXlink and PROlink cables from the controller module. Connect a jumper to the dry contact closures 1 through 8 and to ground as shown in FIG. 22.
C O 8M
1
2
34
5
6
7
9-pin Dry Closure Connector
FIG. 22 9-pin dry closure connector set to default mode
Radia Lighting Control System
17
Installation
4. Power up the controller enclosure and wait for the controller's green status LED to go off after approximately 1 minute. [. . . ] Scene - The condition or status of all dimmers in a designated area or zone. A preset recalled and then changed becomes a scene. Slot - A single space in a Radia Lighting enclosure numbered from left to right starting at #1. This is used to describe which space in an enclosure a module is located or installed. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS)
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX RADIA LIGHTING CONTROL SYSTEM (CONTROLLERMODULESCARDS) will begin.