User manual AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE. We hope that this AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE user guide will be useful to you.

Lastmanuals help download the user guide AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE.


Mode d'emploi AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE
Download
Manual abstract: user guide AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Sheet RDC-PDC Control Card, Dual or Three Phase (120 or 240 VAC) The RDC-PDC Control Card module controls up to six dimmable channels with six satellite connectors (for RDM series dimmer or switching modules). The RDC-PDC is controlled by AXlink, PROlink, or by dry contact closures. The RDC-PDC is designed for use with Radia enclosures, in a modular digital dimming system. [. . . ] Use low-voltage wires with a 300 volt rating or greater. All electrical ratings are for continuous duty. AC lighting loads only. Line inputs (factory wired) Connecting RDM Series to the AMX Lighting Master Pin 4 (GND) Pin 3 (RLY) Pin 2 (DIM) Pin 1 (+12 V) RDC-PDC 4-pin module connector Reset button Memory Protect jumper 4-pin plug from a RDM series module AXlink connector LED indicators Dry closure contacts PROlink connector FIG. 2 Connecting RDM series Note: The 4-pin plugs from the module connector to the 4-pin connector on the master (black plug cover facing up). AXlink DIP switch PROlink DIP switch Connecting AXlink Control ports Connect the 4-pin captive-wire AXlink connector from the RDC-PDC to the Central Controller for AXlink control of the dimming system. PWR RDC-PDC AXP AXM GND (optional) PWR AXP AXM GND FIG. 1 RDC-PDC control card RDC-PDC UL and C-UL Ratings: Control Input: · AXlink · PROlink · Eight dry closures Control Output: · Six control ports · Max. total control current at 300 mA Power Inputs: · Line 1 (channel 1 and 4) · Line 2 A (channel 5) · Line 2B (channel 2) · Line 3 (channel 3 and 6) · Neutral Central Controller FIG. 3 AXlink wiring Connecting PROlink: Connect the orange 4-pin captive-wire PROlink connector from the RDCPDC to a PRO-DP8 PROlink wall panel. PRO-DP8 +12 PR+ PRGND FIG. 4 PROlink wiring Pack 1 Pack 2 +12 PR+ PRGND Specifications: · · · · · · · Dimensions (HW): 10. 0" x 2. 75" (254. 0 mm x 69. 85 mm) 12 VDC power (optional) Torque terminals to 20 in-lbs. wire size: 10 AWG Wire stripping length: 0. 28" (7 mm) Weight: 1. 5 lbs. (0. 68 kg) Power consumption: 50 mA @ 120 VAC 25 mA @ 240 VAC Connecting Dry Closures Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel. 1 2 3 4 5 6 7 8 COM Each contact (1 - 8) is preprogrammed with a default preset. Refer to the AMX Lighting Control System instruction manual for details on dry closure default presets and recording new presets. 5 Dry closures connection Dry Closure Default Presets (Cont. ) 5 6 7 8 Channel 5 at 100% in 1 second Channel 6 at 100% in 1 second Pack on (channels 1-6) Pack off (channels 1-6 All other channels are undefined. Setting AXlink and PROlink Address Numbers: AXlink Address PROlink Address Test Each contact closure connection (1 - 8) is pre-programmed with a default preset. The table below shows the default presets for each contact closure. Dry Closure Default Presets Contact Closure 1 2 3 4 Default Function Channel 1 at 100% in 1 second Channel 2 at 100% in 1 second Channel 3 at 100% in 1 second Channel 4 at 100% in 1 second Set the AXlink address number (1-255) for the RDC-DC. [. . . ] The AMX logo is a trademark of AMX Corporation. AMX Corporation reserves the right to alter specifications without notice at any time. 3000 research drive, richardson, TX 75082 USA · 469. 624. 8000 · 800. 222. 0193 · fax 469. 624. 7153 · technical support 800. 932. 6993 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX RDC-PDC RADIA PRO CONTROL CARD, DUAL OR 3 PHASE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag