User manual AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE. We hope that this AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE user guide will be useful to you.

Lastmanuals help download the user guide AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE.


Mode d'emploi AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE
Download
Manual abstract: user guide AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Sheet RDD-DM4 4-Channel Integrated Dimmer Module 120, 240, 277 VAC The RDD-DM4 Four-Channel Integrated Dimmer Module controls up to six dimmed channels with four 1200 W onboard dimmers and two satellite connectors (for RDM series dimmer or switching modules). It is designed for use with the RDA series of enclosures, in an AMX LightingTM modular digital dimming system. The RDD-DM4 is controlled by AXlink, PROlink, or by dry (contact) closures. [. . . ] Use low-voltage wires with a 300 volt rating or greater. All electrical ratings are for continuous duty. This module may require extra power from the AXlink connection or an external power supply connected to the control card. Connecting the RDD-DM4 to the AMX Lighting Master Pin 4 (GND) Pin 3 (RLY) Pin 2 (DIM) Pin 1 (+12 V) RDD-DM4 4-pin module connector 3 (-) 1 (+) 4-pin plug from RDM series module NOTE: The 4-pin plugs from the module connector to the 4-pin connector on the master (black plug cover facing up). Dry Closures AXlink connector PROlink External +12 V power connector (optional) FIG. 1 RDD-DM4 4-channel Integrated Dimmer Module RDD-DM4 UL and C-UL Ratings: (per circuit) Input · 120, 240, 277 VAC, single phase, 3-wire, 50/60 Hz, 2400 W, one feed · 120 , 240, 277 VAC, single phase, 4-wire, 50/60 Hz, 4800 W, dual feed Output · · · · 1200 W max. per channel @120, 240, 277 VAC 2400 W max. total, all four channels on with 2400 W feed 4800 W max. total, all four channels on with dual 2400 W feeds Feed circuit #1 goes to dimmer 1 and 3; feed circuit #2 goes to dimmer 2 and 4. FIG. 2 RDD-DM4 connections Connecting AXlink: Connect the 4-pin captive-wire AXlink from the RDD-DM4 to the Central Controller for AXlink control of the dimming system. PWR RDD-DM4 AXP AXM GND (optional) PWR AXP AXM GND Specifications · · · · · · · · Dimensions (HW): 5. 87" x 10. 0" (149. 00 mm x 254. 00 mm) Use wires rated at 75°C (167°F) Torque terminals to 20 in-lbs (2. 3 N/M) Max. wire size: 10 AWG (4 mm²) Wire stripping length: 0. 35" (9 mm) Weight: 4. 5 lbs (2. 04 kg) BTU/hr: 300 single feed (2400 W); 600 dual feed (4800 W) Power consumption: 50 mA @ 120 VAC, 25 mA @ 240 VAC, 22 mA @ 277 VAC · Control port current: 200 mA @ 12 VDC Central Controller FIG. 3 Connecting AXlink Connecting PROlink: Connect the orange 4-pin captive-wire PROlink connector from the RDD-DM4 to a PRO-DP8 PROlink wall panel. PRO-DP8 +12 PR+ PRGND Pack 1 Pack 2 +12 PR+ PRGND FIG. 4 Connecting PROlink Line-in Connections: Dual 20 A Inputs Using two feeds for line 1 and line 2 provides two, 20 A inputs. Dry Closure Default Presets Contact Closure 1 2 Bridging line 1 and line 2 provides a single 20 A input. 3 4 5 Default Function Channel 1 at 100% in 1 second Channel 2 at 100% in 1 second Channel 3 at 100% in 1 second Channel 4 at 100% in 1 second Channel 5 at 100% in 1 second Channel 6 at 100% in 1 second Pack on (channels 1-6) Pack off (channels 1-6 All other channels are undefined. 20 A Bridged 20 A Input FIG. 5 Line-in Connections 6 7 8 Connecting Dry Closures: Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel. 1 2 3 4 5 6 7 8 COM Each contact (1 - 8) is preprogrammed with a default preset. Refer to the AMX Lighting Control System instruction manual for details on dry closure default presets and recording new presets. Setting AXlink and PROlink Address Numbers: AXlink Address PROlink Address Test FIG. [. . . ] The AMX logo is a trademark of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. 3000 research drive, richardson, TX 75082 USA · 469. 624. 8000 · 800. 222. 0193 · fax 469. 624. 7153 · technical support 800. 932. 6993 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX RDD-DM4 4-CHANNEL INTEGRATED DIMMER MODULE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag