User manual APPLIED ENERGY LVCF20T DC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APPLIED ENERGY LVCF20T DC. We hope that this APPLIED ENERGY LVCF20T DC user guide will be useful to you.

Lastmanuals help download the user guide APPLIED ENERGY LVCF20T DC.


Mode d'emploi APPLIED ENERGY LVCF20T DC
Download
Manual abstract: user guide APPLIED ENERGY LVCF20T DC

Detailed instructions for use are in the User's Guide.

[. . . ] GUARANTEE Terms and Conditions for UK & ROI (outside UK & ROI contact your local distributor) We, Applied Energy Products Limited, guarantee this product for residential use only, for the period of 5 years from the date of purchase subject to the following conditions ­ initial 3 years parts and labour, final 2 years parts only. Within the guarantee period we will resolve, free of charge, any manufacturing defects in the product resulting from faulty workmanship or material on condition that:a) The appliance has been correctly installed in accordance with our instructions and is being used on the supply circuit or voltage printed on the rating plate. b) The appliance has been used in accordance with these instructions and has not been tampered with or otherwise subject to misuse, neglect or accident. c) The appliance has been regularly maintained in accordance with these instructions and the airway is unobstructed. [. . . ] Ensure the circular spigot enters the ducting. Fix the fan box to the wall using screws or to the ceiling using appropriate fasteners. Mounting fan in a wall (flush mounting) For flat ducting: · This fan can be installed within a 140mm void with the circular spigot (Fig. C) Fit the foam tape supplied around the circular spigot Remove the electrical cover (Fig. Fit the ducting to the circular spigot . G . 1. 3. Installing the fan on a wall (surface mounting) Mark on the wall the centre of the duct hole A. Use this centre to cut an opening 117mm diameter with a slight fall to the exterior. Fit and mortar the wall tube (not supplied). Installing fan in a wall (flush mounting) 5. H 1. 6. Mark on the wall the centre of the duct hole A, and drill a pilot hole through both walls. Use the duct centre to mark a rectangular hole for the inner wall using the dimensions A. Cut the rectangular hole through the inner wall. Go outside and cut a 117mm diameter hole in the outer wall using the small hole as the centre. Cut the wall tube (WD100), not supplied, so that it is 85mm less than the wall thickness. Installing fan on a ceiling (surface mounting) Requires a space above the ceiling, such as a loft or attic, to provide access for 100mm diameter ducting, or a minimum 70mm void using flat ducting. Mark on the ceiling the centre of the duct hole A, avoiding ceiling joists and buried cables etc. Installing fan in a ceiling (flush mounting) For 100mm diameter ducting: Requires a space above the ceiling, such as a loft or attic, to provide access for 100mm diameter ducting. Mark a rectangular hole using the dimensions B. Cut the hole, avoiding ceiling joists and buried cables etc. 6. 7. Ancillary Options For speed and ease of installation, your installation may require some of the Ancillaries listed below: WD100 XCT100 DGW/B SP100 XAA VC10 WT10 XFP Wall Duct Condensation Trap Air Replacement Grille Spigot Plate Air Brick Adaptor Vent Cowl Termination Ducting Kit Flat Ducting (Plastic 234x29) VK10 FD100 WDC5 XCMK XBP EFT GMK PDXGF Wall Vent Kit Flexible Ducting Worm Drive Clips Ceiling Mounting Kit In-Line Back Draught Shutter Easy Fit Termination Kit Glass Mounting Adaptor Grease Filter If the hole size is as recommended: 1. Assemble the three fan body clamps to the fan box using screws . Pass the electrical cables into the fan box through the cable inlet hole and cable grommet. [. . . ] Condensation Operation The fan operates at condensation control speed, when the relative humidity exceeds the set level, and turns off when the humidity drops. Boost Operation The integral pull cord switch switches the fan to run at high speed. Bottom light "II" is lit when the fan is operating at high speed. Note: If the separate on/off switch and integral pull cord are both on, the lights "I" and "II" will both be lit and the fan will run at high speed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY LVCF20T DC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY LVCF20T DC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag