User manual APRIMATIC T1E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APRIMATIC T1E. We hope that this APRIMATIC T1E user guide will be useful to you.

Lastmanuals help download the user guide APRIMATIC T1E.


Mode d'emploi APRIMATIC T1E
Download
Manual abstract: user guide APRIMATIC T1E

Detailed instructions for use are in the User's Guide.

[. . . ] No part of this document may be reproduced or translated into any other language or form without the written permission of Aprimatic S. The product specifications may be modified without prior notice. Therefore this document may not correspond exactly to the characteristics of the product. The installer must check the installation and the correct functioning of the device. [. . . ] This operating mode requires the physical presence of a human operator, who opens and closes the gate and the input of terminal 6 is used as the closing start (use a N. To open the gate, press the start push-button and hold it down (opening input). When the push-button is released, the gates are blocked. To close the gate, press the close push-button and hold it down; if the photocells are obscured, the device blocks the gates. In this case, the operator must release the push-buttons and press either close or open. This is also the case if the two push-buttons are pressed at the same time. If you select this operating mode, when a pulse is given, opening is commanded until the work time expires, the gate remains open for the selected pause time and it then closes automatically. â· If a pulse is sent during opening, the control system ignores it and the gate continues to open. â· If a pulse is sent or the photocells are obscured during closing, the direction is inverted (the gate re-opens). â· During the pause stage and when the photocells are obscured, the device will remain in pause until the photocells are cleared. If you select this operating mode when the gate is closed, when a start pulse is given, the gates open until the set work time expires. If another start pulse is given during opening, the gates stop immediately until another start pulse is given: this closes the automation. When you select this type of operating and a start pulse is given, the gate opens as far as the limit switch and stays open for the pre-set pause time and then closes automatically. A start pulse given during any stage reverses the direction: you can close the gate with a command. DIP-SWITCHES 4 and 5 (GATE CLOSING DELAY) - These SWITCHES are used to adjust the gate closing delay for motor 1 (delayed closing), compared to the start up of motor 2 (immediate). It is possible for both the opening and closing stages. If the function is enabled, before the automation opens or closes, there will be a signal for 3 seconds and the warning light and flashing lights will come ON before the gates move. DIP SWITCH 7 (PAUSE PHOTOCELL) - This SWITCH is used to select the pause photocell function when the automatic functioning mode is enabled. When the SWITCH is in the ON position, if the photocell beam is interrupted and cleared with the automation in pause, the device will command pre-flashing for 3 seconds and will then close the gate, even if the pause time has not been concluded. When the SWITCH is in the OFF position, the gate will only close when the set pause time expires. When the SWITCH is in the ON position, the input functions as an opening safety device. When the SWITCH is in the OFF position, the input is enabled for single wing functioning (motor 1). [. . . ] It closes the automation when the close push-button is pressed and held down. nOTE - The selection of one function disables the other functions. Electric lock output - 12 VAC output with maximum load of 15W, which commands the electric lock for approximately 1. Warning light output - 24VDC output with maximum load of 3W, which commands the gate state warning light. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APRIMATIC T1E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual APRIMATIC T1E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag