User manual ARTHUR MARTIN 34942G-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ARTHUR MARTIN 34942G-M. We hope that this ARTHUR MARTIN 34942G-M user guide will be useful to you.

Lastmanuals help download the user guide ARTHUR MARTIN 34942G-M.


Mode d'emploi ARTHUR MARTIN 34942G-M
Download
Manual abstract: user guide ARTHUR MARTIN 34942G-M

Detailed instructions for use are in the User's Guide.

[. . . ] 34942G Gas hob Operating Instructions GB Important Safety Information You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 350 350 Installation This hob must be installed by qualified personnel, according to the manufacturer's instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Remove all packaging before using the hob. [. . . ] After cleaning, be sure to wipe dry with a soft cloth. 8 Something Not Working? If the hob is not working correctly, please carry out the following checks before contacting your local Service Force Centre. SYMPTOM There is no spark when lighting the gas SOLUTION Check that the unit is plugged in and the electrical supply is switched on Check that the RCCB has not tripped (if fitted) Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly, e. g. Check the main jet is not blocked and the burner crown is clear of food particles. Check the burner cap and crown have been replaced correctly, e. g. after cleaning. The gas ring burns unevenly If after all these checks, your hob still does not operate correctly, contact your local Service Force Centre. Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown. 9 Service and Spare Parts If you require spare parts or an engineer contact your local Service Force Centre by telephoning: 0870 5 929 929 Your call will be routed to your local Service Force Centre. For the address of your local Service Force Centre and further information about Service Force, please visit the website at www. serviceforce. co. uk When you contact the Service Centre, they will need the following information: 1. · Appliances found to be in use within a commercial environment, plus those which are subject to rental agreements. · Products of AEG-Electrolux manufacture which are not marketed by AEG-Electrolux. European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: · · · · · · The guarantee starts from the date you first purchased your product. The guarantee is for the same period and to the same extent for labour and parts as exists in the new country of use for this brand or range of products. This guarantee relates to you and cannot be transferred to another user. Your new home is within the European Community (EC) or European Free Trade Area. The product is installed and used in accordance with our instructions and is only used domestically, i. e. The product is installed taking into account regulations in your new country. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Germany Italy Sweden UK Senlis Nürnberg Pordenone Stockholm Slough +33 +49 +39 +46 +44 (0)3 44 62 29 29 (0)800 234 7378 (0)800 117511 (0)8 672 53 60 (0)1753 219899 11 Instructions for the Installer Engineers technical data OVERALL DIMENSIONS Width: Depth: Height: Weight: 860 mm 500 mm 88 mm 16 Kg CUT OUT DIMENSIONS Width: 830 mm Depth: 470 mm Thickness: 30 mm SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V 50 Hz, 220 V 60 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. HEAT INPUT Rear Left Burner (semi rapid) Front Left Burner (rapid) Central Burner (triple-crown) 2. 0 kW (6824 BTU/HR) 3. 0 kW Natural Gas (10236 BTU/HR) 2. 8 kW L. P. G. (9554 BTU/HR) 4, 0 kW (13652 BTU/HR) Rear Right Burner (semi rapid) 2. 0 kW (6824 BTU/HR) Front Right Burner (auxiliary) APPLIANCE CLASS APPLIANCE CATEGORY GAS SUPPLY 1. 0 kW (3412 BTU/HR) 3 II2H3+ Natural gas G20 / 20 mbar 12 Instructions for the Installer BURNER TYPE OF GAS POSITION NOMINAL THERMAL POWER (kW) RAPID (large) MAX MIN SEMI-RAPID A U X I L I A R Y (medium) (small) MAX MIN MAX MIN TRIPLE CROWN MAX MIN NATURAL GAS NOMINAL FLOW 20 mbar VALUE = RATE (m3/h) 37. 78 MJ/m3 Ws - 50. 7 MJ/ m3 NOZZLE REFERENCE (1/100 mm) 3. 0 0. 65 2. 0 0. 45 1. 0 0. 33 4. 0 1. 2 0. 286 0. 057 119 Adjust. 0. 190 0. 038 0. 095 0. 028 0. 381 0. 114 96 Adjust. 146 Adjust. LPG GAS NOMINAL THERMAL 28-30/37 mbar POWER (kW) VALUE= NOMINAL FLOW 49. 92MJ/Kg RATE (g/h) NOZZLE REFERENCE (1/100 mm) 2. 8 202 86 0. 65 43. 5 40 2. 0 144 71 0. 45 29 32 1. 0 72 50 0. 33 21, 5 28 4. 0 252 98 1. 2 86 56 Burner Dia. Tap By-pass 1/100 mm 28 32 40 56 Auxiliary Semi-rapid Rapid Triple-Crown Aeration adjustment none 13 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. [. . . ] If meter reads «0» then there is a short circuit. b) meter set on ý (Ohm) x 100 scale. If meter reads less than × (infinity) there is a fault. NOTE - Should it be found that the fuse has failed but no fault is indicated a detailed continuity check (i. e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ARTHUR MARTIN 34942G-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ARTHUR MARTIN 34942G-M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag