User manual ASKO D1996

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ASKO D1996. We hope that this ASKO D1996 user guide will be useful to you.

Lastmanuals help download the user guide ASKO D1996.


Mode d'emploi ASKO D1996
Download

You may also download the following manuals related to this product:

   ASKO D1996 QUICK START GUIDE (65 ko)

Manual abstract: user guide ASKO D1996

Detailed instructions for use are in the User's Guide.

[. . . ] Maximum of 4" from the back wall and 8" from the floor. There cannot be any electrical connections in this area. *24" from fill strip to fill strip. **23-7/16" depth includes space for high-loop drain hose. For standard NON-raised panels, use 1/16" up to 1/4" material. For custom raised panels, the decor trim will accept up to 1/4" flange. [. . . ] A black toe kick can be purchased separately, if desired. (See dealer. ) If the homeowner prefers, the toe kick can be covered with the same baseboard used in the kitchen. It is not recommended that the baseboard running in front of the unit and the cabinets be one continuous piece. Should the unit ever have to be removed, it is much easier if the baseboard in front of the dishwasher can be removed separately. These units have a special locking system so they can be installed with a custom panel. This panel can match the cabinets, with a drawer front, a cabinet door and matching hardware. It is recommended that a handle be used for opening the dishwasher. They come with everything needed to make the installation easy. The dishwasher's door is pre-drilled for the panel's mounting screws. The Turbo Fan Interval Drying System's vent is adjustable and must extend below the custom panel. The lower access panel has been eliminated to give the unit its single door appearance. See the Dishwasher Installation Instructions for detailed information. 9 4" Toe Kick Installations ­ D1796FI and D1996FI with Custom Panel Door Where the custom panel's height matches the dishwasher's door, a 2" decorative fill strip or cutting board must be used to fill the area between the panel and the counter top (A). For this installation, the custom door panel dimensions are 23-1/2" wide x 28-1/8" high. The opening width is 23-3/4", 3/8" narrower than standard domestic dishwashers. (A) 2" decorative fill strip or cutting board required There will be a 1-3/4" height difference between controls and panel. (B) 28-1/8" 23-1/2" 4" Custom panel extends 2" beyond/above dishwasher door. Custom panel goes from toe kick to counter top: 23-1/2"w x 30-1/8"h. 30-1/16" 23-1/2" 4" 23-3/4" Another installation option for 4" toe kick cabinets is to extend the door panel 1-3/4" above/beyond the control panel (B). This eliminates the need for a 2" decorative fill strip. This door panel is 23-1/2" wide x 30-1/8" high (two inches higher than previous option). This also means a 2" support strip must be installed between the tank and the counter top to fill the gap. Even though, like all ASKOs, the D1796FI and D1996FI can be mounted with screws going through the sides, this support strip can also be used for anchoring the unit from the top. A popular and more finished looking installation is to use the metal top fill strip shown in Dishwasher Accessories (page 7). It fills the gap between the top of the tank and the counter top. [. . . ] When used with custom panels, the panel's height must be reduced by the height of the spacers. Electrical And Water Requirements ­ All Dishwashers Electricity and water can enter the opening on either side within an area 4" from the back and 8" from the floor. They should run from the back along the right side. The supply line connects to the hot water supply with 3/8" OD copper tubing. A 3/8" NPT female connection attaches to the fill valve. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ASKO D1996

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ASKO D1996 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag