User manual ATIKA COMET 130 S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ATIKA COMET 130 S. We hope that this ATIKA COMET 130 S user guide will be useful to you.

Lastmanuals help download the user guide ATIKA COMET 130 S.


Mode d'emploi ATIKA COMET 130 S
Download

You may also download the following manuals related to this product:

   ATIKA COMET 130 S BROCHURE (2405 ko)

Manual abstract: user guide ATIKA COMET 130 S

Detailed instructions for use are in the User's Guide.

[. . . ] Observe local accident prevention and safety regulations in the work area. Do not touch, inhale (dust development) or eat the cement or additives. Wear personal, protective clothing (gloves, goggles and a dust mask) when filling and emptying the mixing drum. Set up and run the concrete mixer on a solid, level base only (where it will not tip over). [. . . ] Concrete mixer with threephase motor After switching on the machine, you must check the mixing drum's direction of rotation. When you look into the mixing drum, it must turn to the left (counter-clockwise). If the mixing drum turns in the opposite direction from the arrow, the rotating direcion can be changed by inderting a screwdriver for this purpose and turn left or right while exerting a light pressure to adjust the correct rotating direction. Danger to life and limb if not observed! Connecting attachments must be designed in conformance with IEC 60245-4:1980 (DIN 57 282) and marked H 07 RN-F, or comparable models. Use only connecting attachments with a rubber plug for severe requirements that is protected device against spraying water. When laying the connecting attachments, be sure that they do get crushed or bent, and that the plug-and-socket connection does not get wet. Do not use any provisional electrical connections. Never bridge over protective devices or put them out of operation. Observe the following instruction in Switzerland: Only hook up locomotive units used outdoors by means of a fault-current circuit breaker. Mixer setting: To make concrete or mortar, the mixing drum must be locked in a specific position. Only the proper mixer setting ensures optimal mixing results and smooth operation. Concrete mixer with adjusting disc Rotating level Handwheel A licensed professional electrician must make all electrical connections and repairs, and observe local regulations in doing so, especially those regarding protective measures. The manufacturer or a company designated by the manufacturer must attend to the repair of all electrical parts on the machine. Keep the machine from sinking into the ground or floor. When setting up the machine, make sure that the mixing drum can be emptied without obstruction. Allow rotating mechanism to lock into place. Point the opening of the mixing drum downwards during transport or storage. Concrete mixer with brake Hold handwheel tightly while rotating. Step on the brake Rotate the mixing drum up to the marking appropriate for the material you are mixing release brake · In order to increase the service life of the concrete mixer and operate it without glitches, the rotating mechanism should be treated with an environmentally compatible spray oil before the mixer is put into storage for unusually long periods. Switch off machine and pull plug if you have to touch the machine (with hand, brush, scraper, rag, etc. Protective devices removed for cleaning must be properly remounted before starting the machine. [. . . ] Only the manufacturer or companies authorised by the manufacturer may perform repair work on electrical parts or on parts which affect the space needed to mount electrical equipment. Use only unaltered original spare parts. Malfunction Motor does not start up Possible cause no mains voltage defective cable thermostat is triggered reason: - motor overload - motor not getting enough air owing to clogged ventilation apertures Motor hums but does not blocked crown gear start up defective condenser Remedy check fuse protection have checked or replaced (electrician) allow motor to cool and then find and eliminate whatever caused the thermostat to respond Switch off machine, pull plug and clean or replace the crown gear segments send machine to manufacturer or a company designated by the manufacturer for repairs Machine starts up, but extension cord is too long or its cross-section extension cord must be at least 1. 5 mm² for a becomes blocked at low is too small maximum length of 25 m; the cross-section load and may switch off socket is too far from mains connection and of longer cables must be at least 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ATIKA COMET 130 S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ATIKA COMET 130 S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag