User manual AUDIOVOX 1286469

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AUDIOVOX 1286469. We hope that this AUDIOVOX 1286469 user guide will be useful to you.

Lastmanuals help download the user guide AUDIOVOX 1286469.


Mode d'emploi AUDIOVOX 1286469
Download
Manual abstract: user guide AUDIOVOX 1286469

Detailed instructions for use are in the User's Guide.

[. . . ] Model APS-410a Installation Manual RF Programmable Features : Feature Selection 1st Door L/UL 2nd Accy Lock 3rd Accy. UL 4th Non Functional 5th Passive Locks 6th Passive/Active Arm 7th Voltage Sense 8th Siren/Horn 9th Horn Chirp 10th Override Method 11th Two Step Unlock 12th Chirp Delete From Tx Passive Passive Arm Voltage Sense Siren/Horn 10mS Custom Code On On Active Active Arm Hardwire Siren Only 16mS Valet Off Off Horn Only 30mS 1 Chirp 1 Sec. Auto Lock On Auto UL Dr 2 Chirps 3. 5 Sec. Auto Lock Off Auto UL All Auto UL Off 3 Chirps 1 Sec L, Dbl. [. . . ] Connecting the dark green w/ black trace wire to the high current switched output of trunk release circuits will damage the control module. Connect the dark green w/ black trace wire to terminal 86 of the AS 9256 relay (or an equivalent 30 Amp automotive relay ), and wire the remaining relay contacts to perform the selected function of channel 4. Dark Blue w/Black Trace Wire: Alternate Channel 3 Output (Dbl. Push Required) This wire is controlled from the transmitter button programmed to the receiver's channel 3. By double pressing the transmitter button, this output will become active for 1 second. This is a transistorized, low current ( 300 mA ) output, designed to provide an output only when the transmitter is intentionally operated, such as is the case with remote start add on modules. If you require more than 300mA drive from this output, you must drive an external relay coil, and arrange the relays contacts to preform the specified function. NOTE: Pressing the transmitter button, then immediately pressing and holding it will cause this output to be active as long as the transmitter button is depressed. Black w/ White Trace Wire: 300 mA Horn Output The black w/ white trace wire is provided to beep the vehicle's horn. This is a transistorized low current output, and should only be connected to the low current ground output from the vehicle's horn switch. If the vehicle uses a + 12 VDC horn switch, then connect the black w/ white trace wire to terminal 86 of the AS 9256 relay (or an equivalent 30 Amp automotive relay ), and connect relay terminal 85 to a fused Page 4 128-6469 4 of 8 + 12 VDC battery source. Yellow Wire: + 12 VDC IGNITION SOURCE Connect this wire to a source that is live when the key is in the on and crank positions. Be sure that this source is off when the key is in the off position. 2 Pin Blue Connector: VALET SWITCH Route the grey and black wires in the 2 pin connector from the valet switch to the control module, and plug it into the mating blue connector on the side of the module. 2 Pin White Connector: DASH MOUNTED LED Route the red and blue wires in the 2 pin white connector from the LED to the control module, and plug it into the mating white connector on the side of the module. 4 Pin White Connector : SHOCK SENSOR Route the red, black, blue, and green wires in the 4 pin white connector from the shock sensor to the control module, and plug one end into the shock sensor, and the other end into the mating white connector on the side of the module. Red / Green / Red w/Black Trace 3 Pin White Connector : Door Lock Outputs The Red and Green wires will provide either a pulsed ground output to the factory door lock control relay, or a pulsed + 12 volt output to the factory door lock control relay. In either case, the maximum current draw through these outputs must not exceed 300 mA. The Red w/Black trace wire will provide a pulsed ground only, and will only provide an output when the unlock button of the transmitter is pressed a second time after a first unlock command was issued. This is used for second step unlock or all doors unlock in a two step circuit. In this arrangement, Red, or Green is used to control the drivers door unlock relay, and the Red/Black will be used to control unlock of all other doors. 3 Wire Ground Switched Single Step Door Locks In this application, the red wire provides a ground pulse during arming, or the pulsed ground lock output. [. . . ] To learn the light delay, start with all doors closed: (1) Use the transmitter to Lock / Unlock / Lock / Unlock / Lock / Unlock / Lock, the system. The LED turns on solid to confirm the system entered the learn mode. (2) Immediately open and close the door of the vehicle to initiate the dome delay. The unit will monitor the door trigger input Positive, (Purple), and Negative, (Brown) when active. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AUDIOVOX 1286469

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AUDIOVOX 1286469 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag