User manual AUDIOVOX 1286994

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AUDIOVOX 1286994. We hope that this AUDIOVOX 1286994 user guide will be useful to you.

Lastmanuals help download the user guide AUDIOVOX 1286994.


Mode d'emploi AUDIOVOX 1286994
Download
Manual abstract: user guide AUDIOVOX 1286994

Detailed instructions for use are in the User's Guide.

[. . . ] Model AX-200 Installation Manual SELECTABLE FEATURES Note: When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver's door pin switch in order to begin the passive arming sequence. RF Programmable Features: Feature Selection 1st Door L/UL 2nd Accy Lock 3rd Accy. UL 4th Passive Locks 5th Passive/Active Arm 6th Voltage Sense 7th Siren/Horn 8th Horn Chirp 9th Override Method 10th Two Step Unlock 1 Chirp 1 Sec. Passive Passive Arm Voltage Sense Siren/Horn 10mS Custom Code On 2 Chirps 3. 5 Sec. Auto Lock Off Auto UL All Active Active Arm Hardwire Siren Only 16mS Valet Off Off Horn Only 30mS Auto UL Off 3 Chirps 1 Sec L, Dbl. [. . . ] Connect relay terminal 85 to an ignition wire in the vehicle that is live when the key is in the on and crank positions, and off when the key is in the off position. ( This is where the yellow wire from the alarm should be connected ). Cut the low current starter solenoid wire in the vehicle, and connect one side of the cut wire to relay terminal 87A. Connect the other side of the cut wire to relay terminal 30. Note: This is a normally closed starter cut arrangement and when power is removed from the security system, the starter disable feature will not operate, allowing the vehicle to start. The Manufacturer does not recommend using the Orange wire to interrupt anything but the starting circuit of the vehicle. Brown w/Black Trace Wire: LOW CURRENT NEGATIVE HORN OUTPUT (300mA MAX CURRENT) This wire provides a 300mA pulsed output to beep the vehicle's horn. This low current pulsed output should only be connected to the low current switched ground output from the vehicle's horn switch. If the vehicle switches high current ground or + 12 volts to the horn, a relay must be used to operate the vehicle horn. Connect the Brown/Black wire to terminal #86 of a VF45F11 P&B or equivalent 30A automotive relay. Connect terminal #85 to a fused + 12 volt source. Connect the remaining relay contacts 87, 87a and 30 to perform the switching function the vehicle's horn circuit requires. White w/Green Trace Wire: Activation Output (Dbl. Push Required) This wire is controlled from the transmitter button programmed to the receiver's channel 2. By double pressing this the transmitter button, this output will become active for 1 second. This is a transistorized, low current ( 300 mA ) output, designed to provide an output only when the transmitter is intentionally operated, such as is the case with remote start add on modules. If you require more than 300mA drive from this output, you must drive an external relay coil, and arrange the relays contacts to preform the specified function. Black w/ White Trace Wire: Entry Illumination ( 300 mA max. ) This wire provides a 30 second ground signal whenever the system is disarmed, and pulses ground whenever the system is triggered. It should be used to provide the ( optional ) entry lighting and to flash the vehicle's dome light while the alarm is sounding. This is a transistorized, low current output and should only be used to drive an external relay coil. 3 Wire Ground Switched Single Step Door Locks In this application, the green wire provides a ground pulse during arming, or the pulsed ground lock output. [. . . ] If the vehicle has delay interior lights, and you wish to avoid three chirp, defect zone, indication normally associated with this type of interior light, we suggest you learn the interior light delay. To learn the light delay, start with all doors closed: (1) Use the transmitter to Lock / Unlock / Lock / Unlock / Lock / Unlock / Lock, the system. The LED turns on solid to confirm the system entered the learn mode. (2) Immediately open and close the door of the vehicle to initiate the dome delay. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AUDIOVOX 1286994

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AUDIOVOX 1286994 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag