User manual AVDEL GENESIS NG4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AVDEL GENESIS NG4. We hope that this AVDEL GENESIS NG4 user guide will be useful to you.

Lastmanuals help download the user guide AVDEL GENESIS NG4.


Mode d'emploi AVDEL GENESIS NG4
Download
Manual abstract: user guide AVDEL GENESIS NG4

Detailed instructions for use are in the User's Guide.

[. . . ] Safety Instructions Specifications Tool Specification Tool Dimensions Intent of Use Range of Fasteners Part Numbering Putting into Service Air Supply Operating Procedure - All fasteners except Avtainer® and Maxlok® Operating Procedure - Avtainer® and Maxlok® Nose Assemblies Nose Tip Selection Fitting Instructions - All Nose Assemblies except Avtainer® and Maxlok® Nose Tips Type 1 Standard Avseal® II Nose Tip Type 2 Limited Access Type 3 Aerospace Type 6 Hemlok®/Interlock® Type 5 Avtainer® Maxlok® Fitting Instructions for Avtainer® and Maxlok® Nose Assemblies Servicing Instructions for all Nose Assemblies Accessories Stem Deflector Preparing the Base Tool for use with Stem Deflector Extension 4 Servicing the Tool Daily / Weekly Moly Lithium Grease EP 3753 Safety Data Molykote® 55m Grease Safety Data Molykote® 111 Grease Safety Data Service Kit Maintenance Nose Equipment Dismantling the Tool Head Assembly Pneumatic Piston Assembly Air Valve Rotary Valve Trigger Stop Plate Assembly (71213-03900) General Assembly of Base Tool General Assembly Parts List Priming Oil Details Hyspin® VG 32 Oil Safety Data Priming Kit Priming Procedure Fault Diagnosis Symptom, Possible Cause and Remedy Français Deutsch Italiano 15 15 15 16 16 17 17 18 18 18 19 19 20 20 21 21 22 LIMITED WARRANTY Avdel makes the limited warranty that its products will be free of defects in workmanship and materials which occur under normal operating conditions. This Limited Warranty is contingent upon: (1) the product being installed, maintained and operated in accordance with product literature and instructions, and (2) confirmation by Avdel of such defect, upon inspection and testing. Avdel makes the foregoing limited warranty for a period of twelve (12) months following Avdel's delivery of the product to the direct purchaser from Avdel. In the event of any breach of the foregoing warranty, the sole remedy shall be to return the defective Goods for replacement or refund for the purchase price at Avdel's option. [. . . ] Screw the Nose Tip into Nose Casing 1 and tighten with spanner*. Place Nose Casing 1 with `O' Ring 2 over Chuck Collet 9 and screw onto the tool, tightening with spanner* (None of the above parts are refitted). Screw Vacuum Shut-off `Stop Nut' 13 onto Head Piston 36. substitute Jaw Spreader Housing 1 with Chuck Collet Adaptor 07610-00501. Tighten fully onto piston before tightening the Stop Nut 13 against it. Fit Locking Ring 8 onto the Chuck Collet Adaptor. Lightly coat Jaws 4 with Moly Lithium grease. Locate Spring 7 onto the Spring Guide already in place. Drop the other Spring Guide 10 into Spring 7. Holding tool pointing down, screw the assembled Chuck Collet onto the Chuck Collet Adaptor and tighten with spanner. Screw Anvil Adaptor 71230-02063 into the Head Assembly. Place Anvil 12 over Chuck Collet 9 and lock into place with Anvil Nut 07610-00307. Nose assemblies should be serviced at weekly intervals. If the tool is in continuous use, the air hose should be disconnected from the main air supply and the tool lubricated every two to three hours. If there is no filter on the pressure regulator, bleed the air line to clear it of accumulated dirt or water before connecting the air hose to the tool. Check that the nose assembly or swivel head is correct for the fastener to be placed. check the stroke of the tool meets the minimum specification (page 5). The last step of the Priming Procedure on page 25 explains how to measure the stroke. Either a stem collector or a stem deflector must be fitted to the tool unless using a swivel head. check that Base Cover 31 is fully tightened onto Body 30. Stem Collector Bottle: `O' Rings 20 and 28 to be checked for wear, cleaned and lubricated with Molykote® 55m. Dismantle and clean the nose assembly with special attention to the jaws. [. . . ] position the slot in Piston 1 parallel to the step face in Housing 5. Slide Plate Shut Off 3 into the assembled parts 1, 2, 4, and 5. Retain parts in place using grease Molykote® 55. Place `O' Ring 4 into the recess of Cover Plate 6 retain in position using grease Molykote® 55. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AVDEL GENESIS NG4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AVDEL GENESIS NG4 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag