User manual BASETECH COST CONTROL 124400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BASETECH COST CONTROL 124400. We hope that this BASETECH COST CONTROL 124400 user guide will be useful to you.

Lastmanuals help download the user guide BASETECH COST CONTROL 124400.


Mode d'emploi BASETECH COST CONTROL 124400
Download
Manual abstract: user guide BASETECH COST CONTROL 124400

Detailed instructions for use are in the User's Guide.

[. . . ] Observe thc spccifications on the type plate ofthe appliance to be connected!Cost Control is only designed for use in dry rooms. Any other use, other than described, may lead to darnage of this product. Such usage mav res& in dan@ers of sbort circuitinn. [. . . ] Once this figure is known then it needs to be inputted inlo lhe unit. 3 . 6. If there arc any values inputed into it already that the User has not put in there themselves then they should be cleared. This is done by following Steps 7 and 8. 7. To Change the value in the "COST kWh" Screen, press the "SET" button once in any one of the other five scrcen displays i. e. `QAY, WEEK, MONTH. , YEAR or TOTAL COST" and the tost per kilowatt hour is displayed. To Change any preset values or to Set in new values, press the "+" button and the figure on the right band side will start flashing. To Change this figuxe from 0 to 9 ptess the "+" button. This will increase it by 1 with wery key press. If you accidentally go past the number you wished to Change then keep on ptessing the &+* button as the numbexs go from 0 to 9 and from 9 to 0 so that you tan set the required digit. To Change to the next digit press the "$IW' button. Repeat Steps 7 and 8 until the desired values per kWh arc inserted. If any of the figures do not require changing then simply press the "SKI" key to move to the next one. The previous screen (before Tti setting) will now be displayed showing the "TOTAL COST' as Zero. Plug the Cost Control into the mains supply and then plug the apphance you wish to monitor the tost of into the Cost Control and then. 11. The appliance should be operated as normal - for hints on this setz the «Extra Notes" section. After the desired time `has Iapsed and a readiig is rquired simply: a) Turn the appliance off. c) Remove the appliance Flom the Cost Control. If, however, further monitoring is required then do not remove the appliance from the Cost Control and the Cost Control fiom the mains socket but simply take the reading whilst they arc all still pluggcd into one another. 13. The readings cm be shown as either: a) Total tost of the actual dectricity used whilst the appliance was operating and plugged into the Cost Control. Example: The tost to operate appliance %?is 7. 00 per day and after 20 days of operating the appliance, the TOTAL COST is, b) `Total tost per day, c) Total tost per week, d) TotaI tost per month, e) Total tost per year, (The example pictures shown assume a daily value of 7. 00 and 7 days per week, 30 days a month and 365 days a year) To altemate between these displays simply press the "DISPLAY" key. As the price of the kWh unit does not Change then the total tost display (actual used, dsy, week, month and year) on. ly requires resetting. [. . . ] Example 2: Same appliances are turned on and off for varying amounts of time constantly, exampfes of which an refrigerators, freezers etc, AS the power they ustz varies because of the time the motor is on and off then it is recommended to keep the appliance plugged into the Cost Control for several days before taking the reading. If a reading is taken after it has turned on and off onIy once then this will not be an accurate reading of its tost OW time. It will only be an accurate readii of the tost of power that it has used in total. Example 3: Some appliances are used Xrequently, examples could be power tools such as drihs, kitchen appliances such as food mixers and so on. In cases liie this it is not xecommended to try to work out the average tost per day, week, month or year. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BASETECH COST CONTROL 124400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BASETECH COST CONTROL 124400 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag