User manual BAUER KAP DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BAUER KAP. We hope that this BAUER KAP user guide will be useful to you.

Lastmanuals help download the user guide BAUER KAP.


Mode d'emploi BAUER KAP
Download
Manual abstract: user guide BAUER KAPDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Otherwise technically identical to the standard VERTICUS range, the F-unit range offers a particularly good price-performance ratio thanks to the use of a conventional star-delta control. KOMPRESSOREN KAP-H-Range Horizontal design for operation on heavy seas and extreme inclinations The low centre of gravity and the block design allow the operation even on heavy seas. Scope of supply similar to KAP-range, however, with P 41 DUO filter system and without filling devices. KAP-DAH - Range Diesel driven unit for self-sufficient use in remote areas Robust and low-maintenance diesel motor, particularly unsusceptible at high temperatures. Same fuel with mobile use on diesel driven trucks and pick-ups. KAP-23 / 220 - Range Unlimited performance for high-damage incidents The performance of the stationary KAP-range can meet every requirement. [. . . ] In the BAUER Testing- and Research Centre the composition for the respective application is calculated, optimized and extensively tested. Replacement cartridges from uncontrolled sources threaten your health not only creating poor filter performance and icing of the breathing regulator, but also producing corrosion, which will rapidly ruin the equipment. Those, who buy cheap, buy expensive!To achieve a germfree and unsaturated condition, a filter cartridge can only be filled under industrial production conditions. The balance of carbon and molecular sieve of BAUER original cartridges is adjusted perfectly. Mechanical filling guarantees exact dosing and piling to create the perfect crossflow of the cartridge for optimum air purification. After filling the cartridges are vaccuumized and the density is checked. Final separator assembly at BAUER Production- and material numbers guarantee a perfect production control Your life is at risk with fake cartridges! EATHIN BR G PURE A IR Only original cartridges made by BAUER guarantee that oil, humidity or hydrocarbons in the compressed air are completely removed. The limiting values of BAUER filter systems comply with and exceed all major national and international standards such as DIN EN 12021 and medical air acc. to European KOMPRESSOREN R YO F UR SA The quality seal of an original BAUER cartridge stands for purest breathing air T E Y 7 FO KOMPRESSOREN 1 The compressed air 2 The condensate The condensate from the oiland water droplets is collected at the bottom of the filter housing and is removed via the condensate drain valve. 3 The pre-purified air flows from the bottom of the vessel through the molecular sieve, which adsorbs the remaining gaseous water. The pores of the granules are minute in diameter in order to provide continuous filtration and total removal of the water molecules. The molecular sieve used by BAUER matches perfectly the granule and pore size for the filter system. This is the only way to comply with the strict limiting values of breathing air norms. 4 Particle filter from the compressor block is delivered to the final separator. The separator effectively separates oil- and water droplets. holds all impurities and particles. 5 An activated carbon layer for breathing air applications removes all organic impurities such as oil vapour and hydrocarbons. 5 1 6 Purest air or gas leave the filter cartridge and are ready for the application. 4 3 7 The pressure maintaining valve 6 2 keeps the filter housing continuously under pressure to increase the partial pressure on the molecular sieve. So the speed of the flow through the cartridge is reduced, which increases the purification effect even more. Load cycles are reduced, too - a positive effect on the lifetime of the filter housings and the operating safety. S E C U R U S F I LT E R M O N I T O R I N G T H E B O D Y G U A R D O F Y O U R F I LT E R S Y S T E M SECURUS protects against damage: All filter cartridges have a limited life, which must be monitored. The patented SECURUS system takes away from you the important but annoying responsibility of monitoring the cartridge for the necessary timely replacement. With SECURUS it is impossible to overuse the filter, which would damage the following system with oil and water. [. . . ] 2 x PN 200 connections + 2 x PN 300 connections with switch over 2 x PN 200 connections + 2 x PN 300 connections with pressure reducer Other equipment and versions on request!Optional: B-CONTROL Operating panel for remote compressor control. Switch-over device The air overflows directly from the storage bank into the high pressure tanks. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BAUER KAP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BAUER KAP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag