User manual BAUKNECHT WED97HEX DIMENSIONS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BAUKNECHT WED97HEX. We hope that this BAUKNECHT WED97HEX user guide will be useful to you.

Lastmanuals help download the user guide BAUKNECHT WED97HEX.


Mode d'emploi BAUKNECHT WED97HEX
Download
Manual abstract: user guide BAUKNECHT WED97HEXDIMENSIONS

Detailed instructions for use are in the User's Guide.

[. . . ] Electric Dryer Installation Instructions PRODUCT MODEL NUMBERS WED94HEX, WED95HEX, WED97HEX, WEDXXHEX Electrical: This dryer requires a 3 or 4 wire, single phase, 120/240 volt, 60 Hz. , AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. [. . . ] Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See "Venting Requirements. " 3/4"* (18 mm) OVERALL DIMENSIONS Dryer dimensions Front view: 27" (686 mm) Side view: 507/8" (1292 mm) 305/8" (728 mm) 381/8" (968 mm) Left or right side exhaust 3 /4"* (18 mm) Back view: 61/2" (165 mm) 297/8"* (759 mm) 31/2"* (89 mm) A B A. Angled hood (acceptable) C 61/8"* (156 mm) (365 mm) 143/8" 3 /4"* (18 mm) * Approximate measurement The Vent system chart provides venting requirements that will help achieve best drying performance. NOTE: Side and bottom exhaust installation have a 90° turn inside the dryer. To determine maximum exhaust length, add a 90° turn to the total number of elbows when referemcing the chart. Closet installation (dryer only): Vent system chart Number of 90° elbows Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered hoods 64 ft. (6. 4 m) 5" (127 mm) 18" min. (457 mm) 3" (76 mm) 48 in. 2 min. (310 cm2) 0 1 2 3 4 3" (76 mm) 1" (25 mm) 24 in. (155 cm2) 2 For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. [. . . ] For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BAUKNECHT WED97HEX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BAUKNECHT WED97HEX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag