User manual BEHRINGER EUROLIGHT LD6230

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BEHRINGER EUROLIGHT LD6230. We hope that this BEHRINGER EUROLIGHT LD6230 user guide will be useful to you.

Lastmanuals help download the user guide BEHRINGER EUROLIGHT LD6230.


Mode d'emploi BEHRINGER EUROLIGHT LD6230
Download
Manual abstract: user guide BEHRINGER EUROLIGHT LD6230

Detailed instructions for use are in the User's Guide.

[. . . ] A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10) Protect the power cord from being walked on or pinched particularly at plugs, extension cords, and the point at which they exit the unit. [. . . ] Please assure that your EUROLIGHT is sufficiently cooled and that it is not placed near heat sources that could cause overheating. If you want to run your EUROLIGHT on mains voltage other than factory-specified voltage, contact the nearest BEHRINGER service center. To effectively limit harmonic currents and avoid voltage fluctuations that could affect other electrical appliances, connect this equipment to an AC outlet that complies with all applicable technical standards. In all other cases, contact your local power supply provider for advice prior to usage. Defective fuses must be replaced with fuses with identical rating! The LD6230 is a Class I device in which a low-Ohm protective ground wire is an integral part of its safety design. During the installation, make sure that a low-Ohm protective conductor (< 0, 1 Ohm) exists between all bare metal parts and the grounding on the main connector. Quhr L1 L2 L3 Ppuhry 8C CH 2 8C" X X X CH 4 X 8C$ CH 6 + + X X * Activation of control electronics and respective output channel CONNECTOR TERMINAL STRIP The connector terminal strip of your LD6230 is laid out for cables with diameters between 0. 326 mm 2 (AWG 22) and 4 mm2 (AWG 12). When using flexible access lines, cable end contacts corresponding to manufacturer specifications have to be used. To assure good contact, skin the cable endings between 9 - 13 mm. During the installation, all applicable national standards need to be adhered to. + + + MAINS/ILLUMINANT CONNECTORS To facilitate additional flexibility, your dimmer pack has a connector terminal strip. Cable bushings for connecting to the mains and your illuminants are located in the back. Flexibility is further enhanced with the option to retrofit a CEE connector and a 16-pin HARTING connector. Both fixed and mobile installations require compliance with IEC 61010-1:2001 (EN 6110-1:2001). In particular, a 3-phase separator (pursuant IEC60947-1 and IEC60947-3) needs to be included in the installation. This separator needs to be labeled according to IEC 60417-50008 and IEC 0417-5007. To assure compliance with Directive 89/336/EEC, only use specified upstream line filters with your EUROLIGHT. Using it without line filters specified by BEHRINGER may lead to electromagnetic interference. More detailed information on this subject can be found at www. behringer. com. Illustration: LD6230 connector terminal strip When your LD6230 leaves the assembly plant, all incoming and outgoing neutral conductor connectors are bridged. The incoming phases L1/L1, L2/L2 and L3/L3 are always connected to one another in pairs and switched to the overload protection of the channels 1 to 6. They protect output connectors E1 to E6 . Each of the channels can handle currents of maximum 10 Amperes. The green-yellow conductors (PE) may only be used as protective conductors. 3 INSTALLATION INSTRUCTIONS EUROLIGHT LD6230 The lowest cable gauge between L1 and L3, incoming neutral conductor (N) and protective earth (PE) is 4 mm 2 (AWG 12). For outgoing channels E1 to E6, use cables with gauges corresponding to the loads used (2. 5 mm2 (AWG 14) or 1. 5 mm2 (AWG 16)). Phrrb6d 6 - 10 13 - 16 18 - 25 Ivhyp 6XB rpvbd@V VT6 1. 5 2. 5 4 16 14 12 + + + During the installation, please adhere to all manufacturer instructions. Regardless from mains supply voltage, the maximum output current of the EUROLIGHT LD6230 is 10 A per dimmer circle. [. . . ] Their use neither constitutes a claim of the trademarks by BEHRINGER nor affiliation of the trademark owners with BEHRINGER. BEHRINGER accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph or statement contained herein. Colours and specification may vary slightly from product. Products are sold through our authorised dealers only. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BEHRINGER EUROLIGHT LD6230

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BEHRINGER EUROLIGHT LD6230 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag