User manual BENSHAW RSM SEP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BENSHAW RSM SEP. We hope that this BENSHAW RSM SEP user guide will be useful to you.

Lastmanuals help download the user guide BENSHAW RSM SEP.


Mode d'emploi BENSHAW RSM SEP
Download
Manual abstract: user guide BENSHAW RSM SEP

Detailed instructions for use are in the User's Guide.

[. . . ] RediStart Micro Synchronous Excitation Package The Leader in Solid State Motor Control Technology Publication # : 890000-20-01 Blank Page REDISTART MICRO SEP INSTRUCTION MANUAL 1. DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 1 STANDARD FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 2 SYNCHRONOUS EXCITATION PACKAGE FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 3 REDISTARTTM MICRO POWER CARD LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] This parameter sets the low trip point for the measured line power factor. If the line power factor falls below this set level during motor operation, then the controller will shut down and a fault will be registered. This parameter sets the high trip point for the measured line power factor. If the line power factor rises above this set level during motor operation, then the controller will shut down and a fault will be registered. Back Spin Timer Low PF Trip High PF Trip MENU 4: I/O & DISPLAY Meter #1 and #2 display These meters may be programmed to display one of the following: Asc Aav A1, 2, 3 Vsc Vav V1 Hz O/L pf etm W1 WH1 Var1 fldA Slip 1 (scrolls through the three stator currents) (the average of the three stator currents) (stator current on line 1, 2, 3) (scrolls through the three line voltages) (the average of the three line voltages) (voltage on line 1, 2, 3) (line frequency) (motor thermal content) (line power factor) (elapsed running time meter) (Watts) (Watt Hours) (reactive power) (field current) (percent slip speed) Auto ranges between Watts, Kilo-Watts and Mega-Watts. 17 REDISTART MICRO SEP INSTRUCTION MANUAL Relay #1 and #2 Output These relays may be programmed to indicate one of the following conditions: OL OLL OLW RUN UTS SHT GDF SPT UCT PFH PFL FCT FS12 FS2 FCX2 (Overload Trip) (Overload Lockout) (Overload Warning) (Run) (Motor Up-To-Speed) (Shunt Trip) (Ground Fault) (Shear Pin Trip) (Under Current Trip) (High Power Factor Trip) (Low Power Factor Trip) (Field Current Trip) (Field Applied) (Field Discharge Resister Control) (Field Control) The OLW contact can be used to drive a motor unloader, the RUN contact can be used to sequence an inline contactor, and the UTS contact can be used to sequence a bypass contactor. The SHT contact will change state on various fault scenarios. If the automatic fault reset jumper (JPC19) is not in, this relay will change state on any fault. If the automatic fault reset jumper is in, this relay will change state on any critical fault, or on the occurrence of the fourth non-critical fault in one hour. This relay output option is intended to be used for shunt tripping a circuit breaker, or interlocking with two wire start/stop control. Opt Relay #1 Out Opt Relay #2 Out Opt Relay #3 Out This relay is programmed as FS1. Refer to Relay #1 and #2 Outputs. MENU 5: EVENT RECORDER Event Recorder Displays 1-99 most recent events. See section 7. 3 and section 8 for description and listing of codes and conditions. 2 A delay may be programmed for this relay. See Menu 9. 18 REDISTART MICRO SEP INSTRUCTION MANUAL MENU 6: PASSWORD PROTECTION Password Protect The RediStartTM Micro is supplied with a passcode protection feature. When this feature has been enabled, most programmable menu parameters can only be viewed and not changed. The only parameters which can be altered when the passcode is enabled are the Meter #1 & 2 Display parameters. The RediStartTM Micro will arrive with the passcode feature disabled. This is indicated by a passcode value of 000 appearing under the password menu. If passcode protection is desirable, the user may select a three digit passcode from 001 to 999 (excluding 500). This value is entered just like any other parameter. When the passcode is chosen and entered, the controller will be in data entry enable mode. In order to lock out data entry, the user must set the passcode to any other value or press the micro reset button (SW2). This will lock out data entry and indicate passcode protect mode with a small dot (. ) in the bottom center of the display. To re-enable data entry, simply re-enter the passcode. [. . . ] Voltage transient protector Current transformers 1-60 Amp controllers (see schematic) Current transformers 20-180 Amp controllers (see schematic) Current transformers 40-500 Amp controllers (see schematic) Current transformers 70-1200Amp controllers (see schematic) QUANTITY 1 1 1 1 1 3 3 3 BICT26401 3 BICT57601 3 29 REDISTART MICRO SEP INSTRUCTION MANUAL 9. JUMPER LISTING AND SETTINGS JUMPER LISTING AND SETTINGS CHART 1 CPU CARD JUMPER JPC3 JPC5 JPC7 JPC10 JPC11 JPC12 JPC13 JPC15 JPC16 JPC17 JPC19 JPC22 JPC23 DESCRIPTION DECEL\BRAKING LCD START BUTTON O/L RESET AUTO/MANUAL PWM POWER PWM OUTPUT GATE FIRING LCD STOP BUTTON EPROM SIZE COMM SELECT EQUIP INTEGRAL BYPASS FAULT RESET AUTO/MANUAL RS-485 COMM SERIAL COMM POSITION IN (1-2) DISABLE ENABLE AUTO +5V PWM PULSE ENABLE 27C256 RS-232 YES AUTO ENABLE DISABLE POSITION OUT (2-3) ENABLE DISABLE MANUAL +12V PLD BLOCK DISABLE 27C512 RS-485 NO MANUAL DISABLE ENABLE POWER CARD JUMPER JPP2 JPP3 JPP4 DESCRIPTION LINE SYNCHING LINE SYNCHING LINE SYNCHING CHART 2 POSITION IN (1-2) L-L L-L L-L POSITION OUT (2-3) L-N L-N L-N CHART 3 POWER CARD SWITCH SW1 - CT BURDEN POSITION 1 2 18. 7 OFF OFF 7. 5 ON OFF 3 ON ON 30 REDISTART MICRO SEP INSTRUCTION MANUAL 10. PARAMETER VALUES The following table lists all of the default parameters for the software. If the battery ram is reset, all parameters will revert to these default values. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW RSM SEP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW RSM SEP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag