User manual BENSHAW SMVRSM1218

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BENSHAW SMVRSM1218. We hope that this BENSHAW SMVRSM1218 user guide will be useful to you.

Lastmanuals help download the user guide BENSHAW SMVRSM1218.


Mode d'emploi BENSHAW SMVRSM1218
Download
Manual abstract: user guide BENSHAW SMVRSM1218

Detailed instructions for use are in the User's Guide.

[. . . ] Publication #: 890015-05-03 REDISTART MICRO II SYNCHRONOUS STARTER W/ SOLID STATE FIELD SUPPLY SMVRSM12/18 SERIES 1, 500 to 7, 200 V W/ Advanced Fiber Optic Technology The Leader In Solid State Motor Control Technology April 2006 Software Version: 810010-04-20 © 2006 Benshaw Inc. retains the right to change specifications and illustrations in text, without prior notification. The contents of this document may not be copied without the explicit permission of Benshaw, Inc. Congratulations on the purchase of your new Benshaw Micro II SMVRSM Soft Starter. Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. [. . . ] This time is the delay before a fault will occur. The bypass time is adjustable from 1 to 10 seconds in 1 second intervals. The default value for the bypass parameter is 4 seconds. Values Default Trip Input Description The trip input parameter sets the time that power must be removed from the 120VAC input at JC13 terminal #1 on the RediStart Micro II CPU card before a fault occurs. When an external fault occurs, the starter will shut down and display a Fault 75: External Fault. The trip input parameter can be set from 0. 1 to 90. 0 seconds in 0. 1 second intervals. The default value for the trip input parameter is 0. 5 seconds. Values Default 69 5. 22 MOTOR PROTECTION - MISC. Phase Orde (phase order) Description The line phasing parameter sets the phase sensitivity of the starter. This can be used to protect the motor from a possible change in the incoming phase sequence. If the incoming phase sequence does not match the set phase rotation, the starter will display ph err while stopped and will fault if a start is attempted. Fault Code 1 or 2 - Not ABC or Not CBA will be displayed when this condition occurs. Values The line phasing can be set to; - will run with either phase sequence · INS · ABC - will only run with ABC phase sequence · CBA - will only run with CBA phase sequence Default The default value for the phase sensitivity parameter is INS. # Auto RST (number of auto resets) Description The number of auto resets parameter sets how many times in one hour the RediStart Micro II will reset a non-critical fault. This parameter is used in conjunction with the automatic fault reset jumper JPC19 (see page 22) and with the fault classes sub-menu (see page 71). When JPC19 is placed in the automatic fault reset position (1-2), this parameter sets how many times in one hour any non-critical faults are reset before a manual reset is required. Non-critical faults are set in the fault classes sub-menu (see page 71). z NOTE: Consult motor manufacturer for the specified starts/hour. Values Default The number of auto resets parameter can be set from 1 to 5. The default value for the number of auto resets parameter is 4. No Main PW (no main power) Description The no mains power delay parameter sets the period of time that the starter must have a run command without mains power before a no mains fault will occur. If line power is not applied, the starter will display No Line in the bottom left of the LCD. Fault Code 98 - No Mains Power will be displayed when a start is commanded and the delay is exceeded. Values Default The no mains power delay parameter is adjustable from 1 to 5 seconds in 1 second intervals. The default value for the no mains power parameter is 1 second. 70 5. 23 MOTOR PROTECTION - FAULT CLASSES Fault Classes Description The fault classes menu allows the user to change the action taken when a fault occurs. The menu will allow every fault to be given a different classification depending on the user requirements. This allows the user to set the starter to; · Trip the starter and display the fault code and description if it occurs. [. . . ] DANGER: Equipment may be damaged or personal injury may result if equipment is started with lightning arrestors, power factor capacitors or surge capacitors connected on the load side of the solid-state motor controls. STARTUP PROCEDURES (All procedures are found in your instruction manual): Pre-startup procedures followed Connection procedures followed Proper cable size All Connections tight (Power & Control) Name of person completing this report: Signature: WARRANTY STATUS (For Benshaw Office Use Only): Date Shipped: Comments: Effective Date: Expiration Date: Approved by: Startup procedures followed Please return to your nearest Benshaw distributer: Benshaw Inc. , 1659 E. Sutter Road, Glenshaw, PA, 15116, Attn: Warranty Department, Fax: 412-487-4201 Benshaw Canada, 550 Bright Street E, Listowel, Ontario, Canada N4W 3W3, Attn: Warranty Department, Fax: 519-291-2595 ********** Complete the warranty registration on-line at http://www. benshaw. com ********** WN0001-02 - 3 Year Warranty Data Sheet - Revision July 05. doc Page 1 of 1 176 11. 1 3-Year Warranty Warranty Notes WN0001-02 3-YEAR WARRANTY DATA SHEET General Conditions All warranties are provided in accordance with Benshaw, Inc. Benshaw warrants its' products including printed circuit boards, power electronic assemblies and integral bypass contactors per the periods and warranty types listed below. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW SMVRSM1218

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW SMVRSM1218 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag