User manual BENSHAW SURPROTEX SPD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BENSHAW SURPROTEX SPD. We hope that this BENSHAW SURPROTEX SPD user guide will be useful to you.

Lastmanuals help download the user guide BENSHAW SURPROTEX SPD.


Mode d'emploi BENSHAW SURPROTEX SPD
Download
Manual abstract: user guide BENSHAW SURPROTEX SPD

Detailed instructions for use are in the User's Guide.

[. . . ] Tunnel Access: 1 Carefully remove 1 of the 2 finger guards which cover the screw terminals by pusing up on the front edge of the guard. 3 Gently pull the bus cover assembly apart. 4 Extract the bus bars from the opposite side of the relay. 5 Run each phase of the load power wire through the corresponding "tunnel". Display Mounting: The display unit may be mounted on top of the SPD relay, or mounted on the exterior of a control panel with the optional panel mounting kits (SPD-M1~4). [. . . ] The SPD-60XX-X must have this parameter set at 10. Values: 1, 5-120 in steps of 5 Default: The default value is 1 for SPD-06XX-X and 10 for SPD-60XX-X 9. P-F: Description: This parameter activates the Phase Failure detection for the SPD. If current is lost in one or two phases for more than 3 seconds the SPD will trip. Off/On Values: The default value for this parameter is On Default: Time Dial: Description: This dial sets the overload class of the SPD. The SPD uses an I^2T curve that, at 600%, will trip in the time set by this dial. 0-63 in steps of 1 Values: The default value is 0 Default: Terminals: Description: A1-A2: 120 VAC 60 Hz control power 95-96: N/C Trip contact (Opens at 100% thermal capacity) 97-98: N/O Trip contact (Closes at 100% thermal capacity) 07-08: SPD-XXS-X:N/O Alarm contact (Changes state at Alt% setting) SPD-XXSZ-X: Zero sequence CT input DISCONNECT DEVICE AC120V TR OFF (RESET) MC X1 X2 AC120V MC FUSE FUSE TR OFF (RESET) MC ON OL GF RUN STOP TRIP TRIP 2. dEF: A1 A2 95 97 07 AX1 MC ON SPD OL GR AX2 96 98 08 MC GROUND FAULT CT Description: This parameter sets the length of time the SPD will ignore current flow after a start is given if parameter 1 is set to dEF. If parameter 1 is set to Inv, this parameter is not accessible. Values: 00-30 seconds in 2 second steps The default value is 00 seconds Default: A1 96 97 98 07 08 A2 95 97 07 Parameter Descriptions: AL 3. r. P: Description: This parameter activates Reverse Phase detection. When it is activated the SPD must see ABC rotation to allow a start. When deactivated, the SPD is insensitive to phase rotation. Off/On Values: The default value is Off Default: 6. StL: Description: This parameter activates the Stalled Motor detection. When activated and the load draws 180% of the Current Dial setting for 5 seconds after a start, the SPD will trip. Values: Off/On Default: The default value for this parameter is Off SPD 96 98 08 2 NO - Closes on all faults except control power failure 1 NC - Opens on all faults (open when no control power applied) Current Dial: Description: This dial sets the Full Load Amps (FLA) for the SPD. This dial should be set at (Motor FLA x Motor Service factor)/CT ratio. This value is used for all of the SPD's current based functions. Values: 0. 5-6. 3 Amps in 0. 1 Amp steps for SPD-06XX-X, 5. 0-63 Amps in 1 Amp steps for SPD-60XX-X Default: The default value is 0. 5 for SPD-06XX-X, and 5. 0 for SPD-60XX-X Sto: Description: This must be selected to save changes to parameter, otherwise changes will be aborted when TEST mode is exited. Und: Description: This parameter sets the Undercurrent protection for the SPD. If the load current falls below this level for 3 seconds, the SPD will trip. [. . . ] Values: 1, 5-120 in steps of 5 Default: The default value is 1 for SPD-06XX-X and 10 for SPD-60XX-X 9. P-F: Description: This parameter activates the Phase Failure detection for the SPD. If current is lost in one or two phases for more than 3 seconds the SPD will trip. Values: Off/On The default value for this parameter is On Default: Time Dial: Description: This dial sets the overload class of the SPD. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW SURPROTEX SPD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW SURPROTEX SPD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag