User manual BERTAZZONI C36500X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BERTAZZONI C36500X. We hope that this BERTAZZONI C36500X user guide will be useful to you.

Lastmanuals help download the user guide BERTAZZONI C36500X.


Mode d'emploi BERTAZZONI C36500X
Download
Manual abstract: user guide BERTAZZONI C36500X

Detailed instructions for use are in the User's Guide.

[. . . ] Installation, Service and User Instructions Built-in gas cooktops BERTAZZONI DIMENSIONS: 36'' (915 mm)(W) x 253/16'' (640 mm)(D) Models C36500X (Z36500X) Models C36600X (Z36600X) IMPORTANT - PLEASE READ AND FOLLOW [C3W0. . U4X(2 or 5)A] [C3Y0. . U4X(2 or 5)A] -Before beginning installation, please read these instructions completely and carefully. -Do not remove permanently affixed labels, warnings, or plates from the product. -Please observe all local and national codes and ordinances. -Please ensure that this product is properly grounded. [. . . ] Do not cut or remove the grounding prong from this plug. WARNING ELECTRICAL SHOCK HAZARD · Disconnect electrical power at the circuit breaker box or fuse before installing the appliance · Electrically ground appliance · Use copper conductors only. Failure to follow these instructions could result in seriuos injury or death 5 Wiring diagram For freestanding gas range model C36600X (Z36 6 00 X) C3Y0. . U4X(2 or 5)A CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. For freestanding gas range model C36500X (Z36 5 00 X) CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. C3W0. . U4X(2 or 5)A 6 GAS CONNECTION All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. This range uses a 1/2" NPT (see fig. in this chapter for details of gas connections installations) inlet. Sealant on ali pipe joints must be resistive to LP gas. Manual Shut-off Valve: This installer-supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and in a position where it can be reached quickly in the event of an emergency. The manual shut-off valve shall be installed properly in order to be accessible when appliance is installed in definitive position. In Massachusetts: A 'T' handle type manual gas valve must be installed in the gas supply line to this appliance. in this chapter) a) All cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation, since service pressure may fluctuate with local demand. The pressure regulator is supplied separately with the appliance; regulator has two female threads ½" NPT; it shall be installed properly in order to be accessible when appliance is installed in definitive position. b) Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company. Please provide the service person with this manual before work is started on the range. (Gas conversions are the responsibility of the dealer or end user. ) c) This range can be used with Natural or LP/Propane gas. It is shipped from the factory adjusted for use with natural gas. d) Manifold pressure should be checked with a manometer, natural gas requires 4. 0" W. c. P. and LP/Propane requires 11. 0" W. C. P. Incoming line pressure upstream from the regulator must be 1" W. c. P. [. . . ] If the burner does not remain alight after releasing the knob repeat the above procedure, Note: It is recommended not to try to ignite the burner if the relative flame cap is not in the correct position Note: Dual burner is composed by two burner (inside and outside); each one operates under the relative gas valve indipendently from the other one. Tips for using burners correctly: WARNING: During use of each gas burner(s) adjust the burner flame size properly so it does not extend beyond the edge of the cooking utensil. This is an instruction based on safety considerations - Use suitable pots for each burner (see Fig. and Table ) - When the liquid is boiling, turn down the knob to the MINIMUM position. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BERTAZZONI C36500X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BERTAZZONI C36500X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag