User manual BERTAZZONI MODELS B3W0..U4X(2 OR 5)D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BERTAZZONI MODELS B3W0..U4X(2 OR 5)D. We hope that this BERTAZZONI MODELS B3W0..U4X(2 OR 5)D user guide will be useful to you.

Lastmanuals help download the user guide BERTAZZONI MODELS B3W0..U4X(2 OR 5)D.


Mode d'emploi BERTAZZONI MODELS B3W0..U4X(2 OR 5)D
Download
Manual abstract: user guide BERTAZZONI MODELS B3W0..U4X(2 OR 5)D

Detailed instructions for use are in the User's Guide.

[. . . ] WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS - Do not try to light any appliance. - Do not use any phone in your building. [. . . ] Trim the part of the sealing strips which extend beyond the hotplate base Before connecting the appliance to the gas supply, first remove the plastic plug on which is pressfitted into the gas inlet union; to remove, just pull it off. This appliance shall be installed in accordance with installation requirements of the local gas authority of the appropriate installation code. Before installing the hotplate consider the location of the gas supply and routing the gas line. After installing the gas supply and making all connections check thoroughly for possible leaks. Turn all control knobs on the unit to `OFF' position. Using a soap and water solution check each gas connection one at the time, by brushing the solution over the connection. If it is not possible to correct the leak, replace fitting. under no circumstances use matches or flame for checking leaks. It is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage 7. To checking inlet pressure at the appliance operate as follow: a) Disconnect electric power before pressure checking be carried out. B) Take off one of the gas burner cap and the relative flame spreader in order to get access to the burner injector. C) Put in position the pressure detector directly on the burner injector afterward open the relative burner knob at maximum position keeping it pressed, then measure the outlet pressure from the burner injector. D) Once the pressure checking has been carried out, replace the burner cap and flame spreader in the correct and original position and re-connect electric power to the appliance. Turn on appliance control cock and light each burner. Check for a clear blue flame without yellow tipping. If burners show any abnormalities check that they are located properly and in line with the injector nipple. Sometimes the burners will not ignite immediately and seem to `blow' slightly when they do ignite. This usually due to air in the gas lines, which will clear itself within seconds. If after following the instructions given, satisfactory performance cannot be obtained, contact the local gas authority for advice and assistance. Electric power absorption is about 1W for 5 gas burner version or 2W for 6 gas burners version. WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong) grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptable. Do not cut or remove the grounding prong from this plug. [. . . ] Extract and clean the seal cone and its housing with a rag soaked with thinners. Lightly grease the cone with a special grease. Insert the cone, moving it several times, remove it again, remove the excess grease and make sure that the gas passage ways are unobstructed. Replace all the pieces in reverse order and check that the valve operates correctly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BERTAZZONI MODELS B3W0..U4X(2 OR 5)D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BERTAZZONI MODELS B3W0..U4X(2 OR 5)D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag