User manual BIAMP SEQ 301 M2-V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP SEQ 301 M2-V. We hope that this BIAMP SEQ 301 M2-V user guide will be useful to you.

Lastmanuals help download the user guide BIAMP SEQ 301 M2-V.


Mode d'emploi BIAMP SEQ 301 M2-V
Download
Manual abstract: user guide BIAMP SEQ 301 M2-V

Detailed instructions for use are in the User's Guide.

[. . . ] It is factory configured with one DSP card and is capable of handling up to two additional DSP cards. [. . . ] It is factory configured with one DSP card and is capable of handling up to two additional DSP cards. The SERVER-IO can be configured with one 420 x 420 channel AVB card or one AVB card and one or two 32 x 32 channel SCM CobraNet® cards. An integral network card provides redundant network connection for configuration setup and control of the Tesira network. The server shall also supportuseofoneortwo32x32channelCobraNetdigitalnetworkingcards. Theservershallbeconfiguredwithat leastoneDSPcardandshallbecapableofsupportingatotalofthreecards. TheservershallprovidedualEthernet portsforredundantconfigurationandcontrolconnection. Theservershallbeconfigurableforupto48channelsof localaudioinputandoutput, includingmicandlinelevel, VoIP, andtelephoneinterface. Theservershallalsosupport modular I/O cards for acoustic echo cancellation and ambient noise compensation. The server shall provide front panelLEDidentificationofserverpower, status, alarm, andactivityaswellassystem-widealarm. Theservershall providefrontpanelLCDdisplayforserverandsysteminformation. Theservershallberackmountable(3RU)and featuresoftware-configurablesignalprocessing, includingbutnotlimitedto:signalroutingandmixing, equalization, filtering, dynamics, anddelay, aswellascontrol, monitoring, anddiagnostictools. TheservershallbeCEmarked, ULlistedandshallbecompliantwiththeRoHSdirective. Warrantyshallbefiveyears. TheservershallbeaTesira SERVER-IO. SERVER-IO SPECIFICATIONS (audio specifications given reflect use of SIC-4 and SOC-4) Frequency Response (20Hz~20kHz @ +4dBu): THD+N (20Hz~20kHz): @ 0dB Gain, +4dBu In @ 54dB Gain, -50dBu In EIN (20Hz~20kHz, 66dB Gain, 150 ohm): Dynamic Range (20Hz~20kHz, 0dB): Input Impedance (balanced): Output Impedance (balanced): Cross Talk (channel to channel @ 1kHz): @ 0dB Gain, +4dBu In @ 54dB Gain, -50dBu In Maximum Input: Maximum Output: +0/-0. 25dB Phantom Power: Input Gain Range (6dBs): Sampling Rate: A/D ­ D/A Converters Power Consumption (100~240VAC 50/60Hz): Overall Dimensions: Height: Width: Depth: Weight: Compliance: +48 VDC (7mA/input) 0 - 66dB < 0. 006% < 0. 040% < -125dBu > 108dB 8k ohm 200 ohm 48kHz 24-bit < 150W < 85dB < 75dB +24dBu +24dBu 5. 25 inches (133 mm) 19. 0 inches (483 mm) 17 inches (432 mm) 18 lbs (8. 2 kg) FCC Part 15B (USA) FCC Part 68 (USA) Industry Canada CS-03 (Canada) CE marked (Europe) UL and C-UL listed (USA & Canada) A-Tick (Australia) C-Tick (Australia) RoHS Directive (Europe) SERVER-IO BACK PANEL BIAMP SYSTEMS assembled in the USA www. biamp. com SERVER-IO 14 Logic I/O +5V 4 3 2 1 13 12 11 10 9 8 7 6 5 4 3 2 1 SNC-1 Primary 100 - 240V~ 50/60Hz 550W S/N Secondary Serial 1 Serial 2 52SJ N24138 N24138 10 US: 6RMBR00B - STC-2, Complies with FCC Part 68 IC: 3184A - STC-2 BLACK connectors = OUTPUTS BLUE connectors = ANC INPUTS ORANGE connectors = AEC INPUTS GREEN connectors = INPUTS BiampSystems, 9300S. W. GeminiDrive, Beaverton, Oregon97008U. S. A. (503)641-7287www. biamp. com 15June11 [. . . ] The server shall also supportuseofoneortwo32x32channelCobraNetdigitalnetworkingcards. Theservershallbeconfiguredwithat leastoneDSPcardandshallbecapableofsupportingatotalofthreecards. TheservershallprovidedualEthernet portsforredundantconfigurationandcontrolconnection. Theservershallbeconfigurableforupto48channelsof localaudioinputandoutput, includingmicandlinelevel, VoIP, andtelephoneinterface. Theservershallalsosupport modular I/O cards for acoustic echo cancellation and ambient noise compensation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP SEQ 301 M2-V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP SEQ 301 M2-V will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag