User manual BIAMP T-SERIES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP T-SERIES. We hope that this BIAMP T-SERIES user guide will be useful to you.

Lastmanuals help download the user guide BIAMP T-SERIES.


Mode d'emploi BIAMP T-SERIES
Download
Manual abstract: user guide BIAMP T-SERIES

Detailed instructions for use are in the User's Guide.

[. . . ] 5) Do not use this apparatus near water. 7) Do not block any ventilation openings. Install product in accordance with the manufacturer's instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. [. . . ] This connection allows dual 24V DC power inputs to be used. Dual 24V DC supply capability allows the amplifier to meet standards that call for redundant power supplies. The DC supply must be wired into both power supply inputs, either from redundant supplies or from a single supply wired in parallel to the two inputs. If 24V is not supplied to both inputs, a loss-ofsupply fault will be reported. If a VA-4030e or VA-2060e amplifier is required to operate without a 24V supply, the Auxiliary supply fault monitoring must be disabled in Vocia software. A loss of supply fault is indicated via the Vocia software and by a blinking yellow Amp Fault indicator on the front panel of the affected device. The power supplies used for the amplifier must meet the voltage range and power requirements detailed in the specifications table below. Local standards, norms or codes may require the use of certified power supplies and may require observance of minimum on-battery running times both for standby and maximum power conditions. Note that dual redundant power supplies must each independently meet the total power requirements of the amplifier. The pluggable terminal blocks provided will accommodate wire sizes from 12-18 AWG. External over-current protection must be provided, according to the current carrying capacity of the connecting wires, and in no case greater than 30 Amps. Input sensitivity and 48V phantom power on/off state may be determined in the Vocia software. Because a local input may only be delivered to the channel associated with that input, if a local background source is required on two or more channels the source must be wired in parallel to each of the inputs. An exception is that if two or more channels of an amplifier are configured in software as a group or multi-way, the lowest local input channel number will be presented to all channels. For instance, if a VA-4030 is deployed with channels 2, 3 and 4 configured as a group or 3-way multi-way, local input 2 will be presented to outputs 2, 3 and 4. Page Active Relay Page Active Relays (PAR) are available on all amplifiers. Via the Page Active Relay connectors, one Form C (single pole, changeover) relay is presented per channel for the VA-4030 and VA-4030e. Similarly, two such relays per channel are presented for the VA-2060 and VA-2060e (relays operate in tandem). Each PAR connector is a six-way 3. 5mm pluggable screw terminal block. The PAR connections are labeled as follows: C: Relay Common NC: Normally Closed NO: Normally Open Page Active Relay: VA-4030e and VA-2060e 8 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e REAR PANEl Amplifier Output Connections CAUTION: All speaker wiring connections and output load selection should be made by qualified personnel and with the amplifier power removed. The 100V output requires Class 3 wiring. Please refer to a qualified electrician or other qualified person according to local codes. [. . . ] 1:1 or 3:1 channel failover is triggered by one of the following conditions: Heatsink fault (over temperature) Short circuit fault Channel failure fault ELD-1/speaker line fault if enabled in software The redundant channel may be wired in parallel to the existing speaker line or connected to a redundant speaker line. The primary amplifier module will resume control after the fault condition is cleared and the unit is re-powered. Channel-to-Channel Example: Single Wiring, Parallel Wiring and Redundant Speaker Topology 3:1 Failover Speaker Wiring 11 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e SPECIFICATIONS Vocia Amplifier 2060 / 2060e / 4030 / 4030e Message Memory: Network Audio: Network Connections: Analog Inputs: Nominal Input Range: Maximum Input Level: Equivalent Input Noise: Dynamic Range: Input Impedance: Phantom Power: Frequency Response: Signal to Noise Ratio: THD + Noise: Rated Output Power: VA-2060: VA-2060e: VA-4030: VA-4030e: Supported Loads: Low Impedance: Constant Voltage: Output Configuration: Output DC Offset: PAR Relays Form: Max Operating Voltage: Max Operating Current: 5. 625 MB 20-bits, 48kHz, 5-1/3 ms (fixed) RJ45 with shielded Ethernet cable (CAT5, CAT5e, CAT6 or CAT 7) (VA-2060e and VA-4030e) Per Channel -66dBu to 0dBu +24dBu (max Gain) >-125dbu >94dB 8k +48V DC 40Hz-20kHz +/- 2dB >88dB, unweighted <0. 5% 50Hz-100Hz <0. 3% 100Hz-10kHz 2x 60W RMS, total 120W 2x 60W RMS, total 120W 4x 30W RMS, total 120W 4x 30W RMS, total 120W 4, 8 25V, 70V or 100V Transformer Coupled (ground free) <100mV Single Form C contact 125V AC, 60V DC 100mA AC, 1A DC Power: AC (all amplifiers): DC (VA-2060e and VA-4030e): Continuous power rating Peak Power rating DC Range: Overall Dimensions: Height: Width: Depth: Weight: VA-2060: VA-2060e: VA- 4030: VA- 4030e: Compliance: 100V-240V AC, 50H 60 Hz Nominal 24V DC 60 Watts 150 Watts 18V-30V; <100mV Ripple 3. 25 in (82. 5mm) 19 in (483mm) 14. 2 in (360mm) 24. 7lbs (11. 2kg) 24. 9lbs (11. 3kg) 26. 0lbs (11. 8kg) 26. 2lbs (11. 9kg) FCC Part 15B (USA) EN 54-16 pending (Europe) UL 60065 and C-UL listed (USA & Canada) CCC pending (China) KC pending (Korea) C-Tick (Australia) RoHS Directive (Europe) 2002/95/EC (Europe) Environment Ambient Operating Temperature Range: 18-108 degrees F (-8 42 C) Ambient Intake: Humidity: 0 100% non-condensing Altitude: 0 10, 000 Feet MSL 12 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e blOCk dIAgRAM 4030e and 2060e Amplifiers 4030 and 2060 Amplifiers 13 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e CURRENT dRAW ANd hEAT OUTPUT VA-4030 and VA-4030e Specifications IDLE Total Output Power (Watts) 30 60 90 120 Channels Used 1 2 3 4 Input Power Watts 30 30 30 30 BTU /hr 102 102 102 102 1/8 POWER PINK NOISE Input Power Watts 36 41 47 54 BTU /hr 110 114 122 133 1/3 POWER PINK NOISE Input Power Watts 46 62 77 93 BTU /hr 123 143 160 181 FULL POWER SINE WAVE Input Power Watts 88 133 179 217 BTU /hr 198 242 304 331 VA-2060 and VA-2060e Specifications IDLE Total Output Power (Watts) 60 120 Channels Used 1 2 Input Power Watts 27 27 BTU /hr 92 92 1/8 POWER PINK NOISE Input Power Watts 38 50 BTU /hr 104 119 1/3 POWER PINK NOISE Input Power Watts 60 90 BTU /hr 136 171 FULL POWER SINE WAVE Input Power Watts 119 213 BTU /hr 201 317 14 VOCIA AMPlIFIERS VA-2060, VA-2060e, VA-4030, VA-4030e WARRANTY BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below. 2 If you notify BIAMP during the warranty period that a BIAMP Systems product fails to comply with the warranty, BIAMP Systems will repair or replace, at BIAMP Systems' option, the nonconforming product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP T-SERIES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP T-SERIES will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag