User manual BIAMP VOCIA CONTROL INTERFACE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP VOCIA CONTROL INTERFACE. We hope that this BIAMP VOCIA CONTROL INTERFACE user guide will be useful to you.

Lastmanuals help download the user guide BIAMP VOCIA CONTROL INTERFACE.


Mode d'emploi BIAMP VOCIA CONTROL INTERFACE
Download

You may also download the following manuals related to this product:

   BIAMP VOCIA CONTROL INTERFACE SHEET (293 ko)

Manual abstract: user guide BIAMP VOCIA CONTROL INTERFACE

Detailed instructions for use are in the User's Guide.

[. . . ] It will also commence when any fault is detected. The sounder will continue until the alarm or fault is reset. [. . . ] TheVoiceAlarmActiveoutputisprovidedtosignaltothefiredetectionsystemthat the Vocia system has been activated in emergency mode in response to an Alarm Input. A constant output denotes that an emergency message is playing. A pulsed output (1. 25Hz) indicates that an alarm is active but emergency messages have been silenced. TheGeneralFaultOutputisprovidedtosignaltothefiredetectionsystemthatthere is a fault in the Vocia system that could affect delivery of an emergency message. Connector Label Function Isolated Ground A1 A2 A3 A4 Rs Si Alarm 1 Input from CIE Alarm 2 Input from CIE Alarm 3 Input from CIE Alarm 4 Input from CIE Alarm Reset Input from CIE Alarm Silence Input from CIE Ground VA Voice Alarm Active Output to CIE GF General Fault Output to CIE The Voice Alarm Active and General Fault outputs pull low (to ground) when active. The outputs are monitored by the LSI-16 for open-circuit or short-circuit to ground or power supply and for over-voltage on the output pin (>35V DC). If incorrect conditions are detected a Fault is signaled. Output monitoring facilitatescompliancewithvoiceevacuationstandards. Formonitoringpurposesaload(maximum22k)mustbeconnectedbetween each output and a positive voltage source referenced to the LSI-16 Ground, at the far end of the connection to the CIE (i. e. AnLEDindicatorconnectedthrougharesistortoapositivevoltageattheCIEwillsufficeasamonitoringload. NotethattheLSI-16providesa10Vsourceatthe`10VOut'terminalontheLSI-16. Outputsmaybepulleduptothissource;howeverthe total current drawn from the source must not exceed 100mA. If an external voltage source is used for the outputs, it must not exceed 35V DC and in addition to the output loads, must also be connected to the LSI-16 `External Supply Over-voltage Monitor' input (refer to LSI-16 User Manual) for monitoring purposes. Due to monitoring constraints, it is not possible to use both the LSI-16 internal 10V source and an external source. 5 ReaR Panel Connections from External Devices for Fault Indications Thesecircuitsareprovidedonasinglefive-positionplug-inbarrierstripconnector. All Inputs are fully isolated from the CI-1 and LSI-16 internal circuits. The Isolated Ground provides a circuit return that is not directly connected to the CI-1 and LSI-16 Ground. These inputs allow the signaling of faults from external devices to the Vocia system so it may indicate and log faults that could affect emergency operation. These fault signals are typically derived from contact closures on external devices. [. . . ] Power Supply Connections Thesecircuitsareprovidedonasinglefive-positionplug-inbarrierstrip. Inputs are provided for two 24V power supply circuits to drive the LSI-16. This facilitates standards compliance by providing a means of redundant connections. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP VOCIA CONTROL INTERFACE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP VOCIA CONTROL INTERFACE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag