If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIOPTECHS DELTAT4CONTROLLER. We hope that this BIOPTECHS DELTAT4CONTROLLER user guide will be useful to you.

Lastmanuals help download the user guide BIOPTECHS DELTAT4CONTROLLER.


Mode d'emploi BIOPTECHS DELTAT4CONTROLLER
Download
Manual abstract: user guide BIOPTECHS DELTAT4CONTROLLER

Detailed instructions for use are in the User's Guide.

[. . . ] Delta T4 Culture Dish System Instructions Caution: Read Carefully Before Use! The System is comprised of three main components: a temperature controller, a stage adapter, and the Delta T Dish. It utilizes a new and improved technology that is much faster and more accurate than traditional peripheral stage warmers. The controller has a fast learning curve to anticipate changes in the dish temperature due to perfusion or surface evaporation while regulating temperature and compensating for entropy. The fast response capability of this system enables control features previously not possible with conventional peripheral systems. [. . . ] Temp Out is a voltage output direct from two instrument amplifiers reading the thermistors from channel A and B. The output from this socket is temperature /10. Left pin is channel A, center pin is channel B, and right pin is ground. Remote Setpoint is an analog input that allows the user to set the controllers setpoint from an external DC source. A DC voltage can be applied to the tip of this jack equal to temperature /10. When the jack is inserted into the controller it will automatically switch to the jacks value. When removed it will default to the setting on the front of the controller. Use for programming or cycling operating temperatures. Fixing Adjustment allows the user to adjust the voltage sent to the dish when the Fixing Switch is depressed. Fixing Switch is provided so that cells can be fixed on the stage of the microscope. It can also be used for heat shock experiments. The switch is recessed so that it is not actuated by mistake. This switch should be used when you intentionally want to overheat your cells. It provides a nearly instantaneous heat shock to the dish. TTL is a BNC connection used to change the mode of operation of the controller from a remote source such as a computer or slave from a shutter trigger. The default condition of the controller is dynamic control. To change to Imaging mode, apply a TTL logic high and hold to this BNC. The controller will remain in Imaging mode as long as the TTL condition remains high as indicated by the LED on the front panel. 3560 Beck Road · Butler, PA 16002 · Voice: 724-282-7145 · Fax: 724-282-0745 · E-mail: info@bioptechs. com · Web: www. bioptechs. com Instructions: 1. 2. Delta T4 Controller Operation 3. 7. 8. 9. Without any peripherals plugged into the controller, turn the unit on using the main on-off switch located on the rear panel adjacent to the power cord. The temperature display will read a number between -3. 7 and -4. 2. Press and hold the black button labeled "CALIBRATE" and make sure the display reads 25. 0°C. [. . . ] The sensitivity of the controller, 0. 1°C, coupled with the speed and intensity of the controller's response, may cause the coverslip to flex a detectable amount during narrow depth of field imaging. The controller is equipped with a circuit that bypasses the dynamic temperature control mode and permits you to temporarily send a constant DC current to the dish to eliminate the possibility of an abrupt change of energy occurring as might happen in dynamic mode. This prevents Zaxis displacement of the specimen during imaging. The controller can be switched from its default Dynamic control mode to Imaging mode by several means: 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIOPTECHS DELTAT4CONTROLLER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIOPTECHS DELTAT4CONTROLLER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag