User manual BOSCH PCI815B90A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BOSCH PCI815B90A. We hope that this BOSCH PCI815B90A user guide will be useful to you.

Lastmanuals help download the user guide BOSCH PCI815B90A.


Mode d'emploi BOSCH PCI815B90A
Download

You may also download the following manuals related to this product:

   BOSCH PCI815B90A annexe 1 (3551 ko)

Manual abstract: user guide BOSCH PCI815B90A

Detailed instructions for use are in the User's Guide.

[. . . ] This cooktop is for use with Natural Gas and Universal LPG PCL755FAU PCK755FAU PCI815B90A Robert Bosch Hausgeräte GmbH Carl-Wery-Straße 34 81739 München Cod. 9000298631 B Internet:: http://www. bosch-hausgeraete. de Dear customer, We would like to thank and congratulate you for your choice. This practical modern appliance has been made using materials of the highest quality, which have been put through the strictest of Quality Controls during manufacture and meticulously tested to ensure that they meet all of your cooking demands. We kindly ask you to read and follow these simple instructions in order to guarantee first-class results from the very start. [. . . ] For position of the inlet connection refer Fig. 1-1a. Use pipe compound or thread sealant, properly theaded pipes and careful assembly procedure so that there is no cross threading, etc. , which might cause damage or leakage. Make sure that all connections peformed are free of leakage. In either of the cases, do not move or twist the L-tube from its factory-set position. If for some reason, the L-tube should be twisted, it is necessary to make sure that this area is properly sealed. Make sure that all connections performed are free of leakage. The manufacture does not accept any liability for leakage on connections performed by the installer or if the L-tube is moved or twisted. Natural gas connection Universal LPG connection Pressure test point R 1/2" R 1/2" Pressure test point. 9 5 6 There are two ways to carry out the connection to the main gas line: A. The hotplate can be connected with rigid pipe as specified in AS5601 table 3. 1. Flexible Hose: If installing with a hose assembly, install with a hose assembly that complies with AS/NZS 1869 (AGA Approved), 10mm ID, class Bor D, no more than 1, 2m long and in accordance with AS5601. Natural Gas Burner Hourly Gas Consumption (MJ) 4, 0 6, 5 11. 5 14, 0 Injector size (mm) 0. 90 1. 18 1. 55 1. 70 Universal LPG Hourly Gas Consumption (MJ) 3, 25 6, 25 9. 5 13, 25 Injector size (mm) 0. 50 0. 67 0. 85 0. 97 Small Medium Large wok (Center or Left) Before conversion the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position. 1 Remove the trivets, burner caps and burner heads. 2 Change the injectors using a 7-mm socket wrench and be sure to tighten them down properly so that they are fully airtight. 3 Re-assemble the burner component parts in reverse order. NOTE: it is not necessary to adjust the primary air control on these burners. 7 mm 6 7 8 11 Minimum flame adjustment. 2 Remove the control knob from the valve spindle. 3 Apply pressure with the tip of the screwdriver to release the thread toward the tap's adjusting screw. 4 The adjustment screw is positioned at the rear lower section of the valve. 5 To adjust the minimum flame for N. G. replace the control knob onto the spindle, light the gas and turn the control knob to the small flame position. Screw the adjustment screw anti-clockwise to estabilish a minimum stable flame position. The flame should remain alight and not burn back to the injector when the valve is turned quickcly from `Full On' to the "Minimum flame" position and back a few times. To adjust the minimum flame position for ULPG the screw must be fully tightened down clockwise. Never dismount the valve shaft: in the event of damage, change the entire valve. 9 10 12 Operating instructions Burner locations 1 3 5 1 3 4 2 4 5 6 11 Burner ignition & control 12 1. [. . . ] . . . If the flame on the burners is not evenly distributed?·The burner components have not been assembled properly. ·The gas ports on the burners are dirty. · The burners may not be totally dry. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH PCI815B90A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH PCI815B90A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag