User manual BOWENS ESPRIT II 1500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BOWENS ESPRIT II 1500. We hope that this BOWENS ESPRIT II 1500 user guide will be useful to you.

Lastmanuals help download the user guide BOWENS ESPRIT II 1500.


Mode d'emploi BOWENS ESPRIT II 1500
Download
Manual abstract: user guide BOWENS ESPRIT II 1500

Detailed instructions for use are in the User's Guide.

[. . . ] Clear and frosted domes are also available as accessories for special applications. 2. Safety Notes · The Esprit 1500 must not be used in an environment where moisture or flammable vapour is likely to come in contact with the unit. · A cover glass dome should always be fitted during use. · A fire hazard exists if flammable materials are placed in close proximity to the flash tube, modelling lamp or glass dome when the unit is in use. · Switch off and disconnect supply before changing fuse, modelling bulb, flashtube, glass dome or reflector. [. . . ] Sync Socket: The standard quarter inch jack type socket on the rear panel of the unit (Fig. 1) may be used for direct connection to a camera set to `x' synchronisation. Two Esprit 1500 flash units may be connected together using a `y' connector. An Infra Red Receiver or Omnicell may also be plugged into this socket. 7. Flash Power Selection / Indication The Flash Power Selector Switch (Fig 2) sets the maximum flash power available. The power selected, 500, 1000 or 1500 Ws, is shown on the Digital Power Display (Fig. 2) and represents a coarse control range of 11/2 f-stops. The Flash Power Control (Fig. 2) provides a continuous adjustment within the range selected, over a five f-stop range from full to one thirty second (1/32) power. Rotating the Flash Power Control (Fig. 2) from full to half, half to quarter, quarter to eighth, eighth to sixteenth and sixteenth to thirty second gives a reduction in output equivalent to 1 f-stop for each step. The total control range using the Flash Power Control and Flash Power Selector Switch is 61/2 f-stops. The auto-dump feature enables lower flash powers to be selected without requiring the unit to be flashed first to dump the higher power. The digital display blinks during the power dump to provide an indication of the status. 8. Modelling Lamp Control With the Modelling Lamp Control Switch (Fig. 1) in the central position the modelling light is `OFF'. With the switch set to `Intermittent' the modelling light will go out when the unit is flashed and come back on when the unit comes to ready. This enables -4- Bowens Esprit 1500 Operating Instructions. the photographer to see from the camera position that all Esprit units in use have fired. With the switch set to `Continuous' the modelling light remains `ON' all the time. The modelling light may be varied in ratio with the flash power output by aligning the indicator line on the Modelling Lamp Control (Fig. 2) with that of the Flash Power Control (Fig. 2). Audible `Ready' Confirmation Set the Sounder Switch (Fig. 1) to `ON' to give a short beep when the unit comes to ready, to provide an audible `Ready' confirmation. Fuse The modelling and flash circuitry is protected by a single 10 amp (F) 20mm fuse mounted on the rear panel (Fig. 1). Never replace the fuse with one of a different rating. As the fuse may blow when the modelling lamp fails always check the fuse when replacing the lamp. A spare fuse is supplied in the fuse holder. Always switch OFF the Esprit 1500 before changing the fuse or lamp. Fitting / Removing A Reflector A range of reflectors is available for the Esprit 1500. To fit, slide the neck of the reflector over the front of the unit. Align the three pegs on the reflector with the three slots in the retaining ring, press down and turn clockwise to lock. [. . . ] Press down evenly until all the plugs and sockets are fully engaged. Pass the trigger wire through the hole in the trigger terminal tag and wind around the tag, ensuring that the wire does not touch the metal top hat. Refit the glass dome as described in section 12. Discard the old flash tube safely using the packaging from the new tube. FIG. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOWENS ESPRIT II 1500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BOWENS ESPRIT II 1500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag