User manual CADDX NX8-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CADDX NX8-E. We hope that this CADDX NX8-E user guide will be useful to you.

Lastmanuals help download the user guide CADDX NX8-E.


Mode d'emploi CADDX NX8-E
Download
Manual abstract: user guide CADDX NX8-E

Detailed instructions for use are in the User's Guide.

[. . . ] SECURITY SYSTEM NOTES Installing/Service Company _________________________________ For Service Call __________________________________________ Central Station ___________________________________________ Duress Code ____________________ FUNCTION CODES Function Code Controls Function This system is Y is not Y partitioned. EMERGENCY ACTIVATION KEYS (check if enabled) Y Fire Y Auxiliary Emergency Y Police PROGRAMMED FUNCTIONS Y Cancel Alarm Y Change Partitions Y Chime Y Communicator Test Y Forced Arming (8) Y Group Bypass (8) Y Quick Arm (8) Y Re Exit Y Siren Test (8) These features should not be enabled on UL listed systems. ENTRY / EXIT DELAY TIMES Exit Delay Time __________ Secondary Exit Delay Time ________ Entry Delay Time _________ Secondary Entry Delay Time _______ ZONE DESCRIPTIONS Y Abort Delay (8) Y Auto Bypass (8) Y Auto Instant Y Battery Test 01 _______________ 02 _______________ 03 _______________ 04 _______________ 05 _______________ 06 _______________ 07 _______________ 08 _______________ 09 _______________ 10 _______________ 11 _______________ 12 _______________ 13 _______________ 14 _______________ 15 _______________ 16 _______________ 17 _______________ 18 _______________ 19 _______________ 20 _______________ 21 _______________ 22 _______________ 23 _______________ 24 _______________ 1 THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION. ALL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET. FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT WORKING PROPERLY. [. . . ] · The instant light will illuminate indicating that the entry/exit doors have no entry delay. Step 4 USING THE QUICK ARM (Optional, see page 1) The Quick Arm feature may be used if it is enabled. Quick Arm will allow the user to arm the security system in the AWAY mode by pressing the [EXIT] key, or arm in the STAY mode by pressing the [STAY] key. This feature is used for ARMING ONLY, and will not disarm the security system. This is ideal for a maid or baby sitter code, etc. CHANGING MODES WHILE SYSTEM IS ARMED S Pressing the [STAY] key will turn on/off (toggle) a delay on entry/exit doors and turn on/off (toggle) the instant light. S (Optional) Press the [BYPASS] key at this time to turn on/off (toggle) all designated interior zones. S (Optional) When armed, pressing the [EXIT] key will start the exit delay, enabling you to leave the building. IMPORTANT The instant light needs to be off at this time if you plan on re-entering the building; otherwise you will create an alarm. You may restore an entry delay by pressing the [STAY] key again. DISARMING THE SYSTEM When you enter the protected area through one of the designated Entry/Exit doors, the keypad control will sound a continuous tone for the duration of the entry delay time, or until you enter a valid code. The red armed light will go off and the tone will stop. If a valid code is not entered before the end of the entry delay, an alarm will occur. (NOTE: If the red armed light is flashing during the entry delay, the alarm system has been activated in your absence. Leave the building immediately and call your alarm company and/or the police from a safe location. ) 8 CANCEL / ABORT FEATURE (Optional, see page 1) The cancel light will flash during an abort delay time. If a code is entered followed by the [CANCEL] key while this light is flashing, all abortable reports will stop the communication process. Entering a code followed by the [CANCEL] key during or after an alarm report to the central station will cause the cancel light to come on. It will stay on until the central station has received the cancel report. BYPASSING ZONES If you wish to bypass one or more zones, this must be done while the system is in the disarmed state. The following steps are used for bypassing zones: Step 1 Step 2 Step 3 Press the [BYPASS] key. Enter the digits indicating the zone you wish to bypass. (Example: Press the [1] key for zone 1, press [1] - [0] - [6] for zone 106. ) Press the [BYPASS] key again. The corresponding zone light will illuminate indicating the zone has been bypassed. Repeat steps 3 and 4 for any other zone(s) that need to be bypassed. Press the [BYPASS] key again -or- press the [#] key to exit the Bypass Mode. [. . . ] Note: This fault is global in nature and will affect all partitions of a multi-partition system. To exit the Service Light Mode - press the [#] key. 15 LIGHT 1 EMERGENCY EVACUATION PLANS An emergency evacuation plan should be established for an actual fire alarm condition. For example, the following steps are recommended by the National Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CADDX NX8-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CADDX NX8-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag