User manual CANDY PG750

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CANDY PG750. We hope that this CANDY PG750 user guide will be useful to you.

Lastmanuals help download the user guide CANDY PG750.


Mode d'emploi CANDY PG750
Download
Manual abstract: user guide CANDY PG750

Detailed instructions for use are in the User's Guide.

[. . . ] PIANI COTTURA ISTRUZIONI PER L'USO FR TABLES DE CUISSON NOTICE D'EMPLOI ES ENCIMERAS INSTRUCCIONES PARA EL USO GB IE HOBS USER INSTRUCTIONS PT PLACAS DE INSTRUES DE UTILIZAO IT Tab. 1 BUILT IN HOBS Burners/hotplates Type / reference Flame failure device Fish burner PES Double ring burner Ultra rapid burner Semirapid burner Rapid burner Griddle 174x160 mm Griddle 229x379 Electric plate 80 Electric plate 145 Electric plate 160x265 mm Installed gas Type/Power: G20 20mbar* (METHANE) G30 28-30mbar (GPL) Installation class Voltage/Frequency V/Hz Electrical imput power Electronic ignition Product dimension WXD (mm) 4 gas 4 gas 1 electric - / yes DC 110 mm UR 110 mm SR 51 mm R 71 mm - / yes 3 gas 1 electric - / yes - / yes - / yes - / yes - / yes 4 gas 5 gas 5 gas 5 gas 4 gas 1 electric - / yes - / yes 4 gas PE PE PE yes yes yes yes yes yes yes yes yes * Manufacturer setting IE cat. II2H3 + A B C D This appliance has been designed for non-professional, i. e. domestic, use. 38 GB IE UR - DC E R R R PES R F SR SR SR SR G R BIST. [. . . ] (See the instructions in the following paragraphs). connection to the mains gas supply or gas cylinder should be carried out according to the relevant national standards, after having checked that it is regulated for the type of gas with which it will be supplied. If it is not correctly regulated follow the instructions in the paragraph entitlet Adaption for different types of gas. For liquid gas (cylinder gas) use pressure regulators which comply with the relevant national standards. N. B. : for safe operation, economic use of energy and to ensure greater durability of the appliance, make sure that the supply pressure conforms with the values shown in the table on page 45. Use only pipes, washers and sealing washers which comply with the relevant national standards. When connecting the hob to the gas supply via use of flexible hoses please ensure that the maximum distance covered by the hose does not exceed 2 metres. N. B. : carry out a final check for leaks on the pipework using a soapy solution. Also, make sure that the flexible pipe cannot come into contact with a moving part of the cabinet (eg, a drawer) and that it is not situated where it could be damaged. IE GB 43 To prevent any potential damage to the hob please carry out the installation following this sequence: GB IE 1/2 GAS CONICAL A) As illustrated, assemble parts in sequence: A) fixed pipe B) washer C) Elbow fitting with tapered thred connection 2) Tighten the joints with the Spanners, remembering to twist the pipes into position. 3) Attach fitting C to mains gas supply using rigid copper pipe or flexible steel pipe. Please note Some models are equipped with both conical and cylindrical connectors for gas supply. Please select the type which is correct for the supply concerned. Fig. 5 A Cylindrical (but connector) B Tapered thread conical ADAPTING THE HOB TO DIFFERENT TYPES OF GAS To adapt the Hob for use with different types of gas, carry out the following instructions: -- remove the grids and burners -- insert the hexagonal spanner (supplied) into the burner support (Fig. 6) -- unscrew the injector and replace it with one suitable for the gas to be used (see Table of gas consumption) -- carry out regulation of the burner. Hexagonal spanner Fig. 6 44 GB IE Table of gas consumption G20/G25 G30 G31 G20 20mbar G30 29mbar G31 37mbar 1W = 0, 860 kcal/h G25 25mbar G20 X dimension according to Gas type G30 G25 G31 Working burner large medium maxi double ring fish gas jet gas jet 1/100 mm 1/100 mm 120 80 93 61 2x94 2x65 2x94 2x65 2x94 2x65 STD. Dim kW 2, 65 1, 5 3, 3 3, 3 3, 3 l/h G20 252 143 314 314 314 g/h G30 193 109 238 238 238 g/h G31 189 107 236 236 236 Qn kW 2, 5 1, 45 3, 1 3, 1 3, 1 l/h G25 277 161 343 343 343 min. Dim kW 0, 65 0, 38 0, 9 0, 9 0, 9 reg. air 5 mm 7 mm 15 mm 15 mm 15 mm SETTING OF THE GAS BURNERS When the jets have been changed it is necessary to set the correct air gap by keeping to the setting "X" as shown in the table " gas consumption" fig 7. Warning the value of ` X ` setting varies in relation to the size of gas burner and type of gas chosen. A good flame must be of medium length (fig. 8B), excessive air will cause the flame to be short and with sharp colour (fig. 8C): in this case it is necessary to extend out the tube for the air setting from the burner body, if there is insufficient air the flame will appear weak and long (fig. 8A): in this case push the tube of the air setting back into the burner body. To adjust the air setting tube loosen the retaining screw. Once the air is correctly set secure the screw over the tube ( fig. 7). For dimensions X see table of gas consumption BURNER FIXING SCREW SMALL MEDIUM LARGE BURNER CAP AIR REGULATION SCREW DOUBLE RING MAXI FISH Fig. [. . . ] Only pans which have smooth flat bases should be used on the electric hotplates. The size of the pan should be as close as possible to the diameter of the hotplate, and never smaller (see Fig. The base of the pan should be dry and spillages should be avoided. Empty pans should not be left on the plates, nor should the plates left switched on without a pan. YES NO NO NO NO Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANDY PG750

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CANDY PG750 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag