User manual CANNON FITZROY IN-BUILT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CANNON FITZROY IN-BUILT. We hope that this CANNON FITZROY IN-BUILT user guide will be useful to you.

Lastmanuals help download the user guide CANNON FITZROY IN-BUILT.


Mode d'emploi CANNON FITZROY IN-BUILT
Download
Manual abstract: user guide CANNON FITZROY IN-BUILT

Detailed instructions for use are in the User's Guide.

[. . . ] Consumers are responsible for service person's travel outside normal service areas (approximately seventy (70k) radius from the nearest Cannon dealer's location), local cartage, and normal maintenance as described in this manual. Any product subjected to misuse, abuse, negligence, accident or alteration will have its warranty voided. The defacement of serial plate will have it's warranty voided. If installation is not carried out in accordance with manufacturer's instructions, this warranty may be void. [. . . ] Remove the lower front cover, see figure 16. A 10 Amp wall socket needs to be located within 1. 5m of the heater. If using a power point in the chimney, route the plug and cord through cord access at lower LH side of rear panel. Ensure that the grommet is located over the edges of the access hole. Hard (fixed ) wiring connection is to be carried out only by a qualified electrician. 14 7. Remove the front glass surround by holding it firmly on either side and pulling it towards yourself, see figure 15. 15 16 8. Remove the lower front cover by unscrewing two M5 screws through the air intake slots, see figure 16. If unit is fitted with supply flexible cord ensure that the cord cannot be trapped when the heater is installed. 17 9. Disconnect the switch loom connector from the loom plug. 10. To remove the front heater surround undo two s/t screws (one either side) from the bottom flange of the front panel as indicated in figure 18. Refer figure 29 . 29 16 Advise the user in the operation of the heater 18. Avoid installing into large volume fireplaces and chimneys without any flue. Allow for the use of a flue in these applications. We recommend cleaning or sweeping of the chimney and fireplace before the installation of a new heater. There must be a good seal around the heater, gas piping and electrical cable rear entry to stop any leakage of combustion products. Do not use adhesives or silicone sealant, the heater must be able to be easily removed if necessary. Install a chimney plate and cowl to the chimney opening using weatherproof mortar to common building practice. Remove any curved firewall that slopes too far forward to the fireplace opening if it causes restriction to the flue path above the heater flue outlet. Make sure that the heater is fully commissioned and be certain to conduct a test of the integrity of the flue operation, taking into account any influences created by rangehoods, exhaust fans, central heating, etc. To avoid any unnecessary delays and inconvenience to your customer, please contact our technical services department on 1300 727 421 if the installation is unusual or you have concerns with the installation and/or heater operation before installation. Any service requests resulting from incorrect installations are not covered by our warranty conditions and these calls will result in charges, usually to the end user, so please ensure that the installation and commissioning is satisfactorily carried out before calling for any warranty service. Please make sure that your customer is fully instructed on how to operate the heater. 19 Service instructions (Do not modify this appliance) General 1. [. . . ] A positive check is to use a jumper wire and connect one end of the earth and hold the other end with insulated pliers 4mm from the spark generator on the module. If there is no spark to earth then change the module. Check the spark ceramic insulator for signs of cracks. 5. Confirm spark is produced when heater is turned on. 6. If no spark being produced. 7. Spark is being produced but not at burner. 22 8. Sparks, ignites on low flame then extinguishes after 10 seconds. Continues to spark during flame presence. · Check that the wall socket to the appliance has correct polarity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CANNON FITZROY IN-BUILT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CANNON FITZROY IN-BUILT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag