User manual CARRIER 00DCG000003400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CARRIER 00DCG000003400. We hope that this CARRIER 00DCG000003400 user guide will be useful to you.

Lastmanuals help download the user guide CARRIER 00DCG000003400.


Mode d'emploi CARRIER 00DCG000003400
Download
Manual abstract: user guide CARRIER 00DCG000003400

Detailed instructions for use are in the User's Guide.

[. . . ] The large operating map of the scroll compressor allows high temperature operation, up to 145°F [63°C] leaving load water temperature even at 32°F [0°C] entering source water temperature. The combination of a coaxial (tube-in-tube) heat exchanger for the source (ground loop) side and a brazed plate heat exchanger for the load (heating/hot water) side provides very high efficiencies. Integral controls for hydronic heating and domestic water heating avoid the need for external microprocessor-based controls for outdoor temperature reset, warm weather shutdown, staging and other controls. The 50YEW has an extended range refrigeration circuit, capable of ground loop (geothermal) applications as well as open loop (well water) applications. [. . . ] Fault lockout enables emergency heat and prevents compressor operation until thermostat or circuit breaker has been reset. · 10-year limited warranty on major refrigerant circuit components, Optional extended warranties available. · AHRI/ASHRAE/ANSI/ISO 13256-2 certified. · US EPA "Energy Star" compliant. Options & Accessories · Full Condensing Hot Water Generation With Internal Secondary Heat Exchanger and Potable Water Circulating Pump. · Factory Installed "Load" and "Source" Pumps. · Factory Installed Expansion Tanks. · Cupro-Nickel Source Water Coil. · Extended Labor Allowance and Service Warranty. Residential Products Technical Guide 50YEW 197 GT-PW Water-to-Water (50YEW) Series 50YEW Water-To-Water Series Features 1 2 3 4 5 Euro-Style Cabinet For Attractive Look High Temperature Scroll Compressor Rugged Coaxial "Source" Heat Exchanger Close Approach Temperature Brazed Plate Stainless Steel "Load" Heat Exchanger Optional Full Condensing Hot Water Generation With Internal Secondary Heat Exchanger and Potable Water Circulating Pump Optional Factory Installed "Load" and "Source" Pumps with expansion tanks Fully Insulated Water and Refrigerant Lines Fully Insulated Compressor Section Powder Coated Galvanized Steel Cabinet and Front Access Panel For Long Life, Taupe Metallic Large Backlight User Interface Built-In Programmable Controller With Outdoor Temperature Reset and Warm Weather Shutdown Dual level compressor isolation and discharge muffler for ultra quiet operation Hinged Front Access Door and Three Removable Panels For Ease of Installation and Service 12-Point Terminal Strip For Ease of Low Voltage Wiring 5 6 11 7 14 6 4 1 7 8 9 3 10 11 2 12 12 13 9 10 13 14 8 50YEW 198 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems Model Key 1 2 3 456 7 8 9 10 11 12 50 Y E W 0 1 0 A W C 3 1 1 Prefix YEW = Puron High Temperature Heating Only Water-to-Water Packaging Revision Level 1 = Current 1 = Single Pack, Domestic Residential Series Unit Size 010 (10kW) Voltage 3 = 208-230/60/1 Hydronic Options A = No Pump B = Load Pump w/Expansion Tank C = Load Pump & Source Pump(s) w/Expansion Tanks Water Coil & DHW Options C = Copper Source & Braze Plate Load, No DHW D = Copper Source & Braze Plate Load, DHW w/Sec. hx & pump* N = Cupro-Nickel Source & Braze Plate Load, No DHW P = Cupro-Nickel Source & Braze Plate Load, DHW w/Sec. hx & pump* Controls W = CXM Y = CXM w/VSFP *When digit 9 = "D" or "P, " digit 7 cannot be A. " Residential Products Technical Guide 50YEW 199 GT-PW Water-to-Water (50YEW) Series Rated Equipment Performance & Efficiencies 60 Hz (I-P) Units Ground Loop Heat Pump Heating Model Indoor 86/95°F Outdoor 32/27°F Capacity Mbtuh 50YEW010 THW010 32. 6 COP 4. 2 Ground Water Heat Pump Heating Indoor 86/95°F Outdoor 50/45°F Capacity Mbtuh 42. 6 COP 5. 2 Indoor 104/113°F Outdoor 32/27°F Capacity Mbtuh 30. 8 COP 3. 3 Indoor 104/113°F Outdoor 50/45°F Capacity Mbtuh 39. 9 COP 4. 1 Indoor temperature is also called "Load;" outdoor temperature is also called "Source. " Numbers shown with "/" indicate entering/leaving water temperatures. The interior shall be insulated with 1/2" [13mm] thick, multi-density, foil-backed coated glass fiber. Three access panels shall be provided and shall be removable with piping in place. The internal component layout shall provide for major service with the unit in place for restricted access installations. The units shall have an insulated compressor section to minimize the transmission of compressor noise. Refrigerant Circuit All units shall contain Puron® (HFC-410A) sealed refrigerant circuit employing a hermetic motor-compressor, thermal expansion valve, coaxial tube water-to-refrigerant Source heat exchanger, brazed plate Load heat exchanger, compressor discharge muffler, 100% molecular sieve filter drier with XH-11 desiccant, and service ports. An optional Domestic Hot Water mode shall be available. Compressors shall be scroll type designed for heat pump duty and shall be double isolated from the cabinet with two sets of compressor mounting hardware. Compressor motors shall be single-phase PSC with internal over load protection. The coaxial water-to-refrigerant heat exchangers shall be designed for close approach temperatures and be constructed of a convoluted copper (optional cupro-nickel) inner tube and steel outer tube. The brazed plate heat exchanger shall be designed for close approach temperatures and shall be constructed with stainless steel plates. The thermal expansion valve shall provide proper superheat over the entire fluid temperature range with minimal "hunting". [. . . ] A circuit breaker protected 75VA transformer shall be employed. Units shall have knockouts for entrance of low and line voltage wiring. Piping Source/Load supply and return water connections, as well as Domestic Hot Water supply and return connections shall be FPT (Female Pipe Thread) copper fittings and shall be securely mounted flush to the cabinet allowing for connection to an MPT (Male Pipe Thread) fitting without the use of a back-up wrench. All Source water piping shall be insulated to prevent condensation at low liquid temperatures. 50YEW 214 Carrier : Turn to the Exper ts. Carrier Geothermal Heat Pump Systems Accessories & Warranty Accessories & Options Hot Water Mode Option An optional mode to provide domestic hot water shall be provided. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CARRIER 00DCG000003400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CARRIER 00DCG000003400 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag